Tender For supply of 1_power module -part no -fa _ 5_ ps 501 of _ safeway securitysystems make panel for fire alarm and extingushant _gas_ release panels as per attach boq specification,2_monitor module card-part no. _fa_5_mm _502-b of safeway securitysystems make panel for fire alarm and extingushant _gas_ release panels as per attach boq specification,3_control module card -part no. _fa_5_cm_503-a of safeway securitysystems make panel for fire alarm and extingushant_gas_release panelsas per attach boq specification,4_zone module card- part no._ fa_5_zm_504-c of safeway securitysystems make panel for fire alarm and extinguishant _gas_ release panels as per attach boq specification,5_mode selector module card -part no. _fa_5_m_517-b of safeway securitysystems make panel for fire alarm and extinguishant_gas_release panels as per attach boq specification,6_dv module card-part no. _fa_5_dv_520 of safeway securitysystems make panel for fire alarm and extinguishant _gas_release panels as per attach boq specification,7_gas module
Tender For operation and maintenance of enm installations of internal and external electrification dg sets eot cranes air conditioners water supply water treatment plants sewage treatment plants fire alarm fire fighting systems water cooler
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - hospital; operation & maintenance charges for addressable type fire alarm fire detection and fire fighting systems smoke extraction, water mist systems and other relevan..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - hospital; item rates for spares required for maintenance of part b; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - hospital; scrap value of part-c; service provider
Tender For supply of deluge system equipment for msb unit for nrep - a. deluge water spray systems (mvws system + water curtain system + hvws system)cs deluge valve with dry pilot trim & electric release trim, horizontal inlet & horizontal outlet, without skid, ul/fm approved, complete with dry pilot trim with test, alarm & drain devices, local deluge valve control station (dvlcs) (1 no. per dv), pressure transmitters (02 nos per dv.), 3/3 way sil2 certified intrinsically safe solenoid valve-24v dc (1 no. per dv), pressure gauges (03 nos. per dv), air filetr regulator (afr)(1 no. per dv), air vessel of adequate capacity (1 no. per dv), etc. in compliance with the scheme shown in attached "technical data sheets for fire fighting & safety equipment (tk-1p21a-sa-dat-0001)".the deluge valves shall be supplied with the trim and associated instruments duly assemblied with the deluge valve and with suitable packaging to avoid damage during transportation. the upstream strainer, block valves and by-pass valve including the pipes connecting to these items are not in bidders scope of supply.all items shall be suitable and certified for zone 1,iic,t3 area classification. all electrical and instruments shall be certified for intrinsically safe (ex-ia) and solenoid valve shall be certified to explosion proof (ex-d). all instruments and enclosures (junction boxes/ cabinets/panels/ accessories) in field shall be dust proof and weather proof with ip-67., 200 mm nb, 150 mm nb, 100 mm nb, 80 mm nb, mvw spray nozzle with 1/2" mnpt end connection, moc - stainless steel, ul / fm listed, (with inbuilt strainer): size 15 nb, mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-41, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-79, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., quartzoid bulb detect
Tender For construction of administrative building rcc gplus 2 and provision for rcc g plus 4 for rmc guwahati at ulubari guwahati including water supply and sanitary installation including iei and fans diesel generator set sub station lift fire fighting and fire alarmsystems solar system and security light etc sh- enagagement of data entry operator at office of the assistant engineer-elect gesd-i cpwd guwahati-21subwork/packages:engagement of data entry operator at office of the assistant engineer elect gesd-i cpwd guwahati-21