Get complete information related to latest Rpr Test Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rpr Test Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rpr Test Kit Tenders.
Tender For supply of computerized touch screen micro vickers hardness testing machine as per the attached technical specification. make: metrix/shimadzu/future-tech [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For purchase of non consumable item in material testing lab for civil department - torsion testing machine (code e006)function: conducts torsion and twist tests on materials. such as metal wires, tubes, and sheetstorque measurement : pendulum dynamometer systemtorque application : geared motor through a gearboxtorque range : adjustablematerial tested :metal wires, tubes, sheet materialsfloor-mounted electromechanical type,230 v ac, 50 hz power supply,digital display, sand replacement test apparatus (or) core cutter devices(code e014)metal tray / base platesquare metal tray with a central hole (e.g., 300 mm 300 mm with 100 mm hole).another common size: 450 mm square, 50 mm deep with 200 mm central hole for larger kits seamless steel cylinder with no sharp edges.common size: 100 mm internal diameter, 127 175 mm length (varies by kit). mkpequipments.com +1wall thickness ~3 mm (industrial products), total station with all accessories(code e022)leica flexline ts10 reflectorless total station angle accuracy: 1 5 (smaller values = higher precision). magnification: ~28x 30x optical zoom. distance range:with prism: 2,000 m 6,000 m+reflectorless: 600 m 2,000 m typical. battery backup: ~12 36 hrs field operation., rockwell cum brinell hardness testing machine with intentor set box(code e031)min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories:steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine
Tender For purchase of equipments for materials testing lab for civil department - spring testing machineload & displacement sensing load cell capacity: 0 10 kn accuracy: 1% fs (better if 0.5%fs) displacement sensor lvdt / digital encoder accuracy: 0.5 mmmachine design frame: rigid steel frame with crosshead movement type: mechanical screw with hand wheel (simple & robust) or electromechanical actuator (for smoother, controlled motion) crosshead travel: ~150 200 mm safety guards: transparent shields around moving partsfixtures & accessoriesspring testing compression plates (ground & parallel) tension hooks / eyelets for extension springs set of spacers / adapters for small springs tensile testing standard tensile grips wedge or screw type calibration certificate for load cell standards complianceensure compliance with basic material test standards such as: astm e4 / iso 7500-1 calibration of force measurement astm e8 / iso 6892 tensile performance & accuracy load accuracy: 1% fs displacement accuracy: 0.5% repeatability: 0.5%, rockwell cum brinell hardness testing machine min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories : steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine, direct shear machinestandard compliance:the equipment shall confirm to bureau of indian standards is 2720 (part 13) and equivalent astm international astm d3080.technical specifications:shear box size: 60 mm 60 mm 25 mm specimen size (complete with grid plates, porous stones, and specimen cutter).normal load capacity:minimum 5 kn with loading yoke and calibrated loading hanger set.shear load capacity:minimum 2.5 kn or 5 kn with calibrated proving ring (with calibration certificate).rate of strain (shear displacement):variable speed drive with controlled displacement ranging from 0.01 mm/min to 1.25 mm/min (motorised model preferred for uniform rate control).displacement measurement:horizontal displacement dial gauge: 0.01 mm least countvertical displacement dial gauge: 0.002 mm or 0.01 mm least countloading frame:rigid, heavy-duty loading frame with corrosion-resistant finish.drive system:motorised with single phase 220 230 v, 50 hz power supply.accessories (to be supplied complete):shear box assembly, proving ring with calibration chart, two dial gaugesloading weights and hanger, porous stones (2 nos.), specimen cutter, tool kit, flow table test apparatusdimensions and specifications as per is 9103, table top made from flat metal plate, minimm thickness 1.5 mm. table top size: 700 mm 700 mm, with flatness tolerance of 1.5 mm. table top marked with: scribed cross at centre, lines parallel to table edges and central circle of 200 mm diameter underside of table top reinforced to prevent distortion. total mass of table top: 16 1 kg. table top, base frame front and upper stops provided as per is 9103. lower front edge fitted with two rigid stops to transfer load directly to base frame. base frame designed to transfer impact load directly to supporting surface, minimizing bounce. stop watch digital - 2 nos scale 1 mtr 2 nos mounting wooden platform 300 mm height amc for 3 years inclusive.
Tender For supply of software upgradation of digital vickers hardness testing machine , commissioning for software upgradation of digital vickers hardness testing machine
Tender For supply of d cfa re 40 rapid plasma reagin rprtestkit dot the kit should contain the following rpr antigen suspension positive control serum , d cfa re 40 hydroxyzine 10mg5ml bott of 100ml , d cfa re 40 bone marrow harvesting needle small , d cfa re 40 22 g needle with stylet 11 cm length for fnac , d cfa re 40 laryngeal mask airway large medium small , d cfa re 40 long iv line 18 g 100 cm , d cfa re 40 tube endotracheal reinforced pvc size 9 dot 0 with cuff , d cfa re 40 foleys balloon catheter 2 way silicon 16g , d cfa re 40 vaccum blood collection tubes with needles and additives sodium fluoridesodium fluoride k3edta in tubes of vol 02 ml , d cfa re 40 iodinated adhesive incise drape different sizes large , d cfa re 40 iodinated adhesive incise drape different sizes medium , d cfa re 40 iodinated adhesive incise drape different sizes small , d cfa re 40 cling drape film roll sterile transparent dot , d cfa re 40 post operative transparent wound dressing with absorbent pad 10 15cms , d cfa re 40 post operative transparent wound dressing with absorbent pad 10 8cms , d cfa re 40 post operative transparent wound dressing with absorbent pad 5 7cms , d cfa re 40 post operative waterproof flexible conformable dressing 10 15 cm , d cfa re 40 post operative waterproof flexible conformable dressing 10 30 cm , d cfa re 40 bandage abdominal binder with perineal support medium , d cfa re 40 bandage abdominal binder with perineal support large , d cfa re 40 ceftriaxone 250mg inj ) /bid number : gem/2026/b/7576724 * /dated: 23-05-2026 & & / bid document 1 / 22