Tender For providing and installing open gym equipments with buy back of old gym equipments at district park at dilshad garden (link chain) (specialized work). - schedule -a , air walker: providing, designing and fixing of air-walker of size 1100x550x 1480 mm fabricated with main post of 114 mm dia and 2.5 mm thick and other pipes of 40 mm dia 2.5 mm thic made up of hot rolled tubular steel and hot dipped galvanized and powder coated 80-120 micron thick using akzo nobel or equivalent in desired shade and colour. all welding joints of pipe shall be robotic welded with joints scalloped as necessary and dressed off removing sharp edges and burns. zinc primer paint to be applied at all the welding points prior to finishing. all open ends of pie to be closed with gi /lldpe caps, base plate cover shall be made of virgin lldpe plastic by rotational molding with minimum 8 mm thickness, uv resistant and colour as approved by engineer-in-charge. high quality grip rubber should be sued on handles. foot hold shall be made of nylon alloy with rounded edges to prevent impact and injury. maintenance free bearings should be used in the equipments manufactured by reputed company duly oil sealed and self lubricated to be approved by engineer-in-charge. the equipment shall be fitted with in built limiters. the equipment shall be fixed on ground with concrete of minimum strength m-25 and j shaped welded bolts and when concrete is set, fixing the equipment on to it and cover nuts and bolts with base plate cover, all complete as per directions and approval of engineer-in-charge regarding material, shape of equipment, colour on metal, seat and pedal and fixing of equipment etc. ., sit up station: providing, designing and fixing of double sit-up station of size 1500x1150x650mm fabricated with main post of 114mm dia and 2.5 mm thick and rest of the pipe of 40 mm dia and 2.5 thick all pipes made up of hot rolled tubular steel and hot dipped galvanized and powder coated using akzo nobel or equivalent of 80-120 micron thick. all joints of pipe are robotic welded with joints scalloped as necessary and dressed off removing sharp edges and burns. zinc primer paint to be applied at all welding points prior to finishing. seat and base plate cover to be made up from virgin lldpe manufactured by rotational molding with minimum thickness of plastic as 8 mm, colorful and uv resistant and environmental friendly. the equipment to be fixed on ground with concrete of minimum strength m-25 and j shape welded bolts and once the concrete is set fix the equipments on to it and cover nuts and bolts with the base plate. all complete as per direction and approval of engineer-in-charge regarding material, shape of equipment, colour on metal seat and base pedal and fixing of equipments etc. ., air swing: providing, designing and fixing of air swing in pair of size 1150x900x1250 mm fabricated with main post of 114 mm dia and 2.5 mm thick and rest of the pipe 40 mm dia and 2.5 mm thick all pipes made up of hot rolled tubular steel and hot dipped galvanized and powder coated using akzo nobel or equivalent of 80-120 micron thick. all joints of pipe are robotic welded with joints scalloped as necessary and dressed off removing sharp edges and burns. zinc primer paint to be applied at all welding points prior to finishing. pedals shall be made of nylon alloy with rounded edges to prevent any impact of injury and base plate cover to be made from virgin lldpe manufactured by rotational moulding with minimum thickness of plastic of 8 mm, colorful and uv resistant and environment friendly. bearing used shall be maintenance free, duly oil sealed and self lubricated made by reputed company to be approved by engineer-in-charge. equipment to be fitted with inbuilt limiters to prevent unwanted movements. all open ends of pipe to be closed by gi/lldpe caps for user safety. the equipment to be fixed on ground with concrete of minimum strength m-25 and j shape welded bolts and once the concrets is set, f
Tender For corrigendum : strengthening of (e/m) equipments of various tube wells installed at babu park kotla area under kasturba nagar constituency ac-42 . - s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.make: - tata/jindal, supply of out door type 7.5 to 10hp hut type electrical feeder pillar/metal board of welded construction of size 1370mm x 760mm x 460mmfabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size onsuitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, vermin proof having following items.1. mccb 63 amp, 4 pole-1 no2. rccb/elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no4. digital ampere meter 96mmx96mm square shape of 0-30 amp range 1no5. digital voltmeter of 96mm x 96 mm square shape of 0-500 volt range with selector switch 1no6. led indicating lamps with fitting (a set of 3 lamps) 1set7. shunt capacitor of 5 kvar with three phase isolator 1no8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection. 1no9. programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p.1no10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc.as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame.make:-all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved.djb item code 10.2.1, supply of pvc insulated pvc sheathed copper conductor flat cable size 3 core x 4sq mm,1100 volts, confirming to is 694(each roll 100mtr long) make: finolex / havells./kei/any djb approved make., s/o nut bolts,washer dia 1 long full threaded, s/o rubber packing 50 mm dia. flange., lowering and lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material (rubber packing and nuts bolts) will be arranged by the firm as per site requirement. the other material required during execution will be provided by department.
