Get complete information related to latest Staining Jar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Staining Jar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Staining Jar Tenders.
Tender For corrigendum : supply of reagents for immunoassay siemens atellica im1600 analyzer e e -alpha fetoprotein , atpo ii , ca 125 , ca 19.9 , cea , cortisol , estradiol , ferritin , fol , psa free , fsh , ft3 , ft4 , homocysteine , pth , insulin , lh , prolactin , psa , total hcg , tsh3-ultra ii , testosterone ii , vitamin b12 , vitamin d 25-oh , troponin i high sensitivity , ntpbnp , procalcitonin- brahms , amh , pct-brahms qc kit , psa free cal 2pk , pth qc kit , t3 t4 vb12 anc rgt 6pk , thcg dil 2pk , vb12 dtt rel kit , vitd qc kit , wash 1 , atpoii dil 2pk , atpo2 qc kit , cuvettes , sample tips , apw1 2pk , acid , atellica im apw3 2pk , base , ca 125ii cal 2pk , ca 19_19 dil , cal 30 2pk , cal a2pk , cal b 2pk , cal c 2pk , cal d 2pk , cal e 2pk , cal q 2pk , cea dil 2pk , cleaner , hcy cal 2pk , hcy dil 2pk , fol dtt rel kit , insulin cal 2pk , insulin dil 2pk , multi diluent 1 2pk , multi diluent 11 2pk , multi diluent 13 2pk , multi diluent 2 2pk , multi diluent 3 2pk , atellica im multi - diluent 15 , tube top sample cups , sato t102h size 90 mm widthx100 m , amh qc , humidity pack , sp probe assay reagent
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref