Tender For design, supply, installation, testing and commissioning (dsitc) of microprocessor based securityalarmsystem for the bank’s main office building at fort, mumbai (date of nit available: may 22, 2026)
Tender For providing of custom bid for services - repair and maintenance of loop network card for fire alarmsystem at swac & armoury at vsn chiloda gandhinagar
Tender For construction of 400 bedded boys hostel building at jipmer campus, puducherry. (civil work): building portion including internal water supply lines, sanitary installation, drainage, demolition of existing quarters and other development works. (electrical and mechanical installation): package c1: providing internal ei, c2: providing fire alarmsystem, c3: providing firefighting system, c4: providing cctv, c5: providing 3 nos. 13 passenger lift, c6: providing 5000 lpd solar water heater, c7: providing network, (agreement no.32/ee(puducherry)/cpwd/2023-24) sub head: risk and cost under clause 14 for providing 2nos. 13 passenger lift.subwork/packages:electrical
Tender For tender for supply of signal module , manual call point siga 270 edwards , electronic hooter , power supply card , fire alarming loop card , fire alarm module-3-cpu3 , isolator module , communication card , fire network communication card , control relay module , monitor module interface unit
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For notice inviting tender for non-comprehensive annual maintenance contract for branches/office under ghaziabad region for cctv, securityalarmsystem & fire alarmsystem
Tender For bid to ras supply of sitc control panel 10 loops , sitc control panel 4 loops , sitc control panel 2 loops , sitc of network module. the module shall connect panels and repeator panel , sitc of active repeater panel to be integrated , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitc of addressable multi sensor with co detection , sitcc of response indicator on surface , sitc of short circuit isolator module , sitc of analogue addressable dual action manual call point , sitc of addressable horn strobe with a maximum output , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls, above false ceilin , dismantling of fire alarm and detection system , supply and fixing in replacement of earth continuity conductor , dismantling of old unsv control panel , demolition of wall and ceiling board , supply and fixing of suspended system ) /bid number : gem/2026/b/7339023 * /dated: 18-03-2026 & & / bid document 1 / 19
Tender For tender for supply of fire alarm and smoke detector -1 loop supply of fire alarm panel with battery & network card (p-9940a) , supply of smoke detector , supply of heat detector , supply of manual call point , supply of hooter with strobe , supply of 650 va with in-built battery ups , installation , testing & commissioning , supply of 1.5sqmm 2 core armored cable , supply of 25mm pvc conduit pipe , laying of 1.5sqmm 2 core armored cable , laying of 25mm pvc conduit pipe