Get complete information related to latest Relay Card Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Card Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Card Tenders.
Tender For supply of prosense relaycard to jk exim (p) ltd part no. jk-fsd-1125 for automatic smoke/fire detection with alarm system (fds) in railway coaches as per rdso specification no.rdso/2008/cg-04. (rev-6). [warranty period: 30 months after the date of delivery ]
Tender For rechargeable coach backing siren equipment. 12-volt with minimum 8 hrs. run time, four type siren noise with 12-volt buzzer, red indicator 6v and 12 v with charging auto cut off power supply for charging battery relay for ac/dc, charging indication and suitable charger, 15 x15x 7 cm metal body, 2 yearswarranty [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of
Tender For supply of auxiliary protection time lag relay (for q118 application) as per clw specification no.clw/es/r-27 alt-z or latest. [ warranty period: 30 months after the date of delivery ]
Tender For auction sale of depot ferrous scrap - 12264ms26b, 98011625, quantity- 44.580 mts scrap condemned unserviceable ms angles and channels, ismc,ismb cribs, bonds, binding strips, suspension angles, ismb cc cribs rounds, unipole channels, tie bars and flats, foot over bridges, channels, angles, angle ladders relay racks, ct racks, sliding channels, dismantled cut pieces of angles, channels, girders, with or without attachments of ms plates, sheets, nuts and bolts, loose plates sheets of sorts and sizes, with or without attachments including pieces of ms rusted thin clips and rounds, note- gas cutting permitted to facilitate loading. note- private crane permitted to facilitate loading. location- bin.no.264, left side of road no 2, hsn code- 72044900. gst- 18 percent. note- delivery on actual weighment basis only. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery.
Tender For auction sale of depot ferrous scrap - 12112ms26b, 98050011, quantity- 79.435 mts. scrap condemned unserviceable ms-ci signal interlocking materials consisting of levers, rods, ms campus rollers of molb, molb weights, molb booms, signal tubular post, roller trestle, stop boards, 33 mm rods, signal arms, gi and ms wires, lc gate pipes, gate structures, ladders, angles, channels, joists, roller stands, electric poles, cable termination box, direct type lever frame, sa 1914 type trays, sm slides, ssi termination rack, control panels, signal booms, boom locks, cable termination rack, adjustable crank, e type lock, cable marker, ground connection rods, fuse unit, power racks, cam path, gear box, signal reverser, ground lever frame, molb, eolb pedestal, telecom charger body, wire adjustment screws, molb compass roller, gate weights, cls tubular post, surface base, nuts, bolts, rounds, turnout wheels, eye joints, point machine covers, clamps, signal buckets, pulleys, d.w.diversion wheel, gate control panel, calling on unit, gear box assembly with clutch, winch, offset brackets, h.p lock, chequered plates, ptb, location boxes, rkt, axle counter coil fixing plate, shunt signals, route arm, route [1 way, 2 way, 3 way and 4 way], ib hut cut parts, ms electrical point detector, junction type route indicator, route indicators, structures, casing structures, ci bases, gear wheels, flats, cable termination base, u- brackets, ci weights of booms, fabricated posts, cls 2, 3 and 4 aspect units, trestle, sge block instrument, y-crank, stands for wheel tension measuring devices of d.w clutch, lock bar clips, drum clock, ec boxes, relay racks, tlj boxes, foundation shoe, ekt, pd clamps, galaxy stand, meeting posts, signal lamp structures, point rods and other similar signal and interlocking scrap material of sorts and sizes, with or without attachments including negligible nf attachments. note- nf attachments are approximately 2 percent of lot quantity. location- bin no- 112, right side of road no- 1. hsn code- 72044900. gst- 18 percent note: private crane permitted for loading purpose. note- delivery on actual weighment basis only. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery as per motor vehicle act 1988.
Tender For supply of amc preventive visit atleast two times a year lump sum estimated unit cost , rewinding of motor of pm10 sampler , rewinding of pump of pm2.5 sampler , change of washer of pump of pm2.5 sampler , change of one no. of patti of pump of pm2.5 sampler , change of one no. of metal ring of pump of pm2.5 sampler , replacement of motor of pm10 sampler , replacement of pump of pm2.5 sampler , replacement of one no. of manometer of pm10 sampler , replacement of water tank of pm10 sampler , replacement of silicone pipe in pm10 sampler , replacement of one no. of data logger of pm2.5 sampler , replacement of one no. of downpipe of pm2.5 sampler , replacement of one no. of 6 mm pu pipe of pm2.5 sampler , replacement of one no. 8 mm pipe of pm2.5 sampler , replacement of one no. of wins impactor of pm2.5 sampler , replacement of one no. of inlet cap of pm2.5 sampler , repair of one no. of stablizer change of relay of dust samplers , repair of one no. of stablizer change of display card of dust samplers , replacement of one no. of stablizer , repair of time totalizer of dust samplers , change of door lock of housing assembly of dust sampler , replacement of toggle switch , replacement of ac socket , replacement of fushe holder , replacement of digital timer , replacement of i bolt set , replacement of glind , replacement of hinges , replacement of nut bolt screw steel , change of glass impinger , calibration respirable dust sampler pm10 sampler , calibration of pm2.5 sampler , calibration of gaseous sampling