Get complete information related to latest Safety Breaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Safety Breaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Safety Breaker Tenders.
Tender For annual servicing and overhauling of ht/lt equipment at garvi gujarat, new delhi-servicing and overhauling of vcb operatingmechanism, cleaning of contacts & insulatorsand making circuit breaker electrical operationalfrom tnc switch.testing of 11 kv vcb panels as per test detailsgiven below:a) high pot testing of each pole to checkhealthiness of vacuum interrupter and itsinsulators.b) high pot testing pf main bus bar.c) insulating testing of vcb in close and openposition.d) removing of moisture and sulfation from ct'sspouts and other insulators and providing reinsulation on these parts.e) testing of thermostatically controlled 230v acspace heaters in the ct's and cable endchamber.f) servicing and high voltage testing of the vcb.g) testing and servicing of ct & pt.h) testing and servicing of primary busing rod.i) testing and servicing of bus-bar supportinginsulator 400 amp.j) testing and servicing of rose contact3 nos ``02 testing and calibration of idmt protective relay2 o/current and 1 e/fault for ht and lt panelwith primary injection set.08 nos03 servicing and overhauling of different rating acbof capacity 2000 amp 5nos, 1250 amp 4 nos,operating mechanism, cleaning carbon fromcontacts & insulators and making circuitbreaker electrical operational from switch andsetting of tripping mechanism of acb,adjustment of contact spring and setting ofinbuilt protective device.12 nos04 servicing, testing of capacitor panel of capacity305 kvar i/c calibration of apfcr relay at site.02 nos05 servicing, cleaning and testing of dry type transformer ofcapacity 1250 kva, 11 kv/440 v 3 phase transformerincluding performing the following tests as per is standard:a) ir valueb) magnetic currentc) voltage ratiod) high voltage teste) core balance tests
Tender For supply of 22kv/? 3/110/? 3-110/? 3v single pole voltage/ potential transformer for c&s make breaker panel , 20/1a 10/1 a current transformer for 22 kv kirloskar switchgear panel
Tender For supply of earth leakage circuit breaker, double pole current 25 amp, sensitivity 30 mili amp voltage 2 40v ac edts-118 rev.e.am 2, corr.2. make-, l&t(model no.-bc202503), abb(model no.-fb202), siemens(m odel no.-ssv43120rc) [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of outer smooth clear lens , iclear lens , yellow lens_l , yellow lens_r , gasket for base plate , prism, for rcl _cl_ for centreline lights , prism pad for centreline lights , interference colour filter 47, 5x26, 5x1mm red for centreline lights , o-ring gasket 145, 64 x3, 53 silicon for centreline lights , o-ring gasket 160,0x3 ,0mm silicon for centreline lights , top cover no toe-in for touchdown zone lights , o-ring gasket 145,64 x 3,53 silicon for touchdown zone lights , o-ring 160,0x3 ,0mm silicon for touchdown zone lights , spreader lens clear for approach fitting , spreader lens green for threshold fitting , spreader lens red for stopway end fitting , lamp holder suitable for bi pin halogen lamp , interference colour filter 50,5x18x2 mm red for stopbar light , o-ring gasket 145,64 x 3,53 silicon for stopbar light , upper breakable coupling , lower breakable coupling , lamp , led module , frangible coupling , base plate , constant current regulator 10 kva , constant current regulator 25 kva , 300w 6.6_6.6a isolating transformer , led driver pcb , lamp 45 w, 6.6a halogen , 200w 6.6a bi-pin halogen lamp , lamp 36w , blue lens , idm8000 muc card for ccr , t3 voltage transformer for 4 kva ccr , t3 voltage transformer for 20 kva ccr , t3 voltage transformer for 25 kva ccr , o ring gasket 259.3 x 5.7 for 12 inch shallow base for runway edge inset , gasket for prism for threshold green light , o-ring gasket 219.3x 5.7 viton for threshold green light , reflector lamp 105w_6.6a for approach inset light , papi tl kit incldng clinometer spnr of corrct size aln key algnmnt tl and lftng hook , male_female receptable plugs for primary cables , output voltage transformer , mimic panel , diode byv6c , isolatorswitch , circuit breaker , medium power npn silicon high current transistor , power masfet , varistor v20k275 , riu ops , essential-6 pcb patch pannel unscreened 24 rj45 cat6 rear connect black , connection interface assembly , motor starting , cooling fan bid details/ 2 / 51
Tender For auction sale of taph metal cutting tube- corton steel (grade of material: sa 178 gr.a),iron scrap (m. s. scrap) (esp collecting electrode plates ),iron scrap (m. s. scrap) (mix scrap),iron scrap (plate & steel structure),iron scrap (m. s. scrap) (machinery parts, old valve, hangers, etc),light m.s.scrap (light ms sheet scrap & mix scraps),pvc carbo,dc battery bank & auto batteries,electrical scrap,copper scrap ( chips, ac pipe, strip),bearing scrap,s.s. scrap,electrical cable (copper) scrap,electrical cable (alluminum) scrap,conveyor belt scrap,plastic item,rubber scrap,fire van hose pipe without nozzle,frp scrap (frp blade & pipe),g.i scrap,titanium (phe plate & pipes) scrap,e-waste scrap items,capacitive voltage transfarmer,circuit breaker,ceiling fan 48 with or without blades,
Tender For supply of boq for spares of switch gear of mcc - 230vac,power contact,rating 12amp.,type 3rt2024- 1al20,make siemens , power contactor coil volt 230vac,power contact,rating 09 amp., type 3rt2024- 1bb40-0cc0,make siemens , motor protection circuit breaker range 35 - 45 amp. type 3rv2131-4va10,make siemens, , open execution switch, with rotary operating mechanism, type 3rv19361b-z,make siemens, , open execution switch, with rotary operating mechanism, type 3rv19261b-z,make siemens, , aux.contact 2no,type 3rv2901-1b,make siemens, , motor protection circuit breaker range 32 - 40 amp. type 3rv2131-4ua10,make siemens, , motor protection circuit breaker range 27 - 32 amp. type 3rv2121-4ea10,make siemens, , motor protection circuit breaker range 22 - 32 amp. type 3rv2131-4ea10,make siemens, , motor protection circuit breaker range 16 - 22 amp. type 3rv2121-4ca10,make siemens, , motor protection circuit breaker range 10 - 16 amp. type 3rv2111-4aa10,make siemens, , motor protection circuit breaker range 9 - 12.5 amp. type 3rv2111-1ka10,make siemens, , motor protection circuit breaker range 5.5 - 8 amp. type 3rv2111-1ha10,make siemens, , motor protection circuit breaker range 3.5 - 5 amp. type 3rv2111-1fa10,make siemens, , motor protection circuit breaker range 2.8 - 4 amp. type 3rv2111-1ea10,make siemens, , motor protection circuit breaker range 2.2 - 3.2 amp. type 3rv2111-1da10,make siemens, , motor protection circuit breaker range 1.4 - 2 amp. type 3rv2111-1ba10,make siemens, , motor protection circuit breaker range 0.9-1.25amp. type 3rv2111-0ka10,make siemens, , motor protection circuit breaker range 0.28-0.4 amp. type 3rv2111-0fa10,make siemens, , four change over relay,coil voltage 230vac,with base and with coil type 7rq0100- 0dr00,make siemens , base of change over relay type 7rq0201-1dx00, make siemens
Tender For corrigendum : supply of goods, tools & equipmentforan international standard itotin electrician tradeat iti vyara, gujarat, india - electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines (single phase and three phases). should be fitted with friction brake arrangement, dynamometer, and instrument panel and power supply unit., motor-generator (ac to dc) consisting of: squirrel cage induction motor with star-delta starter and directly coupled to dc shunt generator and switch board mounted with regulator, air breaker, ammeter, voltmeter, knife blade switches and fuses, set complete with case iron and plate, fixing bolts, foundation bolts and flexible coupling. induction motor rating: dc shunt generator rating: induction motor rating: dc shunt generator rating:, motor generator (dc to ac) set consisting of-shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed plate, fixing bolts, foundation bolts and flexible coupling. shunt motor rating: ac generator rating:, linear i.c. trainer, digital i.c. trainer, component of typical small hydro power, component of typical water mill, low voltage control and systems. with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, residential and small business systems with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, building control systems and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, industrial control system and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, solar system lab suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, training system predictive maintenance and condition monitoring of electric drives, electric vehicle motors and battery training & test bench, industrial electrical testing facility with circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the testing by the student, ar-vr training set up., portable electric drill machine, pillar electric drill machine, outside micrometer, motorized bench grinder, rawl plug tool & bit, hydrometer, thermometer, soldering iron, copper bit soldering iron, de soldering gun, table vice, ohm meter; series type & shunt type, stock and dies conduit, multi meter (analog), digital multi meter, a.c. voltmeter, milli voltmeter, d.c. milliammeter, ammeter, a.c. ammeter, a.c. ammeter, kilo wattmeter, a.c. energy meter, power factor meter, frequency meter (analog + digital), tachometer with stopwatch, current transformer primary-, potential transformer, growler internal+ external, tong tester / clamp meter, megger, wheat stone bridge with galvanometer & battery 2 nos, earth tester
Tender For microprocessor based agent release panel. as per following specifications: 1) fas-nap contr ol panel with isolator module and relay trigger unit- control by manual input with breaker switch operated e lectric solenoid valve npt normally closed nc direct action ac 220v for varied fluids (2w160-15 1/2") the direct-acting type diaphragm structure without pressure to open, to extend the using field using the plate d iaphragm structure for opening and closing. operating pressure: 0kg/cm2 to 10kg/cm2. medium: temperat ure: -5c to + 80c; type: normally closed, operates on 220 vac supply battery backup with built in chargin g, 16 x 2 lcd dot matrix display evacuate and key pad enable, disable facility. low battery visual warning with audible tone, relay output for actuators, provision for remote fire with audio / visual indications. com patible to all types of conventional detectors, zone disable (isolation) facility with loop voltage cut off, rese ttable 24 vdc output for 4 wire detectors, three 24v sounder output (fire, after cross zone, after gas relea se), two mode operation facility (auto / manual). programmable solenoid output with on and off timer. pr ogrammable main / standby cylinder output facility, gas inhibit and instant release facility. manual gas rel ease with or without timer. actuator pressure low sensing facility, rs 485 output for repeater. qty - 2 nos/s et. detailed specification and diagram as per annexure attached. make: re-120gr agent release panel or equivalent. [ warranty period: 30 months after the date of delivery ]