Get complete information related to latest Security Feature Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Security Feature Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Security Feature Tenders.
Tender For purchase of lab equipments for ice dept - purchase of lab equipments for ice dept, i/p and p/i converter (iemcode:g002) i/p converter:(4 20) ma to (3 15) psi conversion. p/i converter:(3 15) psi to (4 20) ma conversion. air filter regulator (afr):20 psi regulated air supply. built-in current source. 3 digit led display for process indication. power supply: 230 v ac, 50 hz. mounting:bench-top / panel-mounted trainer configuration., level measurement using float and sight glass indicator- itemcode: g005specifications: sight glass level indicator. float type level indicator. power supply:230 v ac, 50 hz. monoblock pump:0.5 hp / 1 hp. sump tank., 8051develop ment board with usb/rs 232 cable to connect with computer (item code: g008)specifications: communication interface:usb / rs-232. on-board facilities:8 output leds,8 input switches,ldr,reed switch,8-bit adc,8-bit dac. display interfaces:seven-segment display,16 2 lcd interface. motor interfacing:stepper motor with driver,dc motor with h-bridge driver, 8 bit adc/dac interface board (item code: g009)specifications: thermistor / lm35 input in one channel. variable input (0 5) v in another channel. 8 leds for digital output indication.. necessary control signals provided for adc0809. 8-bit dac using dac0808. 8-bit digital input from controller. single-channel dac output:(0 10) v. power supply: 12 v or 15 v for analog circuitry, water level measurement trainer kit using capacitive type transducer (item code: g020) tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20) ma and/or (0 5) v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement., flow measurement using electromagn etic flow meter(item code: g021)specifications: medium: water (salt water / bore well water). electromagnetic flow measurement: instantaneous flow rate and totalized flow indication. electromagnetic flow meter: integral mounted type. power supply: 90 260 v ac, 50 hz. minimum media conductivity: 15 s/cm. flow rate unit: m /hr. operating pressure: up to 10 kg/cm . electrode material: ss-304 / ss-316 / ss 316l. lining material: ptfe / neoprene / hard rubber / pfa. line size: 15 nb 25 nb. flow range: 0.1 10 m /hr. connection type: flanged. display: digital indication for flow rate and totalized flow. water pump: submersible type, 230 v ac, 50 hz. water tank: approximately 20 25 liters capacity. flow control valve provided. drain valve and overflow arrangement provided. mounted on powder-coated ms frame suitable for laboratory use.
Tender For tender for supply of vao card , door hatch sensor , vdmc , serial expension card , vrtu fan chassis , 12v power supply for vrtu , 5v power supply for vrtu , 16 slot vme chassis system , serial card rs232+rs485 tab 5 , marine isolator , battery pack for ups , ruggedized , 2.4kw dc ups power unit , keyboard , rugged panel mount 2 in trackball , gauge 48 mm 0 to 10 bar , gauge 48mm 0 to 150 c , gauge 48mm 0 to 750 c , gauge 72mm 0 to 10 bar , gauge 72mm 0 to 1250 rpm , gauge 72mm 0 to 1250 rpm with backlit , gauge 96 mm 0 to 250 rpm , gauge 96 mm 0 to 250 rpm with backlit , gauge 96 mm 20 to 40deg , top mount level transmitter normal temp , side mount leval transmitter normal temp , top leval transmitter high temp for bilge , top leval transmitter ht ss316 , side leval transmitter high temp , flood switch , totaliser for flow meter , pressure transducer (0-6 bar) , pressure transducer (0-10bar) , pressure transducer (0-250 bar) , portable operating unit , heat detector , lonisation smoke detector , optical smoke detector , marine mounting base , i.s lonisation smoke detector , i.s optical smoke detector , addressable base for is type sensors , i.s galvanic barrier , eeot - dial type for engine room , eeot gong for engine room , eeot- push button type for ops , vrtu power redundancy diode , rugged panel mount 20 1 in lcd monitor , network switch , sfp module for network switch , cctv external camera , trigger pcb transciver , modulator 25 kw transceiver , data interface & processing unit type 2 , vrtu console signal splitter (2 pole relay)
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For supply of memu item :- oil flow sensor part no. n0284517 suitable for 3 phase ac memu siemen's make transformers model no. gp 194, type- efat 6144, icf medha. [ warranty period: 30 months after thedate of delivery ] ]
