Get complete information related to latest Spindle Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Spindle Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Spindle Spares Tenders.
Tender For corrigendum : tn-23018 supply of fire fighting equipment and spares, kstps, kota. - supply of fire-fighting equipments and spares for kstps, kota, discharge tube for dcp 5kg. fire extinguisher (18" ft. hose length) cartridge type, discharge tube for dcp 10kg. fire extinguisher (24" ft. hose length) cartridge type, hose with horn for co2 extinguisher 22.5 kg (5 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., hose with horn for co2 extinguisher 4.5 kg (1 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., discharge tube for 25 kg dcp wire braided hose (3 meter length), supply of ss304 seat valve assembly with rubber washer for 63mm hydrant valve , as base plate sheet (metallic) with base plate check nut, with neoprene rubber wash- er for spindle., supply of c.i is: 210 hand wheel for 63mm hydrant valve, supply of q.b detector 1/2" size 79deg it operates as a valve by allowing the flow of water contained in a fire qbd system when the heat sensitive element (glass bulb or fusible link) is operated., supply of ss304 63mm female outlet for 63mm hydrant valve, supply of ss304 63mm bonnet for 63mm hydrant valve, supply of ss304 63mm spindle for 63mm hydrant valve, discharge tube with nozzle for foam 9 ltr. fire extinguisher (1.5 mtr. hose length), insulated hand gloves with working voltage of 17000 volts and proof voltage 25000 volts as per is 4770, gumboot with steel toe cap moulded pvc to protect against oil acid and alkalie re- sistance confirming to is 15298, 63mm rubber washer for female outlet of hydrant valve, supply of s.s-304 63mm single headed fire hydrant valve as per is: 5290, vtype-a, isi marked. having pvc male blank cap with chain., ceramic wool fire blanket white density: 128 kg/m3, size : 610x7100 mm; thick- ness =25 mm. weight : 3130 gsm thisckness test metod : astm d 1777& weight test metod : astm d 3776 tensile strength in kgs (1 x4 ) = 10 to 16 psi, potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s, high velocity spray nozzles 80 , nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 90 nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 120 nicalchorme plated, ul listed, 3/4 bspt, hose reel with horn for co2 length : 15 mtr. hose reel made of ms having unique ball valve shut of devise with breaded hose & nozzle. drum red/ hose pipe black.drum length 15 mtr. , hose pipe length and diaas per requirement. test pressure 10 kg./cm.sq of hose pipe. control nozzle at the end is attached to control flow & direction., discharge tube with nozzle for foam 45 ltr. fire extinguisher ( 4.5 mtr. hose lenght)
Tender For corrigendum : swas - primary racks(with ibr certified isolation valves and ibr certified ss316h cooler coils)(isolation valve shall be with the plug & spindle should be single piece & of non-rotating type. the plug should be guided throughout its travel), wet panel - open type with canopy, dry panel, chiller unit - 2x100% redundant - min. 5 tr rating (with 25% extra capacity), conductivity(specific, cation) analyser - single channel, conductivity(specific) analyser for hotwell - single channel, ph transmitter- single channel, ph sensors, dissolved oxygen analyser transmitter- single channel, dissolved oxygen analyser sensor with electrolyte filling solution, sodium analyser (multi channel- 6 channel including spare channel), silica analyser (multi channel- 6 channel including spare channel), hydrazine analyser - single channel, degassed cation conductivity analyser, orp analyser transmitter - single channel, orp analyser sensor, free residual chlorine analyser - single channel, chloride analyser- single channel, loose supply items as per annexure-a, mandatory spares as per annexure- b, commissioning spares- reagents /calibrators/standard solutions as required for commissioning & handing over of system to owner, erection supervision and commissioning of swas at each 800 mw unit, price for one line of high pressure & high temp. - primary & secondary cooling to be considered along with other instruments as per p&id applicable for the project. (optional item for ordering), price for one line of low pressure & low temp. - secondary cooling to be considered along with other instruments as per p&id applicable for the project. (optional item for ordering), freight charges for complete scope of supply for each 800 mw unit upto respective project site
Tender For corrigendum : supply of refilling of oxygen gas in ntpc cylinders and replacement of cylinder spares at ntpc gadarwara - m1060101007-gas chem oxygen 99.9 percentage is309 , hydraulic testing 47 ltrs cap cylinder , replacement of valve , replacement of valve safety guard cylind , replacement of spindle , replacement of gland nut , replacement of cylinder ring , painting of cylinders , de- greasing charges