Tender For consultancy service for the 3rd party inspection, quality control, quality supervision, testing & submitting reports for the work filling mi tanks (additional 11 tanks) in aland taluka and afzalpur taluka of kalaburagi district under bori lis.
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode
Tender For consultancy work for preparing socialimpactassessment and socialimpact management report, environmental impact study and mitigation report for the proposed new housing pratapgarh
Tender For consultancy service for tpi work and quality control for the work of widening and strengthening of sadodar methan bagathara butavadar mandasan moti paneli road bet. km. 0/0 to 18/0, dist.jamnagar
Tender For supply of ball valve api 6d for c2 c3 pipeline project of gail c c-- enquiry document-mr, ball valves (api 6d), gen notes to mr, data sheet for eh ball valves (svs), data sheet for 14 inch ug ball valve -mov, data sheet for 14 inch ag mov, data sheet for 12 inch bw ag ball valve, data sheet for 12 inch mov, flg, ag ball valve, data sheet for manual 14 inch flg ag ball valve, data sheet-bw-manual-ug, data sheet manual-rb-flgd, data sheet-rb-flgd-se, data sheet-cryo-bw, data sheet-cryo-flgd, data sheet-lt service-fl, data sheet-lt service-flgd, data sheet-cryo-flgd, data sheet-utility, data sheet-lt service-rb-bw, data sheet, data sheet, specification for documentation requirement from suppliers, specification for quality management system requirements from bidders, blank format-form-b-b1-l-l1-s-s1, blank format-form-t, blank formats-form f-support foot details for ball valve, inspection and test plan for electro-hydraulic control value actuators, itp for electrical motor operated valve actuators, inspection and test plan for onshore ball valves (2, & above), specification for electrical motor operated valve actuators., standard specification for fire protection enclosure of valve actuator and accessories, standard specification for pipeline ball valves (onshore), technical notes for valves, vendor data requirements, vendor data requirement for ball valves, motor operated valve, motor operated valve, motor operated valve, motor operated valve, motor operated valve, job specification, job specification for esh actuator for sv valves, annexure-i to mr 9010
Tender For providing of integrated security surveillance system service - facility/asset protection; capture devices, recording devices, esata; high media quality, ability to archive footage, maximum security footage; buyer’s premises; mandatory access control system (mac);..
Tender For purchase of sports exercise physiology lab equipments - anaerobicergometer(upper body), suitable for anaerobic upper body test (wingate option). adjustable standard chair for optimal positioning easy to start with lighter fly wheel. the weight basket is released by a pushbutton mounted on the cover. work load range 50 watt-2400 watt. 5 khz hr system in display. should be already calibrated with correct weights weight basket (1kg) system must have 4pcs 0.1kg, 1pcs 0.5 kg, 3pcs 1kg. must include-chest belt, pc, anaerobic test software, user license, ups, power adapter, printer, hdmi cable. connectivity through rs232.international safety standards european ce/usfd approved., anaerobicergometer(lower body), an ergometer for anaerobic tests (wingate test) for lower body with unique anaerobic test software computer laptop with accessories like ups, printer of suitable configuration should be provided by the supplier. multiple bouts with fatigue index high sampling frequency (50 hz) weight basket (1 kg), the fastest way from 0 to full power start from 0 rpm with accurate power extra rigid frame calibrated with correct weights 5 khz hr system for display pc connectivity withrs232 work load range: 50-2400 w weight basket system (0.1kg 4 pc, 0.5 kg-1 pc, 1 kg- 8 pc weights) for accurate workload. extra wide floor stands, prepared for fixed installations. adjustable seat post handlebar with basket release button resistance: a) system: weight basket, b) flywheel electronic meter shows pedal turns per minute (rpm)- heart rate in beats per minute (hr)- cycling time in minutes and seconds (time)- intended cycling speed in km/ miles per hour (speed)- plus distance covered in miles (distance). international safety standards. european ce/ us fda approved., spirometer (with mip andmep testingfacility), should include validated bidirectional digital turbine flowmeter or pneumotachograph with max flow range of 16l/s should be provided with suitable software for data management, real time assessment and accurate interpretation the system should have autonomy of min 4 hours. must include rechargeable batteries, battery charger, adapters, thermal papers (if required), usb cable, user manual, single use mouthpieces (200pc), single use nosepieces (25pc), thermalprinter rolls [10pc (if required)], compatible desktop/laptop, a colored multi-function printer the compatible desktop/ laptop must meet the specifications as under windows 10 (32 bit and/or 64bit), min 2ghz cpu with ram more than 4gb, more than 500gb hdd and 4 usb ports, a fullhd display monitor, ups, keyboard, mouse the lung function tests must include fvc pre/post, svc pre/post, mvv, spo2 (optional: mip/mep) interface options: usb/ rs232/bluetooth colored display safety and quality control in compliance with international guidelines (i.e. ats, ers), handgripdynamometer, measuring range up to 100 kg minimum measuring unit: 0.1kg accuracy: 0.1kg display: lcd in 3 digits items displayed: each value and the average automatic stop approx. 1minute after the final measurement dry battery with a life of approx. 100 hrs. service, temperature range: 5 to 35 degree c, backdynamometer, measuring range up to 300 kg minimum measuring unit: 0.5kg accuracy: 0.5kg display: lcd in 4 digits displayed: each value and the average automatic stop approx.1 minute after the final measurement, dry battery and life of each cell approx.100 hrs service, temperature range: 5 to 35 degree c, sit and reach box, rust proof long lasting metal box with adjustable height will be preferred scale marked in centimeters with maximum stretching indicator slide portable, blood pressuremonitor(digital), display and measurement features- display type: lcd digital display for clear and easy reading- measurement range: typically measures blood pressure and pulse rate with accuracy. - cuff size: universal cuff size, usually fitting arm circumferences between 22-32 cm accuracy and reliability- accuracy: clinically validated for accuracy, w
Tender For providing of integrated security surveillance system service - remote video monitoring; warehouse; high media quality; buyer’s premises; mandatory access control system (mac); online application; na; na; yes
Tender For accreditation/ certification from (national accreditation board for testing & calibration laboratories) nabl-quality council of india (qci) for barsua iron mine quality control laboratory by third party agency/ service provider/ consultant.