Tender For sic of submersible pump set and all allied e/m equipment for rebored tube well near h.no.-116c shahpur jat in greater kailash constituency ac-50. - supply of submersible pump set fitted with dynamically balanced ss impeller mounted on stainless steel shaft with protection sleeve having stage bowl & closed grained shorted type impeller, the pump will be directly coupled to required wet type induction motor of 7.5 hp, 10 stage, speed 2900 rpm suitable for operation of 3 phase, 415 volt, 50 hz, ac supply with efficiency 70% at following duty point:200 lpm on 90 mtr. head. having discharge outlet 50 mm and outside dia 142 mm.make: bs/skope/ any djb approved make, supply of hut type electrical feeder pillar / fabricated with 50 x 50 x 6mm angle iron and 16 swg ms sheet with horizontal and vertical intermediate member of suitable size. i.e. 1370 mm x 760mm x 460 mm. with arrangement for mounting of switchgear and electrical energy meter i.c. painting heaving following item fitted.a) mccb 63 amp, 4pole, 415volt, 35 ka -1 no.b) rccb 63 amp, 4pole with earth fault indication protecting a circuit automatically in the event of earth leakage sensitivity 100ma, - 1 noc) fully automatic star delta starter of relay range 13-21 amp. (7.5 hp to 10 hp) 3 phase oil immersed type -1 no.d) ampere 96 x 96 mm. square shape 0-30 amp-1 no.e) voltmeter 96 x 96 mm. square shape 0-500 volt-1 no.e) indicating lamp (a set of 3 lamps) 1.setf) shunt capacitor of 10 kvar mpp type with three phase isolator with suitable bankingg) motor protection assembly with earth leakage protection phase sequence corrector, singlephasing, protection, overload protection, high voltage / low voltage protection time delay power on, programmable time switch i.c. r&b phase facility to change over from automatic, to manual &vice verse for up to 10 h.p -01 nos. complete wiring & installation of above accessories with required copper conductor wire and thimble etc. 01 job.make of all components: any djb approved., s/o pvc insulated & pvc sheathed cable with plain copper conductor having 3 phases, 3 core flat for submersible motor of 4 square mm size each 100 mtrs.make:grandlay / havells./any djb approved make, s/o m.s. clamp of 600 mm length duly fabricated out of 12.5 mm thick 75 mm wide, m.s. plate for holding the pipe of 50 mm dia., s/o double flange gi column pipe 50 mm dia medium class each of 3 mtrs long duly threaded on both ends, welded fitted with gi flange on both ends with slot of submersible cable. make: tata/ jindal./any djb approved make, s/o/ tail piece of the medium class gi pipe 500 mm long with one end threaded as per outlet of pump & another end flanged as per size of gi pipe 50 mm dia., s/o gi 90 bend of size 50 mm dia having both side flange (heavy duty)., s/o nut & bolts of 1/2 dia of different size i.e. 1.5 dia& 2.5 long full threaded., s/o rubber packing for 50 mm dia flange., fabrication and supply supply of bore cover approx size 8-10 inch diameter made out from 6mm thick m.s. sheet in 2 halves & a circular hole in centre 3-1/2 dia. with locking arrangement by nuts & bolt., earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., installation of t/well by lowering of sub p/set with all allied above items. this includes installation and grouting of panel boards with all electrical wiring & cabling at site. all tools & tackles i/c. tripod chain pulley blocks etc. shall be arranged by the firm. this includes testing & commissioning of t/well on load at site i/c. cartage, loading & unloading of material. it also includes a trial run of 30 hrs operation successfully by the firm. all required civil work included in the scope of work.
Tender For supply of 1. goods, amit make hvac spare refrigerant side glass for vande bharat as per rdso specification.2. vb trainset amit make hvac spare fresh air filters for vande bharat as per rdso specification.3. vb trainset amit make hvac spare filter drier for vande bharat as per rdso specification.4. b trainset amit make hvac spare hp cut out for vande bharat as per rdso specification.5.vb trainset amit make hvac spare ohp (danfos make) for vande bharat as per rdso specification.6.good,amit make hvac spare hand shut off valve for vande bharat as per rdso specification.7. goods, amit make hvac spare brass distributor for cooling coil for vande bharat as per rdso specification.8. vb trainset amit make hvac spare transducer lp for vande bharat as per rdso specification.9. vb trainset amit make hvac spare condenser fan blade (630 dia and 8 blades) asper rdso specification.10. goods, amit make hvac spare switch on/off as per rdso specification.11. vb trainset amit make hvac spare phase sequence relay as per rdso specification.12. goods, amit make hvac spare contactor blower as per rdso specification.13. goods amit make hvac spare fresh air sensors (ntc) as per rdso specification .14. amit make hvac spare return air sensors (ntc) as per rdsospecification.15. goods, amit make hvac spare pressure transmitter (transducer) lp: 0-10 bar as per rdso specification.
