Get complete information related to latest Rough Balance Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rough Balance Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rough Balance Tenders.
Tender For corrigendum : supply of ss sheet sus 301l-dlt - dull finish of size 2 mm x 1250/1500 mm x 2150 mm to jis g 4305 standard. special condition : i) the sheets/plates shall be supplied in bundles with double layer of water proof paper & a bio degradeable plastic sheet of suitable thickness and metal protection in edges. all the sheets up to 2mm thickness shall be protected against corrosion and rust by coating corrosion preventive fluid, soft film, solvent deposited, water displacing to is: 1154. ii)all bundles shall have a minimum of 2 hoopsup to 1.2 meter in length and one extra hoop for every additional meter. the bundles shall also be provided with skid (wooden packing under neath) to facilitate handling.iii) optimum weight of the bundle should be 2mt+-10%. mechanical damange & corrosionduring transit if any shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of ss sheet sus 301l-dlt - dull finish of size 2 mm x 1250/1500 mm x 2150 mm to jis g 4305 standard. special condition : i) the sheets/plates shall be supplied in bundles with double layer of water proof paper & a bio degradeable plastic sheet of suitable thickness and metal protection in edges. all the sheets up to 2mm thickness shall be protected against corrosion and rust by coating corrosion preventive fluid, soft film, solvent deposited, water displacing to is: 1154. ii)all bundles shall have a minimum of 2 hoopsup to 1.2 meter in length and one extra hoop for every additional meter. the bundles shall also be provided with skid (wooden packing under neath) to facilitate handling.iii) optimum weight of the bundle should be 2mt+-10%. mechanical damange & corrosionduring transit if any shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For auction sale of pway scrap - scrap p-way material such as 1] rail 90r, 346.560 rms = 15.46 mt, location: km-98/36-99/04, 2] scrap rail 52 kg, 176.810 rms = 9.175 mt, location: km-98/36-99/04, total qty. in weight = 24.635 mt, custodian: sse pw nwu , mode of delivery by running meter , but will be sold as standard weight in mt, loading by purchaser, note: 1] purchasers are requested to see lot/site personally before bidding , no claims will be entertained from bidder side in later stage/after sale , 2] delivery dates will be fixed through ireps. purchasers are advised to submit online request through ireps system atleast 07 days before for fixation of delivery dates after prepration of delivery order, 3] fdp 50 days
Tender For supply of refrigerant gas r-407c confirming to is: 5610/1993, re affirmed-2006 or latest if any, in 45 kgs capacity standard cylinders on non returnable basis by filling refrigerant gas r-407c. note: gas must be filled in company's sealed refrigerant gas cylinders indicating cylinder weight, net weight of the gas & gross weight, date of refrigerant gas along with test certificate of gas & cylinder, otherwise subject material is liable for rejection. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of i year physics, chemistry lab items dept use - digital balanceweight 500g, accuracy 0.01g, top pan. tare function,caliberation- automatic external display type: led, digital tds meter range 0-9990 ppm, resolution 1ppm, digital lcd display, atc feature., heating mantlecapacity: 500ml rating 200w with energy regulator, joule calorimetercopper vessel, battery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), thermometer (alcohol), stop clock, hotplateplate size:25 x 30 cm (10 x 12 inch) with adjustable thermostate controlup to 350 degree temprature controlheating element: nichrome heating elementpower supply: 220 240 v ac, 50 hz, electric bunsen burnermaximum temperature up to 800 degree c, power supply 220 to 240 v, power 350 w, water distillation unitoutput capacity: 2 4 liters per hourmaterial: stainless steel boiler and condenserheater: built-in electric heating elementpower supply: 220 240 v ac, 50 hzcooling: water-cooled condensersafety: automatic low water cut-off, ohms law verification kitbattery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), standard resistance coil of 1, 2 ohm (2-set) wound on a wooden bobbin, boyles law apparatusthe apparatus includes the quill tube, a retort stand, a clamp, and a mounted meter scale.quill tube specifications:length: approximately 50 cm.bore diameter: uniform bore, roughly 1 mm to 2 mm.construction: glass tube with one end sealed.trapped substance: a mercury pellet (or thread) of length 10 to 15 cm is introduced to enclose a column of air. mounting: attached to a half-meter or meter scale., helical spring apparatusstructure: a rigid support mounted on a heavy metal base, typically cast iron, to ensure stability during tests.springs: high-tensile steel spiral springs, typically (approx 25 mm) diameter, (100 mm) long.measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement. loading mechanism: a, typically (50g), hook-attached weight hanger at the bottom. pointer: a fine pointer attached to the bottom of the spring moves along the scale.accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For corrigendum : d. supply of milk testing glassware and chemicals. 70 sets - d) milk testing glassware & chemicals, milk butyrometer (isi make), double tested, for milk 0-10%, accuracy 100%, lactometer zeal type ,0 to 40 with division, calibrated at 84 f as per mother dairy standard, accuracy+_0.25 lr, thermometer(alcohol), 0 to 1000 c, yellow back, accuracy 100%, graduated pipettes 10 ml ( original borosil), milk pipette 10.75 ml , double tested, test tubes 18 x 150 mm ( original borosil, glass beakers , 100 ml ( original borosil ), glass beakers, 500 ml ( original borosil ), porcline dish , 3 inch, sprit lamp, stainless steel , 100 ml., plastic sample bottles , 50 ml, with cap, made from food grade plastic (as per approved sample),minimum weight-5.5 gm, plastic tray for holding 24 nos. sample bottles securely , made from food grade plastic, minimum weight 300 gm +_10 gm, tray for reagents, size 16x12 inches, made from food grade plastic, plastic tilt measure 1ml for alcohol with rubber cork & with plastic bottle of 250 ml., plastic tilt measure 10 ml for acid with rubber cork & with plastic bottle of 500 ml, test tube stand for 12 tubes of size18x150mm , made from aluminum, nylon brush for cleaning pipettes, nylon length 4 inches, total length 12 inches, nylon brush for cleaning 50 ml milk sample bottles, nylon length 4 ",with tail & thick steel wire, heater, acid (20 kg.) & alcohol (2 ltr)
Tender For rate contract for 02 years( extendable) for purchase of various types of consumables for department of aneaesthesiology, pgims, rohtak- heat & moisture exchange filters (hmef): hepa bacterial and viral fi with hme properties offering optimum hydrophobic filtration performance. gas sampl port, for end tidal co2 monitoring. recommended tidal volume range 150-1200ml.ev pleated filter medium to allow maximum filtration efficiency with minimal resistance flow. low dead space, not more than 45-55 ml. single use, sterile ece/usfda/iso/ , heat&moisture exchangers (hme) filter for pediatric us , recommended tidal volume <600ml.low weight. low dead space. suitable for b ventilated and spontaneously breathing patients. low resistance to flow. corrugated pa medium with high efficiency to recover about 75% of the energy and moisture. single sterile. ece/usfda/iso , heat & moisture exchangers (hme) for spontaneous breathing in tracheostomized patients. suction port to allows access to suct , catheter. clear housing to allow visualization of contamination. integrated oxygen port allow delivery of supplemental oxygen. recommended tidal volume range from 1000ml.compact and lightweight. corrugated paper medium device can be used fo maximum period of 24 hours. single use sterile. minimum resistance anti occlus mechanism. ece/usfda/iso , epidural set. a set containing tuohy's epidural needle minimum length 80m 16g, 17g and 18g, and corresponding gauge epidural catheter with closed tip and th lateral eye, length 90-100 cm and flat filters 0.2 micrometer hydrophilic two way, fill area approx 4.91 cm², priming volume 0.75 ml all connections should be of luer lock ty lor(loss of resistance) syringe, presterilized. ece marked/usfda approved , combined spinal epidural set. containing 18 g touhy epidural needle minimum 80 mm length. pencil point, spinal needle with twist lock system, marking tuohy's needle hub and depth marking on tuohy's needle hub containing correspond clear catheter with connection, closed end and 3 lateral eye of approx. length 90-100 with epidural filter 0.2 micrometer hydrophilic two way, epidural sponge and lor (loss resistance) syringe. ece marked/usfda approved - , needle for spinal anaesthesia, quincke type, same colour coding the hub and stylet, presterilized. usfda and europen ce approved- , (a) 23 g, 90mm length od approx 0.64 mm, , (b) 24g,90mm length od approx 0.5mm with/without introducer , (c) 25g, 90 mm , (d) 26g, 90 mm , (e) 27g, 90mm , paed. spinal needle without introducer, colour coded length 50mm, g, od 0.5 mm, presterilized. usfda and europen ce approved , cuff manometer: allows controlled initial cuff inflation. intermittent press monitoring facility. instant visual confirmation of intra-cuff pressure. simple operation pressure adjustment without need for disconnection or introduction of syringe into syst solid green zone indicates usual cuff pressure range for tracheal & tracheosto tubes.connecting tube is supplied with the gauge for convenient positioning. portable ga and clips easily into pocket. , face mask- clear, reusable, pvc material, transparent for good visibil adjustable cushion for better comfort. , sizes:- , a) 0, , b) 1, , c) 2, , d) 3,0) 4,1) 5- , anatomical facemask made up of antistatic inflating pad, malleable, anatom. chaned to give precise seal and fit comfortably, sizes 1.2.3.4 , disposable lma with preformed curve 90 degree like ilma with airwa tube with standard connectors for anaesthesia circuit. us fda approved. sizes 1, 1.5,2, 2.5,3,4,5 , resuable pressure infusion bag for administration of fluid to patient unde pressure, compatible with 500 ml fluid bags, flexible, stury, pvc tubing and manometer stop cock and hand pump, latex free , clear pressure- monitoring lines, which can withstand pressure up to 500 psi with minimal damping, non kinkable, pre-sterilized, disposable, id/ed1/2 mm. length 100 cm, 150cm & 200 cm. low dead space but pe may be optional. , 17ofessor