Tender For supply of digital earth tester detailed description as per item 1 of the attached specification document , metravi hand held 100khz detailed description as per item 2 of the attached specification document , danger board named men detailed description as per item 3 of the attached specification document , danger board detailed description as per item 4 of the attached specification document , 4 digit backlit lcd hand detailed description as per item 5 of the attached specification document , hrfl 200 x series detailed description as per item 6 of the attached specification document
Tender For supply of digital backlit lcd hand true rms clamp meter,laser distance meter 100 meter range,lcd digital lux meter,digital thermo hygrometer,non contact voltage tester 1000v ac,digital lcd earth resistance meter,cutting plier 150mm size,end cutter pliers,screw driver,pvc tape 25 mm width 10 meter length
Tender For supply of drilling machine with accessories , heavy duty electric hand cutting machine with assessories , cordless impact drill driver machine , heavy duty corded electric angle grinder , heavy duty corded electric rotary hammer drill machine , screw driver set , heavy duty grip plyer set , heavy duty corded electric metal cut off saw , copper welding cable , cordless jigsaw cutting machine , professional laser distance meter measuring machine minimum measuring distance range 100mtr , corded electric wood router machine , earth tester analog type , cable insulation tester analog , ndt machine , ph and tds meter
Tender For corrigendum : supply of digital multimeter,digital earth resistance meter,digital micrometer,infrared ir thermometer,vernier calipers digital,load cell tester
Tender For corrigendum : supply of t&p material under dapoli-i subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t&p material inder lote subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t and p to khed subdivision - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t&p material under dapoli-ii subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t and p material under mandangad subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp