Get complete information related to latest Road Light Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Road Light Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Road Light Panel Tenders.
Tender For construction of succesful testing and commissioning of 0.70 lac gallons capacity oht,providing, laying and fitting of pipes, const. of rcc dome for existing sr , const. of 02 no tube wells, const. of chamber at junction, const. of panel cum operator quarter 2 nos, const. of operator quarter at oht site, repair of existing sluice chamber, const. of dg plateforms at oht site & tube well site,const. of approach path and electromechanical components for qazigund town under (amrut 2.0)
Tender For armo of e and m installations at jammu airport - highly skilled supervisor , skilled , semi skilled , un skilled , highly skilled data entry operator , 1.50 sqmm single core of 90 mtr coil , 2.50 sqmm single core of 90 mtr coil , 3 core x 1.5 sqmm of 100 mtr coil , 3 core x 2.5 sqmm of 100 mtr coil , modular plate of two module , modular plate of three module , modular plate of six module , modular plate of eight module , inner plate of two module , inner plate of three module , inner plate of six module , inner plate of eight module , two module flush metal gi boxes , three module flush metal gi boxes , 16 a one way modular switch , 10 a one way modular switch , 06 a 3 pin shuttered socket , 16 a 3 pin shuttered socket , 10 a one way bell push switch , 06 amp 3 pin plug tops , 16 amp 3 pin plug tops , 16 a one way piano type switch , 06 a one way piano type switch , 20 a two in one piano type socket , 06 a two in one piano type socket , 2.5 mfd rating capacitor , 4 mfd rating capacitor , 20 amp switch socket combined with box , 06 amp switch socket combined with box , extension cord with 04 universal socket , 10 sq mm aluminium tube terminal , 16 sq mm aluminium tube terminal , 25 sq mm aluminium tube terminal , 35 sq mm aluminium tube terminal , 50 sq mm aluminium tube terminal , 70 sq mm aluminium tube terminal , 95 sq mm aluminium tube terminal , 120 sq mm aluminium tube terminal , 150 sq mm aluminium tube terminal , 185 sq mm aluminium tube terminal , 240 sq mm aluminium tube terminal , 16 sq mm aluminium in line connector ferrule , 25 sq mm aluminium in line connector ferrule , 35 sq mm aluminium in line connector ferrule , 50 sq mm aluminium in line connector ferrule , 70 sq mm aluminium in line connector ferrule , 95 sq mm aluminium in line connector ferrule , 120 sq mm aluminium in line connector ferrule , 150 sq mm aluminium in line connector ferrule , 185 sq mm aluminium in line connector ferrule , 240 sq mm aluminium in line connector ferrule , plastic insulation self adhesive tape of 1.8 cm width and 7.5 mtr. length , 9w led lamp , 32 x 16 mm pvc white trunking , wireless call door bell including bell switch , door bell suitable to operate on 230v 50 hz ac supply , 100 watt incandescent filament bulb , 2 way gang box , 3 way gang box , 4 way gang box , supply of 4 x 16 sqmm lt cable , supply of 3.5 x 240 sqmm lt cable , supply of led aviation obstruction light , supply of 80 watt round shape led bay light suitable to operate on 230 volt 50 hz supply , supply of 250 watt led floodlight suitable to operate on 230 volt 50 hz ac , supply of insulating transformer mineral oil , 12 volt, 200ah lead acid battery , 12 volt, 180ah lead acid battery , 12 volt,150ah lead acid battery , 12 volt, 42ah smf-vrla battery , supply of acb edo type 3200 a fp fault breaking capacity 65 ka , installation testing and commissioning of new acb edo type 3200 a four pole , visiting charges for synchronizing panel by stucke or allen bradley or siemen as per site , visiting charge for any modification required in plc programming by deputing stucke or allen bradley or siemens as per site , execution of the item of work as per requirement of site from the cpwd schedule of rate
Tender For maintenance of electrical installation and fans, repair maintenance of pump set at patiala house court new delhi. (sh: providing services of wireman/operator and helper for running operation and maintenance of sub-station, diesel generator set, lt panels, pump set, fire fighting system, fire alarm and pa system installed at patiala house court.)subwork/packages:providing services of wireman/operator and helper for running operation and maintenance of sub-station diesel generator set lt panel pump set fire fighting system fire alarm and pa system installed at patiala house court.