Tender For supply of 3 phase power measurment trainer kit , battery charger , battery for inverter , inverter , earth leakage circuit breaker, single phase , phase sequence indicator , phase sequence indicator , portable digital ammeter , portable digital energy meter , portable digital multimeter , portable digital wattmeter single phase , portable frequency meter , portable moving iron ammeter , portable standard energy meter , three phase lamp load , rs flip flop , t flip flop , multiplexer and demultiplexer trainer kit , parallel operation of alternator , dc series motor , single phase transformer , sepratly excited dc generator , tachometer , synchronous generator , portable digital earth tester , portable digital power factor meter three phase , digital power factor meter single phase , portable digital wattmeter three phase , portable lcr meter , digital flux meter , thermistor kit , lvdt trainer kit , digital clip on meter , analog megger , portable moving iron voltmeter , portable wattmeter , thermocouple trainer kit , digital breakdown voltage testers , inverse time over current relay induction type , earth leakage relay , fuse and mcb testing kit , inverse time over current static relay , display board different wires and cable , display board - different switches , digital megger , single phase power measurment kit , dol starter , electric drill kit , soldering gun kit , motor coil winding machine , dc shunt motor- shunt generator set , dc shunt motor -series generator set , dc motor alternator set , squirrel cage induction motor , slip ring induction motor , single phase capacitor start motor , three phase transformer , variac three phase , stroboscope , synchronous motor 3 phase , kirchhoffs law verification kit , portable digital power factor meter , rlc circuit trainer kit , study of self and mutual inductance measurment trainer kit , dc regulated power supplies , trainer board to study chopper , trainer board to study dual converter , trainer board to study cycloconverter , study of mosfet trainer kit , scr based lamp intensity control , 8085 microprocessor trainer kit , micrcontroller trainer kit , model cut section of refrigerator , cut section model of air conditioner , portable digital lux meter , resistance welding machine 3 phase power measurment trainer kit : 3 phase power measurment trainer kit by using ct (100-50-20-10/5a), pt(400-220/110v) and 3 phase wattmeter, battery charger : scr based automatic 12 v, ac input voltage 230 v, output dc voltage 0-12 v, 0-2 ampere rating provided with voltmeter, ammeter of suitable range, battery for inverter : tubullar lead acid battery min 180 ah, inverter : pure sine wave inverter of rating 1500 va or more, compatible with one 12 volts battery and noiseless operations. , earth leakage circuit breaker, single phase : single phase two pole 230v, 25a, 50hz, 30ma sensitivity, earth leakage circuit breaker, single phase : three phase four pole 400/415v, 25a, 50hz, 30ma sensitivity, phase sequence indicator : phase sequence indicator suitable for 50v-500v ac from 25-55hz, phase sequence indicator : rating 30 sec,500v,burden 15 va, voltage 50-500v, portable digital ammeter : 0-10 a ac, portable digital ammeter : 0-10 a dc, portable digital energy meter : 1-phase 2 wire, 240v, 5a, portable digital multimeter : 3. 5 digit, 1000v ac & dc, 0. 1 mv ac voltage //bid details2 / 72resolution, portable digital wattmeter single phase : digital wattmeter, 4. 5 digit led display, single phase, 230v, 50 hz,0-15a, portable frequency meter : digital, 4 digit led display frequency meter suitable for use on 230 v ac main supply range 20-99 hz, portable frequency meter : vibrating reed type 230 v, having 21 reed 40-60 hz. abs body, portable frequency meter : moving coil type, portable housed in phenolic moulded body with antiparallax mirror. scale and knife edge pointer, range 40-60 hz, 230 v, portable moving iron ammeter : 0-5 ampere ac ammeters portable moving iron, 150 mm uniform scale with
Tender For tender for supply of negative sequence voltagesensing phase11 /33 kv frequency 200 hz p.no mer5590 or negative relay with sensitive broken conductor protection for 11kv & 3.3kv frequency 200hertz , digital clamp meter /tong tester 0-15-60-300 amp , flash light dia- 176 to 200 watt- 55 , type of battery smf halogen light hand held search light , fixed contact assy. cm5031 , kit kat fuse bk001075 , pin contatct main 1713401 , contactor power unit 3 pole 415/550v , 300-400 amp. ml-10 or equivalent , heavy duty glass fiber / frp highly insulated , self-supporting type ladder with platform size- 18 inch x 32 feet , 3 pole power contractor complete set , 500 amps coil voltage 415v/550v , or equivalent , 3 pole power contractor complete set , 2no + 2nc , 230 amps coil voltage 550v. ml 6 or equivalent , fixed contact 11kv h.t. switch , moving contact 11kv h.t. switch , epoxy resin cast type potential transformer for 11kv , 110volt 3 phase switch , epoxy resin cast type current transformer for 11kv switch , 300/150/5a
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi