Tender For supply of supply and laying of 4c 50 sqmm copper armoured power cable from transformer to powerhouse at dnlh d d - supplying of the 4core x 50sqmm one length copper armored pvc insulated pvc sheathed xlpe power cable from transformer to power house , supplying of the 200a 3 pole 25 ka molded case circuit breakers mccb , laying and fixing pvc insulated and pvc sheathed xlpe power cable of 1. 1 kv grade on wall surface as required , supplying and making end termination with brass compression gland of cable , supplying and filling in plinth with sand under floors including watering ramming consolidating and dressing complete with all labour materials transport in hilly area , laying one number pvc insulated and pvc sheathed xlpe copper armoured 1. 1 kv cable in existing cement trench removing sand cushioning placing new cable properly with all labour tools , installation of 200a 3 pole mccb on existing db including dismantling old mccb making connections with suitable lugs and cables tightening terminals testing and commissioning as required. , supplying and fixing 400 400 15 mm seasoned wooden board for mounting 200a porcelain kit kat fuse at the powerhouse including cutting drilling anchor fasteners holes. , supplying and installing 200a porcelain kitkat fuse on pre fixed wooden board, including incoming outgoing cable connections with copper lugs , supplying and fixing 200a neutral link suitable for terminating multiple neutral cables in lt distribution system mounted on pre fixed wooden board , removing outer sheath of 4c 50 sqmm copper armoured xlpe cable up to 2 m and terminating each core at energy meter using heat shrink sleeves including supply laying , providing laying and fixing 75 mm dia medium class gi pipe in rcc road with gi fittings including 75 mm trenching refilling with rcc materials and using all necessary machinery tools etc. , cable jointing of existing 4c 50 sqmm xlpe copper armoured cable using approved heat shrink kit including stripping cleaning crimping with copper lugs heat-shrink sleeves sealing insulation materials , supplying and fixing 6 mm multiwall polycarbonate sheet as shed roofing over energy meter enclosure 1 m length plus 1 m projection with gi supports cutting fixing with screws edge channels , making 4 inch hole in lighthouse entrance gate wall 600 mm thick for cable entry using necessary heavy machinery and tools and refilling as required , add extra charges for executing electrical work at dolphin nose lighthouse in hill area considering difficult terrain limited access higher labor effort and transportation challenges , miscellaneous items including ss screws anchor fasteners nuts and bolts as required gi clamps for cable fixing copper lugs and other necessary materials.
Tender For corrigendum : supply, installation and commissioning of spect dual head gamma camera system for nuclear medicine department of mnjio and rcc with accessories, ( latest model of dual head gamma camera with variable angle facility, spect imaging and whole body imaging capability with high resolution and optimal count sensitivity. )qa , dosimetry items , high dose radioiodine ward with delay tanks , ups with batteries , hvac system/ air conditioning works , electrical works , local items , turnkey and other works with five (5) year warranty ( quote in indian rupees) supply, installation and commissioning of dual head gamma camera spect system, qa and dosimetry items with five year warranty
Tender For supply of electrical items for 111 rcc and 124 rcc d d - change over switch 500 amp , change over switch 200 amp , change over switch 100 amp , fuse kit kat 200 amp , thimble 500 amp , four core copper wire 120 sqmm , four core copper wire 95 amp , four core copper wire 60 sqmm , two core 20 sqmm aluminium wire , change over cut out 500 amp , change over cut out 250 amp , change over cut out 100 amp , change over cut out 50 amp , copper wire 50 sqmm , copper wire 35 sqmm , single core wire two and half sqmm , single core wire 4sqmm , isolator 32 amp , isolator 63 amp , fuse kit kat 500 amp , copper wire one and half sqmm , four core copper wire 25 sqmm , insulation tape , mcb 32 amp , mcb 40 amp , mcb 63 amp , 10 amp 1 way switch , 10 amp 2 way switch , 20 amp 1 way switch , 20 amp 2 way switch , 10 amp 2 pin and 3 pin socket , angle batten holder round , 16 amp 2 pin and 3 pin socket , led bulb 7w , led bulb 9w , led bulb 12w , led bulb 15w , led bulb 18w , led bulb 23 and 26w , angle or batten holder , 16 amp 3 pin plug , pendent holder make anchor or havells , led tube light 4 feet long , led tube light 18 or 20w complete set , double core 10 sqmm wire , extra flexible conduit 25 mm dia pvc black , extra flexible conduit 50 mm dia pvc black , extra flexible conduit 75 mm dia pvc black , electric wire 2 core one and half mm of 100 meter , electric wire 2 core two and half mm of 100 meter , led bulb 01 watt , led bulb 20 watt , hpl led baton , switch 6 amp , binding wire ) /bid number: gem/2025/b/6893946 * /dated: 18-11-2025 & & / bid document1 / 49
