Get complete information related to latest Relay Station Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Station Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Station Tenders.
Tender For supply of voltage sensing pcb for 300kw ucr - aw 205 840 303-2 , static switch controller pcb for 300kw ucr - aw 205 800 293-1 , smps pcb for 300kw ucr - aw 205 800 259 , current amplifier pcb for 300kw ucr - aw 205 840 243 , alarm annunciation pcb for 300kw ucr - aw 205 840 281-1 , protection setting pcb for 300kw ucr - aw 205 840 355 , igbt gate drive pcb 15v for 300kw ucr - aw 205 840 265- 2 , controller card for 300kw ucr - aw bgf pe 061 0151 , power supply card 440v for 300kw ucr - aw bgf pe 040 0098 , dac pcb for 300kw ucr - aw 205 840 320 , relay pcb 12v for 300kw ucr - aw 205 840 310 , power supply card 360v for 200kw ucr - aw bgf pe 040 0098 , voltage sensing pcb for 2x30kva ac ups - aw 205 840 303-2 , controller pcb for 2x30kva ac ups - aw bgf pe 061 0151 , igbt gate drive pcb 15v for 2x30kva ac ups - aw 205 840 265-2 , earth fault pcb 12v for 2x30kva ac ups - aw 205 840 268 , tft interface board for 2x30kva ac ups - sd 105 010412, aw 205 840 375 , fuse fail pcb 12v for 2x30kva ac ups - aw 205 840 268 , relay pcb 12v for 2x30kva ac ups - aw 205 840 310 , ss gate driver card for 2x30kva ac ups - aw 205 840 324 , smps pcb - 360vdc for 2x30kva ac ups - aw bgf pe 041 0098 , mimic pcb for 2x30kva ac ups - aw 205 840 319-1 , dac pcb for 2x30kva ac ups - aw 205 840 320
Tender For corrigendum : electrical lab equipment - colour digital storage oscilloscope 100mhz 1gs/s with fft, voltmeter 0-500v (analog ), voltmeter 0-500v (analog ) moving iron type, ammeter 0-1-2a (analog ) moving iron type, ammeter 0-2.5-5a (analog ) pmmc type, ammeter 0-5-10a (analog) moving iron type, wattmeter lpf dynamometer type, wattmeter 5-10a, 75-300-600v upf dynamometer type, megger 500v 1000m digital insulation tester, single person push button operation, bridge trainer kit, digital earth tester, energy meter 1-phase, trivector meter, dc motor cut section for lab application with manual, transistor characteristics npn-pnp trainer kit, trainer kit for turn off circuit of scr for laboratory purpose, smps trainer kit power supply : 230 v ac , 50 hz, ups trainer kit input voltage 180-260 volts, 50 hz, three phase induction motor cut section for lab application, three phase 6 cage induction motor trainer kit ,, universal motor phase single phase, stepper motor voltage 24-48 vdc, three phase squirrel cage induction motor trainer kit for speed control using auto transformer and vvvf method mains supply : three phase, 415v 10%, 50hz, lux meter, house & commercial wiring installation trainer, speed control of dc shunt motor trainer, speed control of dc series motor trainer, functioning of ct, pt and isolation transformer complate trainer, voltmeter and ammeter method for measurement of medium resistance., clamp meter, dc, ac & wave shaping circuit trainer, oil testing kit, transformer trainer 300 va, dc motor coupled to dc motor trainer, 3 phase squirrel cage induction motor trainer, single phase ac inducation motor trainer, dc motor coupled to 3 ph ac motor trainer, 3 phase ac integrated motor coupled to dc integrated motor setup (motor-generator setup):, electrical load power factor trainer (apfc), complete house wiring installation trainer, 3 phase squirrel cage induction motor trainer, control of 3 ph. squirrel cage induction motor trainer, 3 phase slip ring induction motor trainer, 1 ph. ac induction motor trainer, 3 phase salient pole alternator coupled to dc integrated motor setup (motor-generator setup) trainer, ac servo motor trainer with pid controller, dc servo position control trainer with pid controller, measurement of linear displacement by lvdt transduser trainer, strain gauge transduser trainer, temperature sensing transduser trainer, pressure measurment by piezo resistive transducer trainer, angular speed measurement using stroboscope & tacho meter transduser trainer, op-amp trainer, adc & dac circuits trainer, pelton turbine trainer (assemble & dismantle of micro hydro plant), microcontroller trainer 8051, solar and wind turbine trainer, fuse & mcb characteristics trainer, air circuit breaker trainer (dismantle acb), induction type electromagnetic relay trainer, electromagnetic over current reley i numerical relay trainer, percentage biased differential relay trainer, motor fault simulator trainer, on transmission line protection simulation trainer., lcr meter, digital multimeter, tachometer, wire striper, pliers, ball pen hammer, earth tester, took kit, soldering iron 25 watt with lead
Tender For procurement of electrical components and minor equipment for lab - single-phase auto transformer (0-270v, 35a), three-phase voltage sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes, three-phase current sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes, three-phase autotransformer (440v, 40a), powering boards for sensors and gate driver circuits (15v, 12v, 5v), soldering iron with controllable temperature - medium (weller), gsr 120-li small rechargeable driller (bosch), lrs-600-12 dc power supply/smps mean well 12v, 50a, 600w, lrs-600-15 dc power supply/smps mean well 15v, 40a, 600w, lrs-600-24 dc power supply/smps mean well 24v, 25a, 600w, lrs-600-36 dc power supply/smps mean well 36v, 16.6a, 597.6w, lrs-600-48 dc power supply/smps mean well 48v, 12.5a, 600w, fluke multimeter 0-600v, 0-10a, rheostat 200 ohm, 20a, tektronix a622 ac/dc current probe, skkt 107/16 e- thyristor modules (1.6kv, 119a), scr module heat-sink, scr firing module, inductor filter (50a), mccb (60a), ganged potentiometer (5 ??, 3watt), digital panel mount ammeter (75a), digital panel mount ammeter (1000v), 10sq mm wire, dc shunt (75mv, 75a), lugs, hardware (base plate for scr module), single sw sic-mosfet module, sic-mosfet switches (silicon carbide mosfet, single, n, channel, 55 a, 1.2, kv, 0.075 ohm, to-247), single sw sic-mosfet gate driver, 10a igbt and sic mosfet gate drive with integrated overcurrent sensing, fault, and uvlo status feedback features acpl-, 355jc based design
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens