Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 5-11 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved en iso 20345 :2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistantoutsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance (esr) protection. 7). dielectricfootwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified)reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanizedrubber outsole good abrasion resistant for extra durability heel energy absorption design tominimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 6-11 as per attached chart) [ warranty period: 12 months after the date of delivery ]
Tender For auction sale of depot miscellaneousllaneous scrap - electrical parts & fittings scrap (comprising of ceiling fan 1200 mm and 1400 mm & spare blade with handle, invertors off sizes, battery charger, reading light, carriage fan with net & spare net, bldc fan 400 mm with net & spare net, dg exhaust fan, 2 mbps line terminal, outdoor fitting, led street light fittings, ms meter, exhauster fan, fluorescent light, earthling device, wall bracket fan, air circulating fan, emergency light fitting, solar plate, meter box, converter, switch board off size, led batten-1x18 watt, hrc fuse, carbon brush, aqua guard water, voltage stabilizer, air compressor, blower, room heater, power contractor, 9 watt tubular led lamp, night light fitting, change over switch, energy meter, control transformer- 100 & 200 volt, stand fan, fl fitting, electronic rectifier cum regulator unit, led t-8 batten, water geyser-10, 15 & 25 liters, main switch 300 ah, pcbs& led flood light-30, 70 & 200 watt fitting, compressor-5.5 tone, 1.0 tone, 1.5 tone & 2.0 tone, m.c.c.b 125 ан, 63 ah & miscellaneous electricals parts & fittings etc. qty. 13900.00 kgs.
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins
Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 6-9 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved ? en iso 20345 : 2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistant outsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance(esr) protection. 7). dielectricfootwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified)reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanizedrubber outsole good abrasion resistant for extra durability heel energy absorption design to minimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 6-10). (size and quantity details furnished in annexure). [ warranty period: 30 months after the date of delivery ]
Tender For tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For upgradation of electrical installations in gpra residential colony, sector vii, antop hill, mumbai 37. sh:- strengthening and illumination optimization of external lighting infrastructure through deployment of energy-efficient luminaire systems to eliminate low visibility zones in horticulture plant store area at phase ii, sector vii, antop hill, mumbai 37.subwork/packages:upgradation of electrical installations in gpra residential colony, sector vii, antop hill, mumbai 37. sh:- strengthening and illumination optimization of external lighting infrastructure through deployment of energy-efficient luminaire systems to eliminate low visibility zones in horticulture plant store area at phase ii, sector vii, antop hill, mumbai 37.
Tender For 1) provision of electrical vehicles (ev) chargers at divisional office/mys & gati shakti office, mys. 2) replacement of non-inverter type to energy efficient inverter based 5 star rated ac plants in service buildings over mys div.
Tender For empanelment of contractors (furniture/interior, civil & repairs, electrical) and consultants (architects, electrical consultants, civil/structural consultants, structural auditors/ electrical & energy auditors) and manufacturers and suppliers of (air-conditioning systems, sign boards) & scrap dealers