Tender For corrigendum : supply of breakers - 11 kv ct swbd. incomer-breaker retrofit , 11 kv ct swbd. motor feeder retrofit , 11 kv ct swbd. trafo. feeder retrofit , 11 kv ct swbd. seht feeder retrofit , 11 kv ct swbd. bus-pt panel retrofit , installation testing commissioning of switchgear components for refurbishment of abb make 11 kv switchbaord at coastal terminal ht substation including retrofitting of existing sf6 circuit breakers with new vacuum circuit breakers vcbs panel control wiring modifications for numerical relay retrofit and conversion to 110 vdc auxiliary supply as per tender specifications scope of works and directions of engineerincharge
Tender For supply of removal of eccentricity of 4kw 6kw 0.4 kv vibrating feeder motor , re shafting of the rotor of 4kw 6kw, 0.4kv vibrating feeder motor , repairing of the body of 4kw 6kw vf motor , re conditioning of unbalanced weight of 4kw 6kw, 0.4 kv vf motor , re developing of motor foundation gutka of of motor upto 138 kw , preparation of mistreated enlarged bolt hole thread of vf, unbalance weigh or any other motor. , redevloping of motor housing of vf motor 4kw 6kw vibrating feeder motor , redevloping of motor housing of upto 30kw, 0.4kv motor , redevloping of motor housing of 37 to 60kw ,0.4kv motor , redevloping of motor housing of 75 to 125kw ,0.4kv motor , re conditioning of rotor bearing seat of upto 30kw, 0.4kv motor , re conditioning of rotor bearing seat of 37kw to 60 kw 0.4kv motor , re conditioning of rotor bearing seat of 75to 125kw, 0.4kv motor , repairing of bearing seat of rotor shaft of 525kw, 6.6kv coal crusher motors of chp , removal of shaft eccentricity and making bearing portion as per size of bearing 55.1 kw to 75 kw , removal of shaft eccentricity and making bearing portion as per size of bearing 75.1 kw to 90 kw , removal of shaft eccentricity and making bearing portion as per size of bearing 90.1 kw to 200 kw , repairing of broken stator housing collar of motors 75.1 kw to 90 kw , repairing of broken stator housing collar of motors 90.1 kw to 120 kw , repairing of bearing point outer race on bearing housing of 0.4 kv, 6 kw vf motors , repairing of bearing point outer race on bearing housing of 0.4 kv, 138kw motors , repairing of motor coupling of wt and other motor coupling , repairing of lead screw tie rod of conveyors of a chp of chdiii ) /bid number : gem/2026/b/7495635 * /dated: 05-05-2026 & & / bid document 1 / 17
Tender For corrigendum : supply of lt circuit breaker at vindhyachal and allahabad substation e e - supply of 415v 3400a 75 ka 3-pole ac lt air circuit breaker and accessories for retrofitment as per attached ts and sow , retrofitment kit with copper bus thickness 8mm width 10cm for supplied acb , retrofitment of new lt air circuit breaker in acdb including dismantling of old circuit breaker , springchargingmotor , aux. contact sets , bus bar seal off insulators , arc-chutes , moving contacts , arcing contacts fixed moving , springs closing opening , closing coil with resistor , tripping coil with resistor , supply of 415v 1000a 3-pole ac lt air circuit breaker and accessories for retrofitment as per attached ts and scope of work , supply of 415v 800a 3-pole ac lt air circuit breaker and accessories for retrofitment as per attached ts and scope of work
Tender For corrigendum : supply of operation and maintenance of electrical and mechanical installations , job contract for operation and day to day maintenance services of airport systems equipments , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , supply of convertor or driver suitable for philips make 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for osram make 120w types led luminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted fitting , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of reflector suitable for ama make papi , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer
Tender For corrigendum : supply for 9040m26c19 procurement and commissioning of d044 extension section and carrying out -incomer from transformer, line pt , bus coupler , bus pt , outgoing transformer feeder , outgoing plant feeders , outgoing motor feeder