Tender For supply of tube light 36w with complete fittings , led panel ceiling light warm , mcb 32 amp dp with distr box , switch socket combination 5 amp with gang box , switch socket combination 15 amp with gang box , switch piano type 5 amp , socket 5 amp , pvc ceiling rose , pvc square box 4 inchx4 inch , cable u clip with steel nails , insulation tape , mcb 100 amp 4 pole , ceiling fan 1200 mm sweep with fan hooks and fan regulator , pvc copper cable 1 sqmm single core , pvc copper cable 1 pt 5 sqmm single core , pvc copper cable 2 pt 5 sqmm single core , casing capping 25mm 2 mtr long , pvc switch board 10 way , avr for 30 kva genr set of kirloskar , bty 12v 180ah , pvc flexible pipe 25 mm , pvc pipe 110 mm 20 ft long , non skid tiles 600 x 600 mm , white cement , ridge sheet 10ft long and 450 mm wide , ppgi sheet 12ftx3ft , ppgi sheet 16ftx3ft , pbs roll 10 mtrs long each , luke for pbs roll , door hinges 100 mm isi marked , chain link roll , laip made of angle iron 50x50x6mm , binding wire isi marked , nails 1inch isi marked , rhs pipe of size 50x50x4mm , rhs of size 66x33x2 pt 9 mm of 6 mtrs long , iron patti 32mm width with 2 mm thick isi marked , gi jali net type of size 3 feet height x 9 feet length 27 sqft isi marked , gi jali net type of size 4 feet height x 21 feet length 84sqft isi marked , sds screw 1 inch isi marked , sds screw 2 inch isi marked , black screw 1 pt 5 inch isi marked , black screw 1 inch isi marked , welding rod 3 pt 15 mm isi marked , al drop isi marked , paint dark brown , paint green , paint golden yellow , paint black , paint red oxide , thinner , paint brush 50 mm , paint brush 100 mm , white distember , iron cutting wheel 4 inch , iron cutting wheel 5 inch , iron cutting wheel 14 inch , cement concrete solid bricks , cement of 43 grade opc in sealed bags , river sand , aggregate 20mm , hardcore 40 to 63 mm ) /bid number: gem/2025/b/6980620 * /dated: 09-12-2025 & & / bid document1 / 42
Tender For renovation of weather proof shed for cmfri at vizhinjam, trivandrum sh: covering of open space between roof and parapet with ms frame work and gi sheet and gi chain link fencingsubwork/packages:covering of open space between roof and parapet with ms frame work and gi sheet and gi chain link fencing
Tender For improvement of e/m equipment of various tube wells in c and d block okhla vihar in okhla constituency ac-54. - s/o pvc insulated pvc sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (each roll of 100 mtrs.). make: -grandlay/havells/gloster/djb approved, s/o rubber packing 50 mm dia. flange., providing & fixing of indicating lamps ryb along with complete wiring of above electrical equipment and with suitable size copper conductor wire ( 6 sq mm,4 sq mm,2,5 sq mm & 1.5 sq mm) and suitable size ferrule /socket of required size insulating board i/c replacement of old and damaged component s with above mentioned material .job i/c testing & commissioning of complete panel board on load as per site requirement., s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.djb sor 2024-25 item code 45.1.93. make: - tata/jindal, s/o ms nut bolts off size as per requirement., lowering & lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t & p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material will be arranged by the firm as per site requirement. beyond the depth of 250 feet.djb sor(e&m)-2022 item code 27.1.2
Tender For enhancing the water supply by replacement of damaged e/m items of various tube wells installed vilaspur camp and mohan baba nagar under badarpur constituency ac-53. - s/o motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection, time delay power on programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa up to 10 hp. make: gain guard/skope/any reputed make., supply of mccb 63 amp, 4 pole, breaking capacity at 415 v: 35-36 ka, adjustable thermal setting (70- 100%) and fixed magnetic settings. make: - l&t/c&s/djb approved., providing & fixing of indicating lamps ryb along with complete wiring of above electrical components and with suitable size copper conductor wire (6sq mm, 4 sqmm , 2.5 sq mm & 1.5 sq mm) and suitable size ferrule/socket of required size insulating board i/c replacement of old and damaged components with above mentioned materials. job i/c testing & commissioning of complete panel board on load as per site requirement., s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable. make: - tata/jindal, s/o pvc insulated pvc sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (each roll of 100 mtrs.) make: - grandlay/havells/gloster/djb approved, s/o ms nut bolts off size as per requirement., s/o rubber packing 50 mm dia. flange., lowering & lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material will be arranged by the firm as per site requirement. the other material required during execution will be provided by department.
Tender For renovation of e/m equipments of various tube wells at m-block gk-ii area under greater kailash constituency ac-50. - s/o pvc insulated pvc sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (each roll of 100 mtrs.). make: -grandlay/havells/gloster/djb approved, s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.djb sor 2024-25 item code 45.1.93. make: - tata/jindal, providing & fixing of indicating lamps ryb along with complete wiring of above electrical equipment and with suitable size copper conductor wire ( 6 sq mm,4 sq mm,2,5 sq mm & 1.5 sq mm) and suitable size ferrule /socket of required size insulating board i/c replacement of old and damaged component s with above mentioned material .job i/c testing & commissioning of complete panel board on load as per site requirement., supply of mccb 63 amp,4 pole breaking capacity at 415 volt35-36 ka adjustable thermal setting(70-100%) and fixed magnetic setting. make:- l&t/c&s/ djb approved., s/o ms nut bolts off size as per requirement., s/o rubber packing 50 mm dia. flange., lowering & lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t & p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material (rubber packing and nuts bolts) will be arranged by the firm as per site requirement. beyond the depth of 250 feet.
Tender For augmentation of water supply by improvement of e/m equipments of various tube wells at neel giri apartment area under greater kailash constituency ac-50. - s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.djb sor 2024-25 item code 45.1.93 make: - tata/jindal, s/o pvc insulated pvc sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (each roll of 100 mtrs.) make: - grandlay/havells/gloster/djb approved, providing & fixing of indicating lamps ryb along with complete wiring of above electrical equipment and with suitable size copper conductor wire ( 6 sq mm,4 sq mm,2,5 sq mm & 1.5 sq mm) and suitable size ferrule /socket of required size insulating board i/c replacement of old and damaged component s with above mentioned material .job i/c testing & commissioning of complete panel board on load as per site requirement., providing and fixing of motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection, time delay power on programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa up to 10hp. make: gain guard/skope., s/o ms nut bolts off size as per requirement., s/o rubber packing 50 mm dia. flange., lowering & lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t & p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material will be arranged by the firm as per site requirement. beyond the depth of 250 feet.
Tender For augmentation of water supply by improvement of e/m equipments of various tube wells in jj colony khanpur under ambedkar nagar constituency ac-48. - supply of mccb 63 amp, 4 pole, breaking capacity at 415 v: 35-36 ka, adjustable thermal setting (70- 100%) and fixed magnetic settings. make: - l&t/c&s/djb approved., s/o motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection, time delay power on programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa up to 10 hp. make: gain guard/skope/any reputed make., providing & fixing of indicating lamps ryb along with complete wiring of above electrical components and with suitable size copper conductor wire (6sq mm, 4 sqmm , 2.5 sq mm & 1.5 sq mm) and suitable size ferrule/socket of required size insulating board i/c replacement of old and damaged components with above mentioned materials. job i/c testing & commissioning of complete panel board on load as per site requirement., s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable. make: - tata/jindal, s/o pvc insulated pvc sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (each roll of 100 mtrs.) make: - grandlay/havells/gloster/djb approved, s/o ms nut bolts off size as per requirement., s/o rubber packing 50 mm dia. flange., lowering & lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material will be arranged by the firm as per site requirement. the other material required during execution will be provided by department.