Tender For revamping civil infrastructure - construction of maintenance shed, office room and store in one roof, canteen and providing cement concrete flooring for parking area and in tnstc depot at chidambaram - earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification., supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the corporation officials., supplying and filling gravel in layers of not exceeding 15cm thick including watering well ramming and consolidation etc., complete as directed by the corporation officials., providing and laying, spreading and compacting graded stone aggregates to wet mix macadam 250mm thick specification including premixing the materials with water at omc in mechanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in sub base/base course on well prepared surface and compacting with vibratoy roller to acheive the desired density including cost of material, labour charges,rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of morth rev-5 and as directed by the corporation officials., cement concrete 1:5:10 (one cement, five sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification, plain cement concrete 1:2:4 (one part of cement, two parts of sand and four parts of aggregates) using 20mm hbg jelly for flooring including finishing and supplying and fixing tar pad 12mm thick complete as directed by the corporation officials., supplying, fabricating and placing in position mild steel / ribbed tor steel grills for all rcc works as per design given including cost of steel and g.i. binding wire in all floors etc. complete complying with standard specification. (contractor has to make his own arrangements for the supply of steel and binding wire), reinforced cement concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all rcc items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the rcc floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with cement mortar 1:3 (one cement and three sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers, supplying and erecting steel centering including necessary supports for plane surfaces for reinforced cement concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 bg stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (payment for centering shall be given after the concrete is laid), foundation & basement, super structure, brick work using country bricks of size 9" x 4-3
Tender For revamping civil infrastructure -construction of crew rest room, canteen building, office building, and toilet room, providingcement concrete in front of m-shed in tnstc depot at pattukkottai branch in pudukkotail region - towards the hire charges for leveling the heavy undulation portion with using jcb as per the direction of the departmental officers.,the rate including conveyance, fuel, driver charges, providing and laying, spreading and compacting graded stone aggregates to wet mix macadam 300mm thick specification including premixing the materials with water at omc in mechanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in sub base/base course on well prepared surface and compacting with vibratoy roller to acheive the desired density including cost of material, labour charges,rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of morth rev-5supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the corporation officials., dismantling the old damaged building and within the compound in places shown by the departmental officers and clearing and levelling the site, etc.,, brick / stone masonry in cement mortar walls under 3m high, corrugated iron sheet roofing over pan tiles without roof timbers, earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., supplying and filling in foundation and basement with river sand in layers of 15cm thick well rammed and consolidated complying with standard specification etc., complete, supply with serenely gravel in layers of not exceeding 15cm thick including watering well ramming and deconsolidation etc complete, cement concrete 1:5:10 (one cement, five sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification ( the rate is inclusive of necessary planking for panelling whereever necessary and as directed by departmental officers), plain cement concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers., steel centering to the sides and of all the rcc works such as lintel waist slab, beams, floor slab, roof slab and other simulation work with necessary strut and cross bracing including removing the same of curing time of concrete without damaging the rcc works in all floors up to 4.5m height etc. complete as per tnsps., supplying, fabricating and placing in position mild steel / ribbed tor steel grills for all rcc works as per design given including cost of steel and g.i. binding wire in all floors etc. complete complying with standard specification. (contractor has to make his own arrangements for the supply of steel and binding wire), brick work using country bricks of size 9" x 4-3/8" x2-3/4" in cement mortar 1:5 (one cement and five sand) including curing neat finishing, etc., complete complying with standard specifiction complete., rate for foundation & basement, rate for super structure, reinforced cement concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all rcc items of works excluding cost of reinforcement grill and fabricating charges, centering and shut
Tender For certain repair replacement of overhead tank and covers float valves cleaning of ug oh rcc pvc tanks and miscellaneous items under ge (nw) nofra
Tender For auction sale of land - item no.1 all that piece and parcel in mathigiri village of hosur taluk and attached to kelamangalam sub registration district and krishnagiri registration district of krishnagiri district. i. survey number 802/1, dry extent hect 0.45.0, asst.rs .2.22n, now subdivided as survey number: 802/1a1 dry extent hect.0.08.0, asst.rs.0.40np in ac.0.20 cents full extent ii. survey number 799/4, dry extent hect.0.51.0, asst.rs. 2.52np, now subdivided as survey number: 799/4b, dry extent hect.0.32.5, asst.rs. 1.61np in ac.0.80 cents full extent the above said properties have been converted into residential house sites in which a. plot no.2, measuring an area of 2,398 square feet or ac 0.05 1/2 cents of land including common rights of all roads and in this constructed rcc building measuring a total plinth area of 2.200 square feet or 205 square meters with all doors, windows, electrical installations in service connection no.070-0091756, water connections fixtures and other accessories etc, covered under survey number: 802/1a1, now subdivided as survey number: 802/1a1c, dry extent hect 02.20, asst rs. 0.11np. b. plot no. 5, measuring an area of 3,924 square feet or ac.0.09 cents covered under survey number: 799/4b, now subdivided as survey number 799/4b3, dry extent hect.0. 3.60, asst rs 0.18np c.plot no.6a, measuring an area of 2,180 square feet or ac.0.05 cents covered under survey number: 799/4b, now subdivided as survey number 799/4b5, dry extent hect.0.2.00, asst.rs.0.10np d. plot no.6b, measuring an area of 1,744 square feet or ac.0.04 cents covered under survey number: 799/4b, now subdivided as survey number: 799/4b4, dry extent hect.0.1.60, asst.rs.0.10np e. plot no.7, measuring an area of 3,924 square feet or ac.0.09 cents covered under survey number: 799/4b, now subdivided as survey number 799/4b8, dry extent hect.0. 3.60, asst.rs 0.18np f. plot no.8, measuring an area of 11,772 square feet dr ac.0.27 cents covered under survey number: 799/4b, now subdivided as survey number 799/4b9, dry extent hect.0 10.90, asst rs.0.54np. altogether items making a total extent of 25,942 square feet or ac.0.59 1/2 cents situated with the following common boundaries east: road and approved site no 42 belonging to vendee and private property west: land in sy nos 799/2b, 799/2a & 799/1c north: land in sy nos 29799/4b2 & 802/1a1b belonging to others south: land in survey nos 800 & 802/2a belonging to private parties within these boundaries lands measuring a total extent of 25,942 square feet or ac. 0.591/2 cents (twenty five thousand nine hundred and forty two square feet or fifty nine and half cents).item no.2 in mathigiri village of hosur taluk and attached to kelamangalam sub registration district and krishnagiri registration district of krishnagiri district and also attached to the municipal limits of hosur municipality survey number 799/4 dry extent hec.0.51.0, asst.rs.2.52 np.( in ac.1.26 cents), out of this new sub division survey number 799/4-b dry extent hec.0.32.5, asst rs.1.61 np, (in ac.0.80 cents) which has been converted into a layout comprising various house sites, out of this the house sites bearing plot no.4 measuring an area of 3924 square feet (or) extent ac.0.09 cents and situated within the following boundaries on the eastern side: 20 feet common road on the western side: survey numbers 799/2b and 799/2a on the northern side: plot no.3 on the southern side: plot no.5 item no.3 in mathigiri village of hosur taluk and attached to kelamangalam sub registration district and krishnagiri registration district of krishnagiri district and also attached to the municipal limits of hosur municipality survey number 802/1 day extent hec.0.45.0, asst. rs.2.22 np.( in ac.1.11 cents) out of this new sub division survey number 802/1a1 dry extent hec.0.08.0, asst rs.0.40 np.( in ac.0.20 cents) which has been converted into a layout comprising various house sites, out of this the house sites bearing plot no.1 mea