Get complete information related to latest Spindle Rod Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Spindle Rod Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Spindle Rod Tenders.
Tender For corrigendum : supply of fixed contact assembly 400a part no bd 4510 , arc control pot separator part no ek 6050876 , barrier part no ek 6050869 , insulated bolt big part no pd 420 , insulated bolt small part no pd 8296 , carriage assembly complete 400 630a part no bd 5550 , moving contact assembly part no bd 5551 , jaw contact assembly set part no bd 4050 , auxiliary plug and socket assembly complete set part no bd 4850 , guide pin big part no pd 4043 , guide pin small part no pd 3597 , lead screw assembly part no bd 4860 , operating mechanism complete set part no bd 4911 , rod holder assembly part no bd 4921 , shunt trip coil assembly part no 1650ts , isolating spout assembly with nylon shroud part no bc 9977 , elr core balance current transformer part no ea 6650 , power pack unit 110v dc part no bd 5999 , instrument chamber box complete with internal wiring including selector switches, indication lamps voltmeter, ampere meter, fuse base etc part no bdw 7771 , partition plate assembly part no bd 5255 , operating shutter assembly part no bd 5310 , gas van pipe part no bd 5589 , ocb tank partition part no bd 4711 , earthing bar contact part no bd 8810 , cable entry box part no bd 2290 , idmt relay complete set with 2 over current and 1 earth fault with instantaneous tripping high set part no ea 6561 , high speed tripping relay part no ea 6890 , assorted hardware part no bd 9295 , under and over voltage relay part no ea 6591 , heavy duty earth leakage relay with leakage display time lag facility and cbct part no ea 6641 , trolley complete with all accessories part no bd 8268 , rotary switch complete with link and fixing plate part no bd 9191 , complete wiring set part no bd 5988
Tender For various works in sub tehsil longowal - patwari cabins:-scraping cement outer plaster, scraping cement inner plaster, cement rendering on plaster 1mm thick, 12.5 mm thick cement plaster 1:4, 20mm thick cement paster 1:4, first class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level., 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure, 12.5 mm thick cement plaster 1:5, 20mm thick cement paster 1:5, preparation of plastered or concrete surface or painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish, applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface, distempering with acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade, finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sq, providing and laying vitrified floor tiles in different sizes in light colour shades made using full body technology (thickness to be specified by the manufacturer) with water absorption s less than 0.08% and conforming to is : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) size 600x600 mm, providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%, light reflection > 85%, thermal conductivity k = 0.052 - 0.057 w/m k, fire performance as per (bs 476 pt - 6 &7)in true horizontal level suspended on interlocking t-grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized@120 gsm) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter m-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main t . the system should rest on periphery walls /partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of theengineer-in-charge.with 16 mm thick beveled tegular mineral fibre false ceiling tile (nrc 0.55 to 0.6)size 595x595 mm, earth work in excavation in foundations trenches etc. in all kinds of soil where pick-jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres., cement concrete 1:8:16 with stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type, first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth, base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mix
Tender For corrigendum : supply of t&p material under dapoli-i subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t&p material inder lote subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t and p to khed subdivision - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t&p material under dapoli-ii subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For corrigendum : supply of t and p material under mandangad subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For supply of crematorium shed and view cutter fence - pre-painted galvanized iron sheet of size 10ft x 3 ft and thickness 0.4 mm , corrugated galvanized iron sheet of size 8 ft x 3 ft and thickness 20 gauge , ms angle 40mm x 40mm x 4mm , ms square pipe 100mm x 100mm x 4mm , ms square pipe 50mm x 50mm x 4mm , ms square pipe 40mm x 40mm x 4mm , base plate 6 inch x 6 inch x 4mm , welding rod 3.15mm , ms iron cutting blade 14 inch dia , ms iron cutting blade 4 inch dia , self tapping screw 1 inch , self tapping screw 2 inch , drill adaptor 8mm pack of 5 pcs , red oxide , paint as per buyer requirement , tarpin oil , paint brush 4 inch , paint brush 3 inch , cement 50 kgs , fine river sand , graded stone or boulder aggregate of gauge not exceeding 25mm , hardcore of broken stone or boulder of gauge not exceeding 63mm including spreading and leveling as directed by site incharge , earth soil including spreading and leveling as directed by site incharge