Tender For supply of sinumerik operator panel front , encoder kit for synchronous motor ic22dq-88 drive cliq , single motor module 132a , encoder kit for synchronous motor 6fx2001-5je22-3dc1 , simodrive lt module int 2 x 25a , mini handheld unit , simatic ipc 477 15 inch , terminal module basic pn
Tender For state-of-art fully digital high end latest color doppler echo cardiology system for adult, paediatric and neonatal application with all quantification software's including contrast study, system must be offered with a minimum of 40 lakh digital processed channels. original technical data sheet should be enclosed in technical bid to support the number of channels on the systems. if not mentioned, please attach a letter from manufacturer along with the technical bid clearly stating the digital processed chan nels of the offered system, system should incorporate latest image acquisition & processing technology maintaining uniform spatial resolution, tissue uniformity through complete fov at high temporal resolution resulting high diagnostic confidence. please attach white paper on this technology, system should have broad band beam former capable of processing signals from 1-16 mhz, high resolution main display minimum size 21 inch with wide viewing angle. lnbuilt 12 inch high resolution touch screen user interface capable of image display and complete image processing & measurements, system, control panel, and monitors mounting should have continuous height and angle adjustment for operator comfort especially suitable for multiple -user depts. with high patient load., system should incorporate facility for high r~solution 2d, m mode, pw, cw doppler color flow imaging, color power angio imaging with high frame rate of min 1900fps for 2d & 200 fps for color imaging, system should have full spectrum imaging, speckle reduction filter, spatial compound imaging, phase inversion tissue hannonic imaging, trapezoidal imaging &contrast enhanced imaging(low-mi), system must be offered with speckle reduction imaging: image processing technique to remove speckles and clutter artifacts., system should have strain quantification imaging, including strain assessment for la, lv and rv, split screen view with independent cine loops & cfm. simultaneous b mode& b color mode., 2 d measurement should include calipers for distance/ depth, angle, areal circumference by ellipse/trace etc, integrated stress echo facility to perform stress echo exams., system should have real time triplex mode facility in 2d, color and doppler modes., system should have dynamic modes of 270db or higher, system should have high prf(mention rate-highest will be preferred), system should have scan depth of i to 40 cm or more. please specify through data sheet, system should have 256 shades of grey display, system should have facility for real time and frozen, pan or point zoom. cine loop as well as cine scroll facility in b mode., system should support single button to customize the workflow of doctor., system should have independent steering ofb mode and color on linear probe, system should have individual operator specific atomized workflow protocol which lets operator focus on patients, dedicated sdd of min 512gb for os for fast boot up and separate hdd for patient image storage min 1 tb, system should include anatomical mode, cardiac quantification software including auto ef, tdi, tdi quantification, and stress and strain., system should have contrast imaging with quantification for lvo study and myocardial analysis, system should include auto imt measurement and preferably based on real time data, possibility to modify/edit patient data during and after exam has been completed., system should min 8 point tgc and separately lgc dedicated cardiac applications, system should include integrated report generation sw included choice of embedded images, systems should have standard minimum 4 active probes connectors with electronic switch facility from key board. it should be provided with following transducers. a. adult single crystal phased array probe 1.5 to 4 mhz b. pediatric cardiac phased array probe 3 - 8mhz c. neonatal transthoracic transducer 4-12 mhz d. 3d tee transducer 2 - 7 mhz matrix! single crystal technology with biplane imaging and mini
Tender For custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if required., oil le