Get complete information related to latest Rpm Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rpm Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rpm Meter Tenders.
Tender For supply of low voltage card section , high voltage module type , area gamma radiation indicating meter with auto ranging type , mains transformer with line filter card type , detector assembly , 6 digit degital electromagnetic counter 12 v , photo-multiplier tube
Tender For corrigendum : supply of fixed contact assembly 400a part no bd 4510 , arc control pot separator part no ek 6050876 , barrier part no ek 6050869 , insulated bolt big part no pd 420 , insulated bolt small part no pd 8296 , carriage assembly complete 400 630a part no bd 5550 , moving contact assembly part no bd 5551 , jaw contact assembly set part no bd 4050 , auxiliary plug and socket assembly complete set part no bd 4850 , guide pin big part no pd 4043 , guide pin small part no pd 3597 , lead screw assembly part no bd 4860 , operating mechanism complete set part no bd 4911 , rod holder assembly part no bd 4921 , shunt trip coil assembly part no 1650ts , isolating spout assembly with nylon shroud part no bc 9977 , elr core balance current transformer part no ea 6650 , power pack unit 110v dc part no bd 5999 , instrument chamber box complete with internal wiring including selector switches, indication lamps voltmeter, ampere meter, fuse base etc part no bdw 7771 , partition plate assembly part no bd 5255 , operating shutter assembly part no bd 5310 , gas van pipe part no bd 5589 , ocb tank partition part no bd 4711 , earthing bar contact part no bd 8810 , cable entry box part no bd 2290 , idmt relay complete set with 2 over current and 1 earth fault with instantaneous tripping high set part no ea 6561 , high speed tripping relay part no ea 6890 , assorted hardware part no bd 9295 , under and over voltage relay part no ea 6591 , heavy duty earth leakage relay with leakage display time lag facility and cbct part no ea 6641 , trolley complete with all accessories part no bd 8268 , rotary switch complete with link and fixing plate part no bd 9191 , complete wiring set part no bd 5988
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpmmeter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpmmeter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For tender for supply of enm electrical spares item - potential transformer 11kv110v heavy du , volt meter range 0 11kv analog , square , ampere meter range 0 150a analog square , current ratio 100 50 5 5a suitable for fitting in vcb , relay erth lkge 15a prmry 0 5a primary side calibration and fitting required , potential transformer 11kv 110v 3ph
Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint
Tender For auction sale of iron scrap,iron cable drum,empty oil drums,ct & pt combined unit,acsr conductor off sizes (uninsulated),pvc aluminium cable,choke all size,copper,ocb complete,scrap corrugated box,ct off sizes,xlpe cable all sizes,plastic meter box,ignitor,pvc flexible wire all sizes,vcb incomplete,plastic meter seal,scrap plastic (low grade),copper cable scrap,shunt capacitor - off sizes,joint box all size,metering cubical,electric motor of all sizes,ceiling/wall fan,distribution box - ltdst board pwr distr box typ:1 f/100kva,water cooler(e waste),scrap transformer oil with drum(hazardous),scrap transformer oil(hazardous),single phase meter electronic (e-waste),poly phase meter electronic (e-waste),fluoroscent tubes(e-waste),hpsv lamps (e-waste),misc items (refer annexure-1) punjabi bagh,iron - acb body ( refer annexure-2),ring main unit incomplete 3 way (refer annexure-3),ring main unit incomplete 4 way (refer annexure-3),iron (ring main unit) (refer annexure-4),misc items ( refer annexure-5) budella 1
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For corrigendum : procurement of spares for telangana substation transformers for st iienabling works - hv bushing, lv bushing, oti meter rtd type, : wti meter rtd type, gor-ii, mog, prv, valve set, silica gel breather, hv support insulator, lv support insulator, transformer oil, gasket set, aircell bag, nct with bushing
Tender For repair maint of fan electric meter geyser external electrification maint of transformer vcb and lt ug cable and allied works in cfees rac under zone b at kwc area under ge i rnd delhi