Web Analytics Made Easy - StatCounter

Relay Scrap Tenders

Get complete information related to latest Relay Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :43356404 Due date: 17 Jan, 202617 Jan, 2026 NA
Tender For supply of earth fault , phase failure & uv/ov relay , phase preventer

Central Government And Public Sector

CTN :42951183 Due date: 08 Jan, 202608 Jan, 2026 NA
Tender For corrigendum : supply of dc rotor earth fault relay bender -isometer iso685-d

CTN :42996771 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of acb testing calibration service , ammeter voltmeter meter calibration and testing , thermal relay testing and calibration , earth fault relay testing , over current relay testing , auxilliary relay testing , instantaneous relay testing , ht cable ir testing , lt cable and motor ir testing , rubber mat testing , vcb testing , calibration of multimeter , calibration of clampmeter , calibration of earth tester , calibration of megger , calibration of lux meter , calibration of fluke ir thermometer , battery load test 16 cells , battery load test 32 cells , transformer oil , transformer oil tesing and filtration , tramsformer ir pi test , tramsformer oti wti calibration , tramsformer dfra test , tramsformer partial discharge test , tramsformer sfra test , tramsformer tan delta test , transformer vector group test , transformer polarity test , dga test of transformer oil ) /bid number: gem/2025/b/6950854 * /dated: 01-12-2025 & & / bid document1 / 26

State Government

CTN :43312385 Due date: 02 Jan, 202602 Jan, 2026 3.30 Lacs
Tender For tender for repair and replacement of equipment at 33/11kv s/stn 2x5 mva sub -station dalhousie under electrical sub-division dalhousie. - 33/11kv s/stn 2x5 mva sub -station dalhousie under electrical sub-division dalhousie., complete overhauling of 4 outgoing feeder breaker trolley with repair & replacement of 4 nos. spring charge motors, tripping & closing coils , limit switch, indication bulb and other minor spare parts like lock spring, grease complete in all respect to make smooth opeartion of breaker., providing and fixing declo make spring, charge motor with gearbox and limit switch in 4 nos. breakers., providing and fitting of overcurrent & earth fault relay ashida 141c or cg 14n, providing & fixing of 3 mm 10% thick non-metallic, anti-static, fire retardant, low temperature resistant, acid/alkali resistant, high breakdown voltage min 33kv epoxy electric floor coating. coating conforming to class-c is 15652:2006. shall properly bond to the surface., providing & fixing digital ampere meter 30vdc rish dpm or equivalent.

State Government

CTN :43312403 Due date: 02 Jan, 202602 Jan, 2026 2.55 Lacs
Tender For tender for repair and replacement of equipment at 33/11kv s/stn 2x1.6 mva sub -station sihunta under electrical sub-division sihunta. - 33/11kv s/stn 2x 1.6 mva sub -station sihunta under electrical sub-division sihunta., complete overhauling of 33kv abb make outdoor breaker with repair/ replacement of various spare parts i.e. limit switch, cam,latch,spring, change, motor etc. complete in all respect., complete overhauling of 33kv abb make incoming 1 outdoor breaker with replacement of operating mechanism. tnc switch, limit switch etc. complete in all respect., rectifiaction of wiring in 2 no. c & r panel with rewiring and replacement of tnc switch etc. complete in all respect., providing & fixing of overcurrent and earth fault relay cgl make., providng and fixing of 11kv vaccum intetrruption in 11kv cgl make vcb breaker trolley., providing & fixing of 24 watt led street light with clamp fittings.

corporations/Associations/Others

CTN :43260466 Due date: 05 Jan, 202605 Jan, 2026 NA
Tender For supply of 1 no. of numerical directional overcurrent/ earth fault relay as per specification to coimbatore operation circle

Central Government/Public Sector

CTN :42956361 Due date: 02 Jan, 202602 Jan, 2026 61.87 Lacs
Tender For corrigendum : provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(a

Central Government And Public Sector

CTN :43324932 Due date: 16 Jan, 202616 Jan, 2026 NA
Tender For corrigendum : supply of earth fault relay test unit for 3-phase locos. details as per annexure (enclosed).

CTN :43306573 Due date: 02 Jan, 202602 Jan, 2026 NA
Tender For supply of supply of electrical spares d d cont,ele,power,220vac,mnx32 3p,l and t , cont,ele,230v,mnx18 , rly,ele,bimetal,6-10ap direct,mn2 r3,l and t , cont,ele,power,220vac,mx0 40e 4no,l and t , sply and fixg of add on block 2no 2nc , no start push button, flp , flp nc stop push button , no, nc button , elcb,lexic rccb,legrand 240v,40ap,2p , elcb,lexic rccb,legrand 400v,40ap,4p , sup and inst of cable joint kitdim 4cx25mm2 , sup. of lugs for 10 sqmm, cu , sply and fixg of lug cu,16mm2 , sply and fixg of lug cu,25mm2 , 35sqmm connector bolt and nut , sply and fixg of led driver , sup and fix of flood lgtled,100w,driver , sply and term of cableflp gland end,19mm , sply and term of cableflp gland end,25mm , 1c x 10sqmm , compound,silica gel breather cap 0. 5-1. 5 , sup digital multimeter , supply 40w lights , earth fault module , ht 3 m tape insulation tape 2 , screw driver set taparia , photo sensor inductive , a1d1 timer , siemens 38a contactors , relay base,pyf14a yokogawa , tnc switch ht panel , nose plier,cuti,125mm , side cutting plier,cuti,165mm , sp mcb 6 10 16 20 25 32 amps electrical , sply and fixg of mcb raring 20a,240v,1p , flp hooter,intrinsically safe vol 230vac , hand gloves,11kv,rbr insulation,is 4770 , hand gloves,1. 1kv,rbr insulation,is 4770 , ht fuse wire , 11kv dropout fuses , clamp meter,0 to 24 ma dc fluke megger yoko , provd hdmi to vga convertor , 1. 5sqmm green polycab earthing cable , switch,network , bolt,allen head,ss,6mm mc,11by2in , bolt,allen head,ss,8mm mc,1-1by2in , flp pressure switch 1. 5-10kgcm2 , flp pressure switch 2. 520kgcm2 , 4 pole 3 way selector switch , pressure switch , flp push button reverse forward , flp push button station , auto drain valves electropneum , flp jb 4 way 4 inch , street lights crompton , flp solenoid coil set with base , led indication bulbs 110 v ryb coller , 230 vac 1 inch threding led indicators r , simens38 40 to 57a olr , ring spanner set taparia , taparia l ankey set , 2. 5 sqmm cu sleave type lugs , 16 sqmm pin type cu lugs , 25 sqmm pin type cu lugs , digital insulation megger1000v 2000 ohm , 3tf47 simens contctors , flp limit switches baliga make , flp lights , flp jb 4 way 8 inch

CTN :42970686 Due date: 01 Jan, 202601 Jan, 2026 NA
Tender For corrigendum : supply of earth fault relay educational kit (q3)
 Loading, Please wait...

Connect us via What's Up