Get complete information related to latest Security Door Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Security Door Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Security Door Tenders.
Tender For supply and installation of kitchen equipments for hostel mess at indian institute of science, bengaluru - dry store, ss platform digital weighing scale.ss platform of size 600 x 600mm, power supply - 230v ac, 50 hz, display colour/digit - red/ green/ 6 digits, display size - 0.56" (14.22 mm), number of keys - 5 keys, battery - 6v / 4ah,, mobile ingredient bin mobile ingredient bin with slant top, sliding lid, castors & scoop.37 gal. (140 l) slant top, with scoop, a hygienic clear sliding lid, bins should made of nsf-listed, fda-accepted material, bins has to be designed with a slanted top to easily access product., ss low height platform rack (dunnage rack).38 x 38mm pipe frame structure, 38 x 38mm pipe cross support with a spacing of 70mm, 6 nos leg of 38mm sq. ss legs fitted with adjustable nylon bullet feet., ss storage rack with 4 shelves.18swg ss shelves double beaded on all sides, reinforced with 25 x 100 x 25mm hat channels, dia 38mm ss round legs fitted with adjustable nylon bullet feet., walk in cooler, walk-in cooler, +2 deg c to +8 deg c.unit should be made from 60 mm thick prefab rigid puf sandwich panels with 1mm thick ss 304 grade sheet outside and inside, the cold room should be with ceiling and wall panels interlocked through a cam lock mechanism, fitted with a hermetic sealed compressor. the condensing unit should be split type, which is air cooled. swing type and insulated door having magnetic gasket, safety latch, lock and heavy duty hinges. the room should maintain a temperature of +2 c to +8 c. all accessories like light, light switch, emergency switch, door heater, vacuum release, temperature indicator to be provided with the unit. the refrigerant used should be r 134a. flooring inside the cold room is kottah stone flooring (flooring in client scope)., perforated storage rack with 4 shelves.16swg ss shelves double beaded on all sides with perforation in entire length and width, 50 x 5 mm perforation with a spacing of 15mm, stiffed with 25 x 100 x 25mm hat channels, 38mm ss round legs fitted with adjustable nylon bullet feet., veg prep area, ss work table with 2 sink unit & 1 u/s.16swg ss sunken top double beaded on all sides, reinforced with 25x25mm ss pipe frame structure, 2 nos sink of size 450 x 450 x 300mm deep, radius corners, fitted with 38mm waste coupling, 150mm splash guard on rear and (left/right) sides, 18swg ss under shelf reinforced with ss channel with 150mm clear gap from ffl, properly soundeadned, 38x38mm sq ss legs fitted with adjustable nylon bullet feet., mixer faucet, single hole, deck mount mixing faucet.single hole deck mount mixing faucet with polished chrome plated brass body, 10 1/8" swing nozzle with full flow laminar flow device, quarter-turn ceramic cartridges, lever handles, 18" flexible stainless steel supply hoses with 1/2" npsm / 5/8" o.d. compression connections. certified to asme a112.18.1\csa b125.1, nsf 61-section 9 and nsf 372. meets ada ansi\icc a117.1 requirements., single hole single temperature deck mount faucet for ro watersingle hole single temperature deck mount faucet with polished chrome plated brass body, 5 7/8" swivel gooseneck, 2.2 gpm aerator, ceramic cartridge, lever handle and 1/2" npsm male inlet. certified to asme a112.18.1\csa b125.1, nsf 61-section 9 and nsf 372. meets ada ansi\icc a117.1 requirements., chopping table with 1 u/s.full length and full width 40mm food grade nylon chopping board supported by ss angle frame, 150mm rear splash on rear side, 18swg ss under shelf reinforced with ss channel with 150mm clear gap from ffl, properly soundeadned, 38x38mm sq ss legs fitted with adjustable nylon bullet feet., ss work table with 2 u/s.16swg ss top double beaded on all sides, reinforced with 25x25mm ss pipe frame structure, 150mm splash guard on rear side, 18swg ss under shelf reinforced with ss channel with 150mm clear gap from ffl, properly soundeadned, 38x38mm sq ss legs fitted with adjustable nylon bullet feet., commercial knife sterilize
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For a/r & m/o to residential qtrs. at sc-408 & sc-409, pushp vihar, sector-vii, m.b. road, new delhi dg. 2024-25.(sh:- provide & fixing of iron window, wiremesh window, glass windows and securitydoors for attending major complaints).subwork/packages:sh:- provide & fixing of iron window,w iremesh window, glass windows and securitydoors for attending major complaints.
Tender For purchase of assessment and therapy equipments for 15 sub divisional one stop centers - schedule 1 : sensory integration & developmental - aids and appliances, ball pool, balls soft plastic, puppets, bean bag (type - 1), bean bag (type - 2), clay-play doh, exercise floor mat (plinth), floor mat with different textures, granules with different textures, sensory bottles, stepping stones, triangular steeping stone, audible cricket ball, bosu ball, playthings (ball, sensory ball small), medicine ball, non-sterile standard wooden tongue depressor, oro-motor and sensory kit set 1, scooter board, sensory ball, sensory board, door latch frame set, light setting for the sensory integration room, lighting objects for establishment of sensory integration room, adl activities materials, fluorescent stickers, swing (type 1), swing (type 2), sponge stamping wood
Tender For supply of set of double side swing doors confirming to icf specification no. icf/md/specn.-268. (1) double side swing door assembly (alu. door with s.s fixing frame) to icf drawing no.-icf/sk3-5-6-014 col-i alt.-h/nil, qty.-1 no/set. (2) double side swing door assembly (alu. door with s.sfixing frame) to icf drawing no. icf/sk3-5-6-014 col-ii alt.-h/nil, qty.-1 no/set. mat. specn. as per drg.
Tender For provision of securitydoor lift pressurization and securitydoor engineering of staircase and lobby at dhh dhenkanal for compliance of shortfall of alsbm system