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of equipments for materials testing lab for civil department - spring testing machineload & displacement sensing load cell capacity: 0 10 kn accuracy: 1% fs (better if 0.5%fs) displacement sensor lvdt / digital encoder accuracy: 0.5 mmmachine design frame: rigid steel frame with crosshead movement type: mechanical screw with hand wheel (simple & robust) or electromechanical actuator (for smoother, controlled motion) crosshead travel: ~150 200 mm safety guards: transparent shields around moving partsfixtures & accessoriesspring testing compression plates (ground & parallel) tension hooks / eyelets for extension springs set of spacers / adapters for small springs tensile testing standard tensile grips wedge or screw type calibration certificate for load cell standards complianceensure compliance with basic material test standards such as: astm e4 / iso 7500-1 calibration of force measurement astm e8 / iso 6892 tensile performance & accuracy load accuracy: 1% fs displacement accuracy: 0.5% repeatability: 0.5%, rockwell cum brinell hardness testing machine min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories : steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine, direct shear machinestandard compliance:the equipment shall confirm to bureau of indian standards is 2720 (part 13) and equivalent astm international astm d3080.technical specifications:shear box size: 60 mm 60 mm 25 mm specimen size (complete with grid plates, porous stones, and specimen cutter).normal load capacity:minimum 5 kn with loading yoke and calibrated loading hanger set.shear load capacity:minimum 2.5 kn or 5 kn with calibrated proving ring (with calibration certificate).rate of strain (shear displacement):variable speed drive with controlled displacement ranging from 0.01 mm/min to 1.25 mm/min (motorised model preferred for uniform rate control).displacement measurement:horizontal displacement dial gauge: 0.01 mm least countvertical displacement dial gauge: 0.002 mm or 0.01 mm least countloading frame:rigid, heavy-duty loading frame with corrosion-resistant finish.drive system:motorised with single phase 220 230 v, 50 hz power supply.accessories (to be supplied complete):shear box assembly, proving ring with calibration chart, two dial gaugesloading weights and hanger, porous stones (2 nos.), specimen cutter, tool kit, flow table test apparatusdimensions and specifications as per is 9103, table top made from flat metal plate, minimm thickness 1.5 mm. table top size: 700 mm 700 mm, with flatness tolerance of 1.5 mm. table top marked with: scribed cross at centre, lines parallel to table edges and central circle of 200 mm diameter underside of table top reinforced to prevent distortion. total mass of table top: 16 1 kg. table top, base frame front and upper stops provided as per is 9103. lower front edge fitted with two rigid stops to transfer load directly to base frame. base frame designed to transfer impact load directly to supporting surface, minimizing bounce. stop watch digital - 2 nos scale 1 mtr 2 nos mounting wooden platform 300 mm height amc for 3 years inclusive.
Tender For purchase of instrumentation and control engineering practices (equipment) - motorized control valve trainer kit signal input:4 20 ma or 0 5 v valve characteristic:equal percentage stem movement:maximum 10 mm or 12 mm body material:cast iron trim material:ss 316 trim size: cv value:2 or 5 actuator:servo motor supply voltage:230 v ac, 50 hz connection: flanged or screwed type. digital indicator provided potentiometer provided for varying the 4 20 ma input signal, saybolt viscometer apparatus glass type: high-quality borosilicate glass tube. control type: manual energy regulator control. shape: rectangular bath with cylindrical test chamber. temperature range: ambient to 240 c oil bath temperature. humidity: up to 80% rh (non-condensing). power supply: 230 v ac, 50 hz. measuring range: 32 to 1000 sus(saybolt universal seconds). accuracy: as per astm d-88( 0.2 seconds). mounting type:benchtop. capacity:one cup(approximately 60 ml). control mode:manual operation. port size:standard orifice sizeas per astm d-88. features:oil bath with heater,thermoregulator,insulated outer body,orifice,receiver flask, control valve trainer kit three pneumatic control valves provided with individual hand valves valve characteristics: i) quick opening ii) linear iii) equal percentage. valves connected in parallel configuration for comparative study. pneumatic operation with air supply connection. control valve assembly mounted on trainer panel. power supply: 230 v ac, 50 hz., water level measurement trainer kit using capacitive type transducer tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous level measurement. sensor output: (4 20)ma and/or (0 5)v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive level measurement.