Web Analytics Made Easy - StatCounter

Route Indicator Repair Tenders

Get complete information related to latest Route Indicator Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Route Indicator Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Route Indicator Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :44454846 Due date: 28 Mar, 202628 Mar, 2026 NA
Tender For supply of precast slab size 1000x500x100mm , precast slab size 1200x500x100mm , precast slab size 1500x500x100mm , precast slab size 1000x300x100mm , precast slab size 1800x300x100mm , ready mix bitumen concrete 25 kg bags , spring post , spring post round , barricades , safety cones , hazard marker , cement opc43 grade , ehd35 manhole cover , hd20 manhole cover , grating with frame

State Government

CTN :44467630 Due date: 25 Mar, 202625 Mar, 2026 NA
Tender For supply of precast concrete manhole cover and frame (v3) conforming to is 12592 (q3)

State Government

CTN :44467693 Due date: 24 Mar, 202624 Mar, 2026 NA
Tender For supply of precast concrete manhole cover and frame (v3) conforming to is 12592 (q3)

Corporations And Associations And Others

CTN :44434431 Due date: 18 Mar, 202618 Mar, 2026 4.95 Lacs
Tender For supply of coarse sand, precast rcc cover and frame horizontal grating and precast rcc manhole cover and frame in ward no. 79/cspz. ballimaran.

CTN :44438677 Due date: 23 Mar, 202623 Mar, 2026 NA
Tender For providing r.c.c precast chamber cover at various area of vapi municipal corporation area (annual rate 2026-2027)

corporations/Associations/Others

CTN :44416942 Due date: 25 Mar, 202625 Mar, 2026 NA
Tender For procurement of r.c.c. precast frame and cover for storm-drainage inlet chamber (6-month rate contact) (3rd attempt)

corporations/Associations/Others

CTN :44423378 Due date: 18 Mar, 202618 Mar, 2026 NA
Tender For work of purchasing rcc precast cover for inlet chamber of storm-drainage line in surat municipal corporation.

CTN :44430638 Due date: 23 Mar, 202623 Mar, 2026 NA
Tender For supply of precast concrete manhole cover and frame (v3) conforming to is 12592 (q3)

CTN :44404092 Due date: 21 Mar, 202621 Mar, 2026 NA
Tender For supply of enamel, synthetic, exterior (a) undercoating (b) finishing (v4) confirming to is 2932 (q3) , barbed wire , mild steel flat iron 40 by 4 thick , tmt bar 10mm dia , nut and bolt 10mm and 50mm , precast rcc drain or machine cover 900x450x50mm thick , precast rcc drain or machine cover 450 by 450 by 50mm thick , precast rcc drain or machine cover 600 by 450 by 50mm thick , precast rcc drain or machine cover 450mm dia by 50mm thick , angel iron 50 by 5 by 06mm , 20mm stone aggregate , primer for steel surface , mild steel binding wire 0. 9 mm dia , mild steel ms grating heavy duty 900 by 450mm , mild steel ms grating light duty 900 by 450mm

Central Government/Public Sector

CTN :43698963 Due date: 17 Mar, 202617 Mar, 2026 2.99 Crore
Tender For corrigendum : provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, brea
 Loading, Please wait...

Connect us via What's Up