Get complete information related to latest Rolling Door Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rolling Door Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rolling Door Tenders.
Tender For supply of rs spares of kbi make - oh kit for mean pressure valve mdv1 for apl make kbi , oh kit for stopcock parking acu panel for parking and isolating cock cab pneumatic for apl make kbi , oh kit for 3by2 way cock acu panel and 3 by 2 way cock panto panel for apl make kbi , oh kit for overflow valve dr8 b01.05 acu panel for apl make kbi , oh kit for pressure reducing valve b01.06 acu panel for apl make kbi , oh kit for load limit valve dbv3 e bcu for apl make kbi , oh kit for check valve g1 a07 main air compressor for apl make kbi , oh kit for check valve rv19 t b01.04 acu panel for apl make kbi , oh kit for check valve drv7 t double b01.10 for apl make kbi , oh kit for impulse valve b01.011 acu panel for apl make kbi , oh kit for filter b01.03 acu panel for apl make kbi , oh kit for air filter u03.03 panto contol panel for apl make kbi , oh kit for anti-skid valve for apli make kbi , oh kit for valve magnet for apli make kbi , oh kit for ebmv bcu panel magnet valve panto control panel magnet valve cab for apl make kbi , oh kit for stopcock ahb200 002 b01.02 b01.07 b01.08 acu panel for apl make kbi , oh kit for levelling valve under frame for aplmake kbi , safety valve rs10 make kbi , isolating cock make kbi , magnet valve wmv1zest make kbi , swivel bearing swing trolley small size apl make kbi , support roller of saloon door apl make kbi , power module pom card for dcu door rs3 make kbi , kit for analog converter aw 4.1c for c1chk make kbi , kit for mean pressure valve mdv1 make kbi , kit for anti skid valve gv 18 2 kb make kbi , kit for bcu terminal block make kbi bid number/ & ( * ) : gem/2025/b/6046686 dated/ + : 11-03-2025 bid document/ 3 3 1 / 36
Tender For supply and installation of kitchen equipments for hostel mess at indian institute of science, bengaluru - dry store, ss platform digital weighing scale.ss platform of size 600 x 600mm, power supply - 230v ac, 50 hz, display colour/digit - red/ green/ 6 digits, display size - 0.56" (14.22 mm), number of keys - 5 keys, battery - 6v / 4ah,, mobile ingredient bin mobile ingredient bin with slant top, sliding lid, castors & scoop.37 gal. (140 l) slant top, with scoop, a hygienic clear sliding lid, bins should made of nsf-listed, fda-accepted material, bins has to be designed with a slanted top to easily access product., ss low height platform rack (dunnage rack).38 x 38mm pipe frame structure, 38 x 38mm pipe cross support with a spacing of 70mm, 6 nos leg of 38mm sq. ss legs fitted with adjustable nylon bullet feet., ss storage rack with 4 shelves.18swg ss shelves double beaded on all sides, reinforced with 25 x 100 x 25mm hat channels, dia 38mm ss round legs fitted with adjustable nylon bullet feet., walk in cooler, walk-in cooler, +2 deg c to +8 deg c.unit should be made from 60 mm thick prefab rigid puf sandwich panels with 1mm thick ss 304 grade sheet outside and inside, the cold room should be with ceiling and wall panels interlocked through a cam lock mechanism, fitted with a hermetic sealed compressor. the condensing unit should be split type, which is air cooled. swing type and insulated door having magnetic gasket, safety latch, lock and heavy duty hinges. the room should maintain a temperature of +2 c to +8 c. all accessories like light, light switch, emergency switch, door heater, vacuum release, temperature indicator to be provided with the unit. the refrigerant used should be r 134a. flooring inside the cold room is kottah stone flooring (flooring in client scope)., perforated storage rack with 4 shelves.16swg ss shelves double beaded on all sides with perforation in entire length and width, 50 x 5 mm perforation with a spacing of 15mm, stiffed with 25 x 100 x 25mm hat channels, 38mm ss round legs fitted with adjustable nylon bullet feet., veg prep area, ss work table with 2 sink unit & 1 u/s.16swg ss sunken top double beaded on all sides, reinforced with 25x25mm ss pipe frame structure, 2 nos sink of size 450 x 450 x 300mm deep, radius corners, fitted with 38mm waste coupling, 150mm splash guard on rear and (left/right) sides, 18swg ss under shelf reinforced with ss channel with 