Web Analytics Made Easy - StatCounter

Sterilizer Coil Tenders

Get complete information related to latest Sterilizer Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sterilizer Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sterilizer Coil Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45481783 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For corrigendum : procurement of ht schneider switchgears spares for ntpc kahalgaon - plug,sjmhu20pinplugruss,schneider,vcb, micro switch assy,mvu39s0023100sa,vcb, switch lever,msp39s3018000pl,schneider, release lever,mny39s3015000na,schneider, pb-red assy,spr39sass0001fn,schneider, pb-green assy,spr39sass0002fn,schneider, on/off indicatr assy,spr39sass0003fn,vcb, indicator assy,spr39sass0004fn,schneider, trip coil,schneider,vcb,hwx, closing coil,schneider,vcb,hwx, closing buffer,schneider,vcb,hwx, opening buffer,mvij00098-01,schneider, auxiliary switch,schneider,vcb,hwx, sprg charging motor,schneider,vcb,hwx

CTN :45657810 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For supply of primary and secondary switch board spares - red seal , nsx630-auxiliary contact , white indicator light , amber indicator light , red indicator light , module 2 current input 2 or 4 connector -20ma 420ma 15 bits , interface module1m151-1 , fus 1a type ha22 , fus 2 , 5a type ha22 , trip circuit supervision card , dc circuit breaker da402 without cradle-db1 db2 , ac circuit breaker nsx250 without socle , push button red 10 1f , head pbd22 black , nsx630-mn coil , nsx250 electrial command , fus 0.31a 6.3x32 ha37 , meter phase 72x72 250 cl1.5 cph t3fe - 0.5 cap 0.2 ind , wattmeter 72x72 250 cl1.5 bdm t3fe - 0 100kw , mccb 250a with str 22se 2 nos aux contacts , 2p mcb20ac curve

CTN :45647762 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For supply of spare for generator transformer & cooling water system - winding temeperature transmitter, dual output: 4-20ma, 90-260v ac/dc, precimeasure , current converter unit ccu18, input-pt100 rtd, output: 4-20ma dc,90-260v ac/dc , digital winding temp. remote indicator, range-0-150°c, model no. 2245.t2, precimeasure , digital oil temp. indicator remote, range-o-150°c, model no. 2245.t2, precimeasure , mcb breaker 4 poles, 10a, 10ka, c-curve, 415v ac, siemens , mcb, 6a, 2 pole, 10ka, c-curve, 240vac, siemens , mcb, 16a, 2 pole, 10ka, c-curve, 2 40vac, siemens , mcb, 2a, 1p, 10ka, c-curve, 240v ac, siemens , mcb 10a, 1p, 10ka, c-curve, 240v ac, siemens , mcb, 6a, 2pole, 10ka, c-curve, 110v, ac, siemens , moulded case ckt breaker (mccb) 32a, 55ka, 4pole, 415v ac, siemens , power contactor, 4 poles, 415vac, 12a, 415v with add on 2no+2nc (aux. supply 110v ac)3tf31-10-0a , aux. contactor (ac supervision), 110v ac, 2no +2nc,3th30-22-0a , aux. contactor, 110v ac, 3no+1nc with add-on aux. contact block 2no+1nc,3th30-31-0a , motor thermal overload relay (4-6.3a),3ua50 001g , relay used in the cooler control circuit (minilec) minilec d1hls1 , time delay relay, 110v, 0.1-10h with 2 c/o contact, micon 2a5dt5 , selector switch 2 way with off, 6a, 240v 2 pole, type: s10-61025-bb, make: l&t/kaycee , selector switch, 10a, 440v, 2 ways with off 4 pole, make: l&t/kaycee , selector switch, 2way on off,10a, 440v, 10 pole , auxiliary transformer, 415v/55-0-55 (110v), 500va, make: l&t/kaycee , led (red, green) for pump on indicator suitable, 110v ac , differential pressure gauge (fiebig) 0-1.5 kg/cm 2 above to 380v 30w 50va , water leakage detector sapcon probe length 68mm , resistance temp. detector (rtd) for (wti and oti), pt 100, precimenasure , pump main & stan - by selector switch, , nylonwasher size 2.5tkx4 id x8 od , generator , carbon brush (50.8x38.1x25.4) mm, hm6 grd , brush holder , slip ring assembly (refer annexure-10) , insulation stud with epoxy with fire , retardant, shaft l= 315 from flange face, ø55, flange l 150, width 90, flange thickness 20, hole ø18, hole spacing(l) 108, hole spacing (w) 46 measurements in mm , duplex rtd pt/100 l-930, b-630, h 370 (mm) , dail type thermometer (dtt)l=35 m,.length of bulb--100mm, bulb coneection-standard p.f. 3/4 double union. 5 kg/cm2, type-gas filled, dial siz- 150 mm or 160 mm. accuracy+-2-degree celcus. (refer annexure-1) , thermostat for (guide bearing) , max operating voltage: 220v dc (±10%) , temperature range: 20°c to 100°c , max working temperature: 110°c , capillary tube length: 6 meters , switch action: 1 spdt for alarm and 1 for trip , (at two different temperatures) , differential temperature: 2°c to 5°c , accuracy: ±3°c of set point , repeatability: ±3°c , working temperature: 110°c ((refer annexure-2) , thermostat for lower guide bearing, (spec same as sl, 35) , thermostat for space heater (maximum current capacity: 1 amaximum operating , voltage: 250 vdc ±10%temperature range: 25°c to 90°ccapillary tube length (l): 5 meters switch action: spdtdifferential temperature: 3°c to 5°caccuracy: ±3°c of set pointsetting temperature:75°c for bearing & hot air40°c for heater controlrepeatability: ±3°c (refer annexure-3) , motorised valve, actuator type- k300 g1/g2a, enclosure -wt to ip 68, output speed-36 rpm, max tourque-305nm, motor 1.2 kw, 415v, average load-3.10a and locked rotor, 25a (roterz brand) , gate valve (1/2") brass , hex bolt m12*30 , hex bolt m12*50 , hex bolt m6*20 , hex bolt m16* 68 , stud m12*100 , cooling water system , moulded case circuit breaker (mccb), 500a 3p 50ka 415vac, mccb, with magnetic releases, dsine dn3-630m,500a, make-l&t , copper 220v mnx 550/650 spare coil cat no:cs94193(10 each) co , power contactor, 250a, 3p, power contactor with 240v ac coil, aux 2no+2nc contacts, mnx250, make-l&t latch relay, latch relay with 3no+1nc, 240vac coil aux supply with mechnical interlock electrical reset , aux contactor, auxilary contactor

CTN :45652779 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of circuit breaker- ialhk21-1rec5r-34767-1, 2 pole, 10 amp, 74 vdc, with trip coil for auxiliary generator field. medha pt no. sp696131010 [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45640405 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of circuit breaker 2 pole, 10 amp. ,74 vdc with trip coil for ag field to medha code - sp696131010. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45638272 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply, fitting, fixing, testing & commissioning of 100 hp pump starter delta, range-75 kw, fire retardant low smoke internal wiring, starter type-air break, provided with protection degree ip 54, extended wideband coil, class h insulation confirming to is/iec60947-4-1 with pump starter-3 phase, 415volts, 50 hz, contactor size-100a, overload relayrange-70a-100a, auto start switch, manual voltmeter with selector switch, switch suppressed scale ammeter & eocr, ryb indicator motor on & trip led indicator. make-havells/l&t/schneider/abb. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45638273 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply, fitting, fixing, testing & commissioning of fully automatic star delta 50hp, range-37 kw, fire retardant low smoke internal wiring, starter type-air break, provided with protection degree ip 54, extended wide band coil, class h insulation confirming to is/iec 60947-4-1 with pump starter-3 phase, 415 volts, 50 hz, contactor size-50a, overload relay range-34a-50a, auto start switch, manual voltmeter with selector switch, switch suppressed scale ammeter & eocr, ryb indicator motor on & trip led indicator. make-havells/l&t/schneider/abb. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45638278 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply, fitting, fixing, testing & commissioning of fully automatic star delta 150hp, range-110 kw, fire retardant low smoke internal wiring, starter type-air break, provided with protection degree ip 54, extended wideband coil, class h insulation confirming to is/iec60947-4-1 with pump starter-3 phase, 415volts, 50 hz, contactor size-150a, overload relayrange-90a-150a, auto start switch, manual voltmeter with selector switch, switch suppressed scale ammeter & eocr, ryb indicator motor on & trip led indicator. make-havells/l&t/schneider/abb. hsn code- 85369010 [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45631000 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For procurement of spares of 6.6kv ht breakers at chp em ii, 250 mw, tps, parli v - gear box, trip coil , closing coil , auxiliary switch assy, 630a bhel spring charging paul, vcb brkr trip roller assy, tripping mechanism assy, 630a bhel connector, 6.6 kv vcb trip latch with bearing bush, ht 6.6 kv vcb 1250 a bhel suprt insulatr, ckt brkr 630 amp aux switch coller pin, ckt brkr 630 amp aux switch small pin, ckt brkr 630 amp bush pin, motor cut off limit switch, bhel spring charging motor.

corporations/Associations/Others

CTN :45628421 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For tender for supply of spare parts - power contactor 16a at 415v ac coil 24v dc model3tf32 00 0bb4 power contactor biasing damper 24vdc siemens , siemens 3rh1921 1ba01 auxiliary contact block make siemens model 3rh19211ba01 type front top mounted auxiliary contact block contacts 1 no normally open electrical ratings pilot dutyac a600 600 v ac 10 a continuous dc q600 300 v , siemens 3rh19211ca01 auxiliary contact block make siemens model 3rh19211ca01type front top mounted auxiliary contact block contacts 1 nc electrical ratings pilot duty ac , siemens 3tf30 100a power contactor aa11 make siemens model 3tf30 100a type power contactor poles 3 main poles rated operational current ac3 9 a at 415 v ac auxiliary contacts 1 no integrated coil voltage 110 v ac 50 60 hz rated insulation voltage ui 690 v utilization category ac3 ac4 mounting din rail or screw mounting standards iec 6094741 is iec60947 4 kw at 400 v ac power contactor silo , 3ua52 002a thermal overload relay make siemens model 3ua52 002a type thermal overload relay current range 10 16 a trip class 10a reset mode manual automatic auxiliary contact 1 no 1 nc rated insulation voltage ui 690 v mounting direct mount to siemens 3tf30 31 contactors or separate base protection of motors against overload phase failure and unbalanced load standards iec 6094741 thermal overload relay swas , siemens 3th30 220a auxiliary contactor relay make siemens model 3th30 220a type auxiliary contactor relay contacts 4 2no 2nc rated operational current ie 10 a ac15 4 a at 230 v 2 a at 400 v rated insulation voltage ui 690 v coil voltage 110 v ac 50 60 hz standard compliance iec 6094751 mounting din rail or panel mounting , semiconductor fuse rating 10a size 000 make siemens , semiconductor fuse rating 2a size 000 make siemens , semiconductor fuse rating 4a size 000 make siemens , semiconductor fuse rating 6a size 000 make siemens , auxiliary contactor coil dc with 2no 2nc contacts model 3th30 22 0bb4 siemens , motor protection with overload relay function mpcb biasing damper 24vdc motor protection circuit breaker size s00 with overload relay model 3rv2111 1da10 overload release setting 22 32 a short circuit release 42 a size s00 function motor protection w overload relay connection type screw terminal screw terminal suitable motor 400v 11 kw biasing damper 24vdc , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating mcb swas make siemens , type 3 pole power contactor make siemens series sirius model 3rt2015 2ab01 coil voltage 24v ac 5060 hz utilization category ac1 18 a ac3 7 a rated voltage up to 690 v motor rating ac3 1point 5 kw 230v 3 kw 400v 4 kw 690v auxiliary contact 1 no 1314 built in terminals main 1l1 3l2 5l3 2t1 4t2 6t3 coil a1 a2 mounting din rail panel standard iecen 60947 41 power contactor silo , motor starter protector mpcb silo motor protection circuit breaker size s00 model 3rv2011 1aa10 standard mpcb size s00 trip function thermal magnetic main application simple motor switching protection connection type screw terminal screw terminal number of poles 3 adjustment range current 1point 1 to 1point 6 a instantaneous release magnetic 21 a trip class 10 operational voltage 20 to 690 v ac insulation voltage 690 v ac surge voltage resistance 6 kv mains frequency 5060 hz mpcb silo , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating swas make siemens , thermal overload relay model 3us50 001k8k current range 8 12point 5 a tolr swas co ordination type 2 25a type 3na make siemens , add on auxialiry c
 Loading, Please wait...

Connect us via What's Up