Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For maintenance of electrical installation in non-residential building at chandigarh.(amc of 2 nos. 8 passenger lifts (orbis make) installed in new girls hostel block in post graduate govt. college for girls sector-42, chandigarh).
Tender For corrigendum : for the work of electrical line for construction of 11 kv independent feeder from 33/11 kv electrical sub-station mohammadabad tundla to release 460 kva load on village-toola post-himmatpur on semi-turnkey basis under jal jeevan mission scheme under the jurisdiction of electricity distribution division, tundla.
Tender For tender for supply of electrical items - 20/36 watt led tube fitting , non integral type , 4x1 feet length having minimum luminous efficacy of 3600 lumen/watt , 9/10 w led lamp having minimum luminous efficacy of 100 lumen/ watt , 90-95 watt led streetlight luminaire with ip 66 protection and having minimum luminous etticacy 120 lumen/watt , 40-45 watt led post top lumiaire with ip 65 protection , 12 watt recessed/ surface mounted round led light fitting , having luminous efficacy of minimum 199 lm/w , 100 watt led flood light luminaire with ip 66 protection and having minimum luminous efficacy 120 lumen/watt. , surface/recess mounted 600x600 mm led light fitting , 36 watt having/luminous efficacy , recessed/ surface mounted round led light fitting , 18 watt having luminous efficacy of minimum 100 lm/w , 450 mm sweep pvc blade wall fan (heavy duty) , 1200 mm sweep bee e star rated , ceilling fan with brush less direct current (bldc) motor , 225 mm sweep light duty metallic body exhaust fan including louvers , fancy wall bracket fitting along with 9w retrofit led lamp , 5/6 a modular switch , 15/16 a modular switch , 3 pin 5/6 amp socket outlet , 6 pin 15/16 amp socket outlet , ac starter switch 25 amp , 5/6 a , 3-modular switch socket combined box , 5/6 amp , 3-pin plug top , 15/16 amp 3-pin plug top , stepped type modular fan regulator (2m) , call bell , modular call bell pushy , iron screw 40 mmx 6 mm , pvc gitti (1.5 inch) , cable clip with metal nails (8/10/12 mm) , casing capping (25x16 mm) , 1 sq. mm frlsh copper wire , 90 metre roll , 1.5 sq. mm. frls copper wire , 90 metre roll , 2.5 sq. mm frls copper wire , 90 metre roll , 4 sq. mm. fels copper wire , 90 metre roll , 3- core 6 sq. mm btc cable , 3-core , 1.5 sq. mm unarmoured copper cable , 3-core , 2.5. sq. mm unarmoured copper cable , 3-core , 4 sq. mm unarmoured copper cable , 6 - 32 amps single pole c miniature circuit breaker , 2.5 mfd fan capacitor , 3.15 mfd fan capacitor , pvc black tape , ampere tape/ bitumen tape , 33 kv lightening arrestor gl clamps bolts and nuts with washers , 36 kv 20 ka , class - 1 , 50 hz , 33 kv pin insulator with pin washers and nuts , 33 kv drop out fuse element , 63 amp , single phase energy meter , 5-30 amp , 3- phase energy meter , 10-60 amp , 9-10 watt led mirror light fiting having luminous efficacy of minimum 100 lm/watt , heating element of 15/25 ltrs capcity water heater , brass batten holder , 15/16 a , 3- modular switch socket combined box , 2 pin male female adapter plug top , casing pin , 6 mm x 75 mm steel fastner , 40 amps dp c miniature circuit breaker , 63 amps tpn c curve , miniature circuit breaker , 20 a wire connector , 400 amps , 33 kv drop out fuse connector
Tender For corrigendum : supply of electrical fencing - single zone energizer , external hootor , ac charger controller unit , battery , lightning diverter kit , fence live light , outdoor console rack , inter mediate posts , corner and end posts , support pole , intermediate post insulators , end strain hooks , end strain insulators , joint clamps , fine pitch wire strainer , ht wire , double insulated cable , warning sign board , earthing , gate top electrification , service fence erection , service post welding , freight and insurance
Tender For providing of manpower outsourcing services - fixed remuneration - it-technical; it engineer; me mtech ms in cs it electronics mca msc in cs it electronics electrical mechanical be btech in cs it electronics electrical mechanical doeacc b or c and cisco ccna diplo..,manpower outsourcing services - fixed remuneration - admin; admin officer; post graduate,manpower outsourcing services - fixed remuneration - finance/accounts; accounting operator or accounts assistants or accounts executive; graduate,manpower outsourcing services - fixed remuneration - librarian; computer operator cum librarian; graduate with one year certificate course in computer or diploma in computer applications desirable b lib or 2 years experience in library,manpower outsourcing services - fixed remuneration - admin; administrative operator or office assistant or executive assistant; graduate,manpower outsourcing services - fixed remuneration - admin; personnel assistant; secondary school,manpower outsourcing services - fixed remuneration - it-technical
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
Tender For electrical (g) portion of work for (1)construction of rpf out-post with guard room rest room at antagarh (2) construction of rpf out-post with guard room rest room at taroki (3) construction of rpf out-post with guard room rest room at rowghat (4) gym at 07 barrack (barrack at raipur, wrs, byt, bia, bmy, durg, drz)
Tender For construction of eklavya model residential school (emrs) building with boys hostel i/c wardens residence, girls hostel i/c warden residence, kitchen & dining, staff residence 26 nos (1 no. principal residence 15 no. type- iii for teaching staff residence, 10 no. type-ii for non teaching staff residence) & 1 no. guest house i/c internal water supply and sanitary installations, electrical installations , drainage, development of site and bulk services for emrs at hezamara, dist- west tripura, state - tripura ( sh:- construction of compound wall, sub station and sentry post, ug sump, internal roads, water distribution lines (phase-1)) sub work:-preparation and supply of structural drawings,