Get complete information related to latest Steering Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Steering Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Steering Cable Tenders.
Tender For repair and construction of rcc column and boundary wall covered with concertina wire at pt and parade ground under the metro line and providing concertina wire/wire mess, view cutter of fiber/acrylic sheet at dpa/dwarka sec.-09, delhi.
Tender For supply of boq mt oem - brg frt wheel , mtg eng front , spring assy front , tie rod steering , cable assy clutch , shoe set rear brake , cover timing belt outside , gasket cyl head
Tender For corrigendum : tn-23018 supply of fire fighting equipment and spares, kstps, kota. - supply of fire-fighting equipments and spares for kstps, kota, discharge tube for dcp 5kg. fire extinguisher (18" ft. hose length) cartridge type, discharge tube for dcp 10kg. fire extinguisher (24" ft. hose length) cartridge type, hose with horn for co2 extinguisher 22.5 kg (5 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., hose with horn for co2 extinguisher 4.5 kg (1 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., discharge tube for 25 kg dcp wire braided hose (3 meter length), supply of ss304 seat valve assembly with rubber washer for 63mm hydrant valve , as base plate sheet (metallic) with base plate check nut, with neoprene rubber wash- er for spindle., supply of c.i is: 210 hand wheel for 63mm hydrant valve, supply of q.b detector 1/2" size 79deg it operates as a valve by allowing the flow of water contained in a fire qbd system when the heat sensitive element (glass bulb or fusible link) is operated., supply of ss304 63mm female outlet for 63mm hydrant valve, supply of ss304 63mm bonnet for 63mm hydrant valve, supply of ss304 63mm spindle for 63mm hydrant valve, discharge tube with nozzle for foam 9 ltr. fire extinguisher (1.5 mtr. hose length), insulated hand gloves with working voltage of 17000 volts and proof voltage 25000 volts as per is 4770, gumboot with steel toe cap moulded pvc to protect against oil acid and alkalie re- sistance confirming to is 15298, 63mm rubber washer for female outlet of hydrant valve, supply of s.s-304 63mm single headed fire hydrant valve as per is: 5290, vtype-a, isi marked. having pvc male blank cap with chain., ceramic wool fire blanket white density: 128 kg/m3, size : 610x7100 mm; thick- ness =25 mm. weight : 3130 gsm thisckness test metod : astm d 1777& weight test metod : astm d 3776 tensile strength in kgs (1 x4 ) = 10 to 16 psi, potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s, high velocity spray nozzles 80 , nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 90 nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 120 nicalchorme plated, ul listed, 3/4 bspt, hose reel with horn for co2 length : 15 mtr. hose reel made of ms having unique ball valve shut of devise with breaded hose & nozzle. drum red/ hose pipe black.drum length 15 mtr. , hose pipe length and diaas per requirement. test pressure 10 kg./cm.sq of hose pipe. control nozzle at the end is attached to control flow & direction., discharge tube with nozzle for foam 45 ltr. fire extinguisher ( 4.5 mtr. hose lenght)
Tender For raising of 10 ha. plantation including barbed wire fencing, maintenance of pbs, raising of pbs at sy.no. 127, 24 of bilalukoppa (bilalukoppa-saluru block-i sec-4 area) in n.r.pura range during 2025-26
Tender For corrigendum : tender for supply of black screw 1 inch , black screw 1 5 inch , bty 1 5v aaa non rechargeable , bty 1 5v no 03 , bty 1 5v no 06 , bty 12 v 3 5 ah for lrf , bty 12 v for door bell , china clip 5 mm , china clip 10 mm , self drilling screw 1 inch , self drilling screw 1 1 2 inch , self drilling screw 2 inch , hose clamp 1 2 inch , hose clamp 1 inch , hose clamp 1 5 inch , hose clamp 2 inch , charcoal for lighting conductor , rock salt for lighting conductor , w 40 rust cleaner , alum , pvc solution 100 ml bottle , taflon tape , tds battery , magnetic bit for sd screw 8mm and 10 mm , 12 inch metal cutting disc , 4 inch metal cutting disc , 1 inch sd screw , 2 inch sd screw , 4 inch sd screw , paint brush 1 inch , paint brush 2 inch , paint brush 4 inch , waste pipe for wash basin , leakage repair patch tape , nails 1 inch , nails 2 inch , nails 4 inch , china clip 5 mm , china clip 10 mm , emery paper water proof 350 grade , abb cloth fine a veh sec , abb cloth rough a veh sec , 14 inch iron cutting wheel , grinding wheel 4 inch , wire brush wheel 4 inch for fitting at grinding machine , cutter blade 4 inch , jointing sheet , fiber rod a veh sec , fevi quick 100ml , m seal liq type a veh sec , m seal thick a veh sec 100 gm , synthetic rubber adheshive dendrite sr 998 , insulation tape small a veh sec , thread tape , loom tape , thread bandal , sr solution , sr 998 fevicol 01 ltr bottle a veh sec , pop rivets 1 inch , pop rivets 1 1 2 inch , air pipe jointer 14mm , paint blue , paint brush writing , chalk piece for welder marking , puncture repair patch , puncture repair solution , solvent rust , o ring kit , hexa blade both side , bty terminal positive , bty terminal negative , troggle switch , push button , 6v 5ah rechargeable bty , duracell 1 5 v bty aa , 9 v bty , isopropyl alcohol for pcb cleaning 100ml , soldering flux , soldering wire , 1n4007 diode 1000v 1a , 1n5408 diode 1000v 3a , 2pin spst switch 3a 250v , toggle switch spdt 3a 250v , capacitor 2200 micro farad 25volt , capacitor 470 micro farad 25volt , capacitor 1000 micro farad 16volt , capacitor 1000 micro farad 25volt , sleeves , desoldering pump , tweezers set 6 pieces , dry bty cell 1 5v no3 type c , desoldering wire , resistor 10 ohm , resistor 1 k ohm , resistor 10 k ohm
Tender For supply of mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , cat 6 cable for indoor use (q2) , hdmi cable (q3) , cat 6 patch cord (q2) , power contactors as per is 13947 - 4 - 1 (q3) , enamelled round copper wire as per is 13730 (part 0 / sec 1) (q3) , earth leakage circuit breaker (elcb) (q3) , voltage regulator for domestic fans (q3) , mild steel wire for general engineering purpose as per is 280 (q2) , wire nails (q4) , wood screws (q3) , fixed capacitors (fixed capacitor for single phase ac electric fan) as per is 1709:1984 (q3) , pvc insulated unsheathed cable with flexible conductor as per is 694 (q2) , electrical connection lugs or thimbles (q3) , ht tape (q3) , emergency push button switch (q3)
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene