Tender For corrigendum : supply of visual inspection and photography performing a visual survey of the building and recording/maping on drawing to assess extent of spelled concrete, cracked concrete, honey combing, reinfocement corrosion, delaminated concrete etc, taking photographs and videos to collect evidence of damage to structure., ultrasonic pulse velocity test for rcc structure in accordance with is 13311 part-i 1992 by portable ultrasonic non destructive digital test equipment including chipping out plaster at strategic locations., rebound hammer test: rebound hammer test in accordance with is 13311 part-2 1992 by portable rebound hammer equipment at strategic locations., core test: core cutting and compression test for rcc structure in accordance with is:516 on rcc members. 70 mm core cutting in reinforcement concrete, core filling by speialized epoxy material/micro concrete with bond coat at strategic locations., reinforcement mapping :- reinforcement mapping test on rcc members to assess covers, spacing of bars including approximate diameter at strategic locations., chemical test for rcc structure in accordance with is 456-2000 using ready made kits and, reagents. sample collected will be from half cell/carbonation powder. (i) determination of ph value. (ii) determination of water soluble sulphates. (iii) determination of water soluble chloride contents at strategic locations., half cell potential test for rcc structure in accordance with astm c876 half cell potential to assess the probability of corrosion of reinforcement at strategic locations., carbonation test for rcc structure in accordance with bs 1881-201-1986 claus 2.22 corbonation test to measure extent of carbonation from the concrete surface at strategic locations., providing & installing standard precision tell- tales for crack monitoring & recording., providing installation 2mm thick glass strip for crack monitoring & recording., carry out excavator at 3 locations to verify size of footing on site., to assess the existing soil at founding depth by taking soil samples and carrying out shear strength test, index properties test, consistency limits & obtain sbc at founding depth geo-tech consultant., to assess the structural condition crack patterns and submit structural inspection report with remedial measures, to provide vetting report from iit mumbai with detailed calculation and drawing further submission to ce office.
Tender For supply of procurement of precast reinforced concrete bench rcc bench as per requirement : : -1 providing and fixing of 3 seater rcc bench made of 75 mm thick 1 , 2 providing and fixing of 3 seater rcc bench made of 75 mm thick 1 , 3 fixing of 3 seater rcc bench made of 75 mm thick rcc slab 2 , 4 providing of 3 seater rcc bench made of 75 mm thick rcc slab finished by different number3 , 5 providing and fixing of 3 seater rcc bench made of 75 mm thick rcc slab finished by different number fambry stone and two coats of 124 no sealer coat to prevent from weather4
Tender For ?????? ??????? ?? ???????? ? ?????. ?????? ?? ?????? ??????? ??????? ?? ??? ????????? ????? ?? ????? ????? ?????? ??????? ??????? - installation of rcc (reinforced cement concrete) benches at bus stands and public places within the panchayat area undertaken by gram panchayat bandhanau dikhanada.
Tender For structure two storied rcc framed structure with solated,combined ,raft footing ,as per structural design obtained from pwd design wing column, plinth beam, slab, stair case etc. using m30 design mix concrete nominal mix using graded broken stone
Tender For corrigendum : special repair to reinforced cement concrete (rcc) overhead tank near building no. p-6, provn of overhead shed and interlocking tiles in front of building no. p-58 at sangrur under ge (south) patiala
Tender For 82645/e8 provn of station gym at af stn thanjavur - general summary (note : schedule a part i building/ structure is not pre priced by mes and the pre priced rate indicated as "rs. 0.00" under col.5 signifies this fact only. bidder shall insert their rate in green field under column 6), schedule a part i building/structures design and construction of rcc m-25 framed structure (single storey) with permanent specifications in rcc m-25 with brick masonry panel walls, att, pu based wpt, earthquake resistance as per latest is etc incl rcc foundation etc complete all as specified and as shown in architectural drawing / approved structural drawing.note:- the contractor shall submit structural design & drawing of the building under sch a part i (prepared based on architectural drawing forming part of tender document) duly vetted by any iit / nit or any govt engineering college within the time limit shown in schedule a notes., general summary (note : schedule a part ii to v are prepriced by mes under ser no. 04 to 07. bidders shall insert their lumpsum amount in the green coloured field under col-6 only), total of schedule a part ii internal electrification , total of schedule a part iii internal water supply", total of schedule a part iv road / hard standing", total of schedule a part v sewage disposal , sch a part- vi - miscellaneous items (note : this schedule is not pre priced by mes and the pre priced rate indicated as "rs. 0.00" under col.5 signifies this fact only. bidder shall insert their rate in green field under column 6), m&l for on site lldpe septic tank for 25 users capacity designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation,vent shaft, connection etc., complete all as specified and as directed., m&l for soakage well 2.4m dia x 4.5 m effective depth with cover in any type of soil , foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonry in cememt mortar, rcc cover slab in m25 cover, interconnecting pipes of rcc/dwc complete filled with brick bats complete all as per ce af bangalore td drg no afb/td125 sheet no 1/2 and 2/2 and ce a&n zone drg no ce/td/2022/16 steet 1/1., s&f turbo force wall mounted fans complete with blades and accessories, 230 v, 450 mm sweep five star rated including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by engineer-in-charge.
Tender For auction sale of others - scrap - abandoned structure (1) location - abandoned qtrs. no. 160 type - ii , 10 units , 161 type - ii , 10 units 581 type -ii ,02 units , 583 type- ii, 02 units , 487 type - ii ,02 units ,165 type- ii, 02 units,1030 type-i,04 units, total =type i=04 units, and type -ii = 28 units in gaya colony, description of materials - released bricks ,released bricks bates , released rail & iron ,scrap wood, released concrete (rcc), released a.c sheet , released raniganj patteren tiles, lot no- ssew/1/19/ddu released bricks/2026.