Get complete information related to latest Stater Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Stater Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Stater Switch Tenders.
Tender For tender for the supply of equipments of solar technician (electrical) trades for govt. industrial training institutes of madhya pradesh - name of the equipment, ammeter mc 0 - 1a, ammeter mc centre zero 0-20a, ammeter mc centre zero 0-50a, anemometer for wind speed measurement, array junction box, battery cable , cable solar (black)- 5 square mm (1 meter), cable solar (red)- 5 square mm (1 mtr), clinometer: for angle measurement, cut model of lead acid battery, dc led lamp 10 w for polarity, dc led lamp 3 w protection for polarity, dc led lamp 5 w for polarity, dc pump 24 v, dc table fan- 12 v, 6 inch, 3/4 blades of isi, demonstration kit for wind generation (wind turbine with blower/fan), electrical loads:, electrical wiring and switch gear control panel/rack , halogen lamp with stand for illumination of solar panels in lab, hydrometer for lead acid batteries to check specific gravity, iv curve tester, lead acid battery 12v, 100 ah, lead acid battery 12v, 40ah, 75ah, led lights 12 v dc, led lights 6 v dc, magnetic compass, mc 4 connector (without pins), megger analog 500 v, mppt- (maximum power point tracking) - (charge controller), photo voltaic panel assembly, pins-5 mm for mc 4 connector, protective relays and contactors -, pwm (pulse width modulation) charge controller training system, pyranometer, pyrheliometer, rechargeable battery 12 v, 100 ah, rechargeable battery 12 v, 7 ah, rechargeable battery 6 v, 5 ah, resin cored solder -100 gm, solar cell based sunshine radiation meter, solar cell kit, solar charge controller with dusk to dawn automatic switching 12v, 10amp, solar charge controller with manual switch (day lighting)12v,10a, solar dc pump -1 hp, 24v, speed- 2800-3000 rpm, solar energy trainer with grouping of solar cells-, solar grid tied inverter demonstrator kit- (on grid solar power generation and training system), solar insulation meter, solar lantern (led type), solar lantern assembly sets solar lantern (led type), solar panels, solar pcu, solar photo voltaic module 75w, solar simulator for solar cell characteristic study, solar street light, solar tracker demonstrator kit (automatic), solar traffic light system, solar, wind and hybrid power plant (1 kw)., solder wax- 100 gm, spirit level 12 inch, sun path finder, sun shine recorder, volt meter 0 - 30v, volt meter 0 - 100v, waste /used water treatment by electro coagulation, weather monitoring system, wire three core (230 v, 15 a)
Tender For laying of tower foundations, erection of towers, stringing sagging of conductor for lilo of 220 kv line from malout to abohar at proposed 220 kv switching station bahawal bassi. 220 kv line from 220 kv switching station bahawal bassi to rts
Tender For enquiry for procurement of different rating fast switching semiconductor fuse installed at various locations at 2x660 mw, sstpp, mppgcl, dongalia.
Tender For bid to ras custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if requir
Tender For corrigendum : engineering, procurement, construction (epc) for supply, erection, testing & commissioning of 2x25 kv 50hz traction overhead equipment, traction sub station, switching stations and scada for railway electrification of double line and other associated modification works of the existing ohe of single line and yards in connection with doubling between ankai station (excl) at 16.00 km and karanj gaon (excl) at 69.01 km (i.e., 53.01 km) on nanded division of south-central railway in maharashtra state, india.
Tender For annual contract for switching on and off road lights daily and their maintenance in atru municipal area (including 1 lightman and 3 helpers) - ????????? ??????? ???? ??? ??? ???? ???????? ???? ???? ? ???? ???? ??? ??-???? ???? ??????? ??????? (1??????? ? 3 ?????? ????) ?????
Tender For supply of dome pandal water proof , tent 15x15 double layer , kanat 15x6 , dari 10x8 , chairs moulded , table , table cover , curtains 15x10 , water drum with iron cover , new cooler , paderal fan , plywood bed 6x3.5 ft , generator , helozen light , tublight , cfl 24 watt , metal light 150watt , wooden thakhat , bedding set with pillow , stablizer , mike set , carpet matting plastic coated , barrier , switching electric board , parking area , loan area , big hall , ac room , jumboo cooler