Web Analytics Made Easy - StatCounter

Rotavapor Tenders

Get complete information related to latest Rotavapor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rotavapor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rotavapor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :38601283 Due date: 27 Dec, 202427 Dec, 2024 NA
Tender For supply of led red flasher tail lamp , led yellow flasher tail lamp , dc round cables pvc insulated size of conductor 8sq mm core 1 , dc round cable pvc insulated size of conductor 1sq mm , dc round cable pvc insulated size of conductor 1 point 5sq mm core 10 core , dc round cable pvc insulated size of conductor 2 point 5sq mm core 2 core , working led assembly hella r 1500 15 watts to 18 watts , dome type head light 24 volt with 3 pin , led cabin light rmv wattage 5w siz 20 cm x 10 cm , toggle switch rating 10 a and 24 v sl double pole contact , red panel led indication lamp for rmv size 22 point 5 mm power 0 point 5w volt 24v ac by dc type esbee e series make kaycee or equivalent , green panel led indication lamp for rmv size 22 point 5 mm , yellow panel led indication lamp , red push button 30 mm 24v dc , green push button , no contact element iec , nc contact element iec , battery knife switch

Central Government / Public Sector

CTN :38604488 Due date: 31 Dec, 202431 Dec, 2024 NA
Tender For supply of design and manufacturing of test bench for master controller (both bhel & cg make and stmc) of demu/dhmu/tower car in molded sheet metal with powder coating admeasuring 6 feet x 2 feet x 2 feet (top and bottom compartment) and 6 feet x 2 feet x 1 feet (mi ddle compartment) with mounting for both model master controller. 1)dc led indication panel=20nos. 2) digital dc voltmeter 0-200 v dc =01no. 3) rotary switch 3 way position 20a =02nos. 4) mcb 16a dc double pole = 01 no. 5) wiring with copper e-beam 4sq.mm cabl e (10 mts red and 10 mts black) = 50mtrs. [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :38583166 Due date: 30 Dec, 202430 Dec, 2024 NA
Tender For supply of [ led indication lamps of rating 110v dc, set consists of red, green, orange, white- 01 no. each with diameter of 22.5mm in size suitable to alind make c&r panel of makes binay or vaishno or vinex or teknik or siemens.]

State Government

CTN :38520922 Due date: 19 Dec, 202419 Dec, 2024 NA
Tender For replacement of various items at various 220kv and 132kv substations under etd budaun - a) replacement of old & defective/damaged equipments 132kv & 33kv control panel, relay panel, transfer bus coupler panel/dcdb/110volt ac charger/33kv vcb at various substations under etd, budaun. 1) dismantalling of old/obselete/damaged 132kv control panel/relay panel/transfer bus coupler panel/33kv triple feeder panel/dcdb/110volt ac charger/33kv vcb by opening of all associated control cable and earthing and shifting of above from control room to store., 2) erection of new 132kv control panel/relay panel/transfer bus coupler panel/33kv triple feeder panel/dcdb/110volt ac charger/33kv vcb alongwith foundation modification if required with earthing and cable termination and shifting of above from store to site and other associated works., b ) overhauling of 33kv vcb (mechanical/electrical) 1) mechanical overhauling of 33kv vcb that includes checking of opening mechanism, closing mechanism, spring charge mechanism, changing of pole assembly or vaccum interrupter etc. (01 job per breaker)., 2) electrical overhauling of 33kv vcb that includes checking of tripping circuit, closing circuit, indication, trip cicruit supervision etc. (01 job per breaker)., c ) replacement of old rusted 132kv pt/ct junction box including removal of old junction box after opening all cable termination and installation of new junction box alongwith cable termination and cable laying work (if applicable) (01 job/01juction box), d) replacement of old rusted 33kv pt/ct junction box including removal of old junction box after opening all cable termination and installation of new junction box alongwith cable termination and cable laying work (if applicable) (01 job/01juction box)

Central Government/Public Sector

CTN :38157116 Due date: 27 Dec, 202427 Dec, 2024 1.30 Crore
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous

Central Government/Public Sector

CTN :38041097 Due date: 21 Dec, 202421 Dec, 2024 NA
Tender For corrigendum : custom bid for services - repair and maintenance of ac modules dc modules and various pcbs of all departmental drilling rigs of ongc tripura asset-work includes but not limited to supply of men, materials, testing equipment / tools etc for fault finding (trouble shooting), repairing, calibration and functional testing of ac modules, dc modules and various pcbs in e1400 series drilling rigs of tripura asset. broad details of the activities to be carried out are as below: a. following jobs are to be carried out in pcbs i. physical checking of healthiness of components & cleaning of the pcbs. ii. checking of voltages at different points in the pcbs after powered up through simulator. iii. replacement of faulty components, limited to 50% cost of the pcb, to make it operational. iv. calibration of pcbs v. on load testing of 12 hrs. continuous loading for satisfactory operational vi. fixing of pcbs in the respective panels b. following jobs are to be carried out in ac module i. visual inspection of module for any loose hardware & cleaning of the module. ii. checking of circuit by using simulator. iii. checking of over frequency tripping. iv. checking of under frequency level. v. under frequency voltage cut back test vi. idle-run ramp and idle trip test vii. throttle regulation check viii. master slave and command circuits check ix. current demodulator check x. automatic voltage regulator check xi. meter circuit check xii. over voltage trip check xiii. reverse power trip check xiv. frequency demodulator check xv. module panel meter check xvi. replacement of faulty components, limited to 50% cost of the ac module, to make it operational. xvii. on load testing of 12 hrs. continuous loading for satisfactory operational xviii. fixing of ac modules in the generator panel c. following jobs are to be carried out in dc-module i. visual inspection of module for any loose hardware & cleaning of the module. ii. dead band and current limit calibrations iii. zero throttle interlock circuit test iv. firing circuit test v. speed feedback circuit test vi. power limit circuit test vii. slave circuit test viii. manual voltage circuit test ix. over current trip calibration test x. meter circuit check xi. replacement of faulty components, limited to 50% cost of the dc module, to make it operational. xii. on load testing of 12 hrs. continuous loading for satisfactory operational xiii. fixing of dc modules in the dcpcr panel d. following jobs are to be carried out in battery charger i. visual inspection and cleaning of components such as transformer, voltmeter, ammeter, pcbs, rectifier, indication lamps and tightening of loose hardware, if any. ii. checking of tripping logics, dc under voltage, dc over voltage, reverse polarity, ac mains fail, over current, over temperature etc. iii. replacement of faulty components, limited to 50% cost of the battery charger, to make it operational.-msme exemption - no | startup exemption - no

Central Government And Public Sector

CTN :38057097 Due date: 26 Dec, 202426 Dec, 2024 37.25 Lacs
Tender For corrigendum : supply of installation of damaged spare parts of plc and scada system - control transformer 1kva , motor protection cuircuit breaker, range- 51 -70a , breaker handle with knob, siemens 3vt series , panel door lock for power pack , ethrnet switch 5-port unmanaged, ports- 5 unmanged type aux. supply- 24vdc , smps din rail mounted 24v dc 10a, output- 24v dc, 10a din rail mounted type , star delta timer, 0 -60 sec , panel fan, 220v ac, size 6 inch , mcb 2.0 amp. single pole , mcb 4 a single pole , single pole mcb 6 amp , mcb 4 a double pole , dc mcb double pole 220 v dc 06 amp , tripple pole mcb 4a, c04 , mcb tripple pole, c curve, 6amp , relay 8-pin with base, 8-pin 24v dc with base , space heater, rating-500w 230v ac , pressure gauge, analog type, range- 0-500kgf per sq. cm , tank oil gauge, tank mounted direct measuring , directional solenoid valve, operating pressure- 315 kgf per sq. cm coil voltage-24v dc , gate position sensor for radial gate, e1-type range 0- 360 degree, analog output 4 - 20 ma , indication light - blue, indication lamp 22.5 mm 220v ac blue , differential pressure transmitter, two wire 4 -20 ma dc output with hart , level transmitter accuracy 5-10 mm , gate position indicator 5 digit 0.56 inch display 21 , voltmeter 0- 500v - analog , push button red with nc add on , ammeter, 0 -250a analog , indication light - red, indication lamp 22.5mm 220vac red , indication light - yellow, indication lamp 22.5mm 220v ac yellow , indication light - green, indication lamp 22.5mm 220v ac green , jumbo display size 6.5 inch usb ports 2.0 x 1, 3.0 x 1 , push button yellow with no add on, size 22.5 mm , push button blue with no add on, size 22.5 mm , push button green with no add on, size 22.5 mm , push button black with no add on, size 22.5 mm , emergency push button, size 22.5 mm , phase preventer relay system ac mode auto , utp cable cat-5e , cable 1.5 sqmm 4c flexible 100m bundle , 1024 tags and ddls of scada system , control terminal block, 2.5sq.mm , service engineer charges , traveling charges , freight charges

CTN :38471489 Due date: 27 Dec, 202427 Dec, 2024 NA
Tender For supply of set display (item no 11063182) in the existing rotavapor r- 300.

Central Government/Public Sector

CTN :38466473 Due date: 06 Jan, 202506 Jan, 2025 NA
Tender For supply of interior stickers with braille script for lhb scn coaches., as per drawing: ls 64007 alt b item no.1,2,6,8,13 to 17,19,21,23,25 & 26 with braille script as per mcf's specifi cation no. mmdts-22001 rev. nil or latest, packing instruction: pi136 ver 2.0, lettering inside : one complete set of lettering inside should be packed in cardboard box. different sub sets should be made & a list of items should be pasted on each packet of subsets. lette rs packed in each subset under different headings are as under:- plumbing : emergency flush button, press for flush, notice for bio toilet moulding:- duties of coach attenda nt, push, pull, no smoking, alarm and penalty notice, door closes automatically, safety message near gate, notice for luggage capacity. lavatory:- dust bin, fire extinguisher, soap dispenser, no drinking water, no waste into toilet, western style, press for flush , fire prevention and safety, marking of lavatories / body side door, notice for lavatories, drinking water, unified notice for fire prevention & safety. seat & berth:- st icker for seat number, berth numbers, letter for chaining luggage, notice for unreser ved coaches. air brake:- reset emergency brake, feed pipe, brake pipe, closed, open, hand brake panel : furnish plate, complaint book. window & ceiling: pull window glass inside, indication plate & sticker for emergency window, emergency openable window. note : fi rms have option to provide qr code the cardboard box shall carry a qr code having de tails as listed below : " name of the manufacturer " purchase order numb er " purchase order date " unique serial number (or lot number for bu lk items) of the manufacturer or " date of manufacture " delivery challan no. " delivery challan date the qr code shall be as per iso/iec18004 model2 and the data shall be available as xml using t he tags detailed above. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :38466474 Due date: 06 Jan, 202506 Jan, 2025 NA
Tender For supply of interior stickers with braille script for lhb ac 3 tier coaches., as per drawin g: le64016 alt b item no 1 to 7, 9 to 11,13, 15, 18 to 22,27 & 29 with braille script as per mc f's specification no. mmdts-22001 rev. nil or latest, packing instruction:pi136 ver-2.0, letteri ng inside: one complete set of lettering inside should be packed in cardboard box. diffe rent subsets should be made & a list of items should be pasted on each packet of subse ts. letters packed in each subset under different headings are as under:- plumbing : em ergency flush button, press for flush, notice for bio toilet moulding:- duties of coach attendant, push, pull, no smoking, alarm and penalty notice, door closes automatically, safety message near gate, notice for luggage capacity. lavatory:- dust bin, fire extinguisher, soap dispenser, no drinking water, no waste into toilet, western style, press for flush, fire prevention and safety, marking of lavatories / body side do or, notice for lavatories, drinking water, unified notice for fire prevention & safety. s eat & berth:- sticker for seat number, berth numbers, letter for chaining luggage, noti ce for unreserved coaches. air brake:- reset emergency brake, feed pipe, brake pipe, clo sed, open, hand brake panel : furnish plate, complaint book. window & ceiling: pull wind ow glass inside, indication plate & sticker for emergency window, emergency openable window. note : firms have option to provide qr code the cardboard box shall carry a q r code having details as listed below : " name of the manufacturer " purc hase order number " purchase order date " unique serial number (or l ot number for bulk items) of the manufacturer or " date of ma nufacture " delivery challan no. " delivery challan date the qr code shall be as per iso/iec18004 model2 and the data shall be availa ble as xml using the tags detailed above. [ warranty period: 30 months after the date of deli very ]
 Loading, Please wait...

Connect us via What's Up