150mm clear gap from ffl, properly soundeadned, 38x38mm sq ss legs fitted with adjustable nylon bullet feet., mixer faucet, single hole, deck mount mixing faucet.single hole deck mount mixing faucet with polished chrome plated brass body, 10 1/8" swing nozzle with full flow laminar flow device, quarter-turn ceramic cartridges, lever handles, 18" flexible stainless steel supply hoses with 1/2" npsm / 5/8" o.d. compression connections. certified to asme a112.18.1\csa b125.1, nsf 61-section 9 and nsf 372. meets ada ansi\icc a117.1 requirements., single hole single temperature deck mount faucet for ro watersingle hole single temperature deck mount faucet with polished chrome plated brass body, 5 7/8" swivel gooseneck, 2.2 gpm aerator, ceramic cartridge, lever handle and 1/2" npsm male inlet. certified to asme a112.18.1\csa b125.1, nsf 61-section 9 and nsf 372. meets ada ansi\icc a117.1 requirements., chopping table with 1 u/s.full length and full width 40mm food grade nylon chopping board supported by ss angle frame, 150mm rear splash on rear side, 18swg ss under shelf reinforced with ss channel with 150mm clear gap from ffl, properly soundeadned, 38x38mm sq ss legs fitted with adjustable nylon bullet feet., ss work table with 2 u/s.16swg ss top double beaded on all sides, reinforced with 25x25mm ss pipe frame structure, 150mm splash guard on rear side, 18swg ss under shelf reinforced with ss channel with 150mm clear gap from ffl, properly soundeadned, 38x38mm sq ss legs fitted with adjustable nylon bullet feet., commercial knife sterilize
Tender For supply of set of pivot assembly for double side swing door to drg.no. icf/sk3-5-6-018 col.i&ii,alt 'nil ( item no. 01 to 06) [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of foot valves for water works purpose as per is 4038 (latest) (q3) , swing check type reflux valves for water works purposes (single door pattern) (v2) as per is 5312 (part1) (q3) , sluice valve for water works purposes (50 to 1200 mm size) (v2) as per is 14846 (q3) , copper alloy gate valve for waterworks purpose as per is 778 (q3)
Tender For supply of glass for swing door for entrance to ac area as per attached specification [ warranty perio d: 30 months after the date of delivery ]
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of sitc of pressure monitoring system , pressure relief dampers , medical gas pipeline , laminar air flow , ahu and other accessories. , copper pipe for ahu , vrf outdoor unit , ahu vfd with control panel , ducting , insulation , volume control damper , fire control damper fusible link , ra grill , clean room luminaries , recessed round down light , mirror light , electric switch and socket complete set six module , electric switch and socket complete set three module , electric switch and socket complete set four module , electric switch and socket complete set two module , four square mm copper wire with conduit , twenty five mm ms conduit along with accessories , aluminium armoured cableone hundred twenty sq mm along with cable tray , two and half copper flexible cable three core , ten sq mm copper armoured cable four core along with cable tray , copper armoured cable six sq mm along with cable tray , mccb panel , electrical panel with all accessories , electrical db with all accessories , wall panel system puff , ceiling panel system puff , ups , pvc flooring with self levelling antistatic , dismantling aluminium partion door glazing etc , h type stainless steel handle , tower bolt , brick work , cement plaster , cement based putty , wall painting , hermetically seald siliding door , aluminium work for fixed partition , aluminium work for window and door , glazing in aluminium door window ventilator etc , door closer , reinforced cement concrete work , centering and shuttering including strutting propping etc , steel reinforcement for rcc , mortice latch and lock , vitrified tiles in different sizes , dgu fixing in window , demolishing brick work , painting with synthetic enamel paint , removing dry or oil bound distemper water proofing cement paint , removal and refixing mineral fibre false ceiling tiles , steel work in built up tubular , pre painted galvatume aluminum zinc coating gi based corrugated steel sheet , hermetically seald swing door , sitc of hermetically seald swing door , corner coving