Get complete information related to latest Rpr Test Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rpr Test Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rpr Test Kit Tenders.
Tender For supply of 3dof drone stability test jig with proprietary software , 2dof drone stability test jig with proprietary software , battery charging , testing station , drone sensor training platform
Tender For supply of simulator workstation with rugged controller , drone simulator software licence standard , high fidelity simulator workstation with rugged controller , 3d simulation software licence advanced , vr headset 6 dof and sim compatible , trainer workstation with instructor simulator , 55 inch led display for trainer workstation , networking cabling and power management lan plus ups , workstation desk and ergonomic chair set , split air conditioner 1 and half ton , posters flex banners and cut section models , printer brother t4500 , high performance cad workstation , fdm 3d printer bambu h2d with ams combo , fdm 3d printer bambu h2s with ams combo , fdm 3d printer bambu x1 carbon with ams combo , filaments abs tpu pla plaplus assorted , filament dryer creality space pi x4 or equivalent , resin 3d printer prusa sl 1s or equivalent sla or msla with resin material , industrial 3d scanner creality otter or equivalent , laser engraver and cutter machine 40 watt , wooden tables chairs and workbenches set of 06 , power management fitting and backup inverter 2 kva , advanced drone repair equipment soldering station digital microscope esd mats oscilloscope , drone electronics sensors and spares kit , storage almirahs lockable , posters flex banners and cut section models , 3 axis drone stability test jig with proprietary software , bldc motor thrust test bench with proprietary software , drone sensor integration and testing equipment , gps testing equipment with proprietary software , flight controller assembly programming station , propeller balancer , battery charging and testing station , battery repair station , drone and 3d printer service tools , soldering and rework station yihua 982d iii or equivalet , esd workbenches , workstations for tuning or programming , line of sight trainer uav with controller , vtol trainer uav with mission planner tricopter or quadcopter , fixed wing trainer uav with mission planner , fixed wing vtol uav system with day and night camera dooaf module , day and night enabled quadcopter with dooaf capability , surveillance and payload delivery drone with mission planner hexacopter or octacopter , storage box for drones and accessories , storage almirahs , lab tables and workstations with storage , split air conditioner 2 ton , interactive panel 75 inch or larger 4k uhd, multi touch with ops , 55 inch led display , study chairs with ergonomic and stackable , split ac 1 and half ton , 20 day training programme for 15 individuals with flying repair fabrication with study material , soccer drones with propeller cage , soccer drone arena including netted enclosure with goal posts //bid details 2 / 41
Tender For refer tender notice - purchase of non consumable item in material testing lab for civil department - torsion testing machine (code e006)function: conducts torsion and twist tests on materials. such as metal wires, tubes, and sheetstorque measurement : pendulum dynamometer systemtorque application : geared motor through a gearboxtorque range : adjustablematerial tested :metal wires, tubes, sheet materialsfloor-mounted electromechanical type,230 v ac, 50 hz power supply,digital display, sand replacement test apparatus (or) core cutter devices(code e014)metal tray / base platesquare metal tray with a central hole (e.g., 300 mm 300 mm with 100 mm hole).another common size: 450 mm square, 50 mm deep with 200 mm central hole for larger kits seamless steel cylinder with no sharp edges.common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1wall thickness ~3 mm (industrial products), total station with all accessories(code e022)leica flexline ts10 reflectorless total station angle accuracy: 1 5 (smaller values = higher precision). magnification: ~28x 30x optical zoom. distance range:with prism: 2,000 m 6,000 m+reflectorless: 600 m 2,000 m typical. battery backup: ~12 36 hrs field operation., rockwell cum brinell hardness testing machine with intentor set box(code e031)min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories:steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine
Tender For rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagent
Tender For corrigendum : supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear water pumping station and supply of 1 no empty chlorine tonner at ibs uporgora under chhatna, saltora block sub-surface water based piped water - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess
Tender For corrigendum : supply delivery and fitting fixing of gaseous chlorination items for the standby system of clear water pumping station and supply of 1 no empty chlorine tonner at intake kukrakuri under chhatna, saltora block sub-surface water based piped - supply and delivery of gaseous chlorination unit spares (0-10kg) & (0-4kg)kg/hr. require of wallace & triman evoqua, vacuum regulator (wall/cylinder mounted)with auto switchover facility, capacity 0-10 kg/hr max, evoqua make s10k scale controller, capacity 10.0kg/hr, manual control, evoqua make 1 injector suitable for 40 psi backpressure, fitting fixing of the above new supplied spares on the existing position part by part with new ejector pipe line with necessary fitting materials and necessary welding job by expert mechanical complete the job as per direction of eic and as per is:10553., supply and delivery at site of 1000 kg empty chlorine tonner hydraulic test pressure 30 kgf design as per asme section viii div.1 with hot-forged steel hook and a safety tongue piece, add: 18% gst, add: 1% cess