Web Analytics Made Easy - StatCounter

Sticker Scrap Tenders

Get complete information related to latest Sticker Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sticker Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sticker Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42377006 Due date: 17 Nov, 202517 Nov, 2025 8.97 Lacs
Tender For bid to ras custom bid for services -calibration services; annual maintenance contract (amc) for ground support equipment (gse) and electrical equipment held with icgae puducherry and 848 sqn (cg) shall cover the following salient features: - 1. to maintain all the gse in good working /serviceable condition at all times as per appendix a , b & c 2. one supervisor (diploma equivalent) along with 01 labor technicians to be placed at coast guard air enclave for the daily routine/ monitoring of amc jobs on gse. 3. replacement of all consumables including various graded oil, seals, filters, belts, pneumatic hose, wheels & rubber beading etc. at seller cost as per scope of work / scheduled of requirements. the consumables and oil should be oem specified wherever applicable and for other cases locally available standard quality item which has been checked and cleared for use by station qa cell. 4. painting of gse twice a year in yellow colour paint (two times in entire contract) as per cgae directives after complete removal of old paint to the bare metal and application of new paint up to 50 m on appendix- a s/l-40, 41 and appendix- b s/l 01-04 & 8. painting is not to be undertaken on nuts, bolts, screws and it is to be applied with only approved grease. 5. recharging of nitrogen cylinder (max. 3000 psi with 99.9% purity n2) as mentioned below from central/state govt certified local agency/govt agency with documentary proof for records post n2 charging. hst of cylinder & lp compressor are also to be carried out whenever due with documentary proof. 5.1 appendix- a s/l-02:- 5-6 times per year, max. 3000 psi with 99.9% purity n2 as and when cylinder pressure is less than 500 psi. 5.2 appendix- a s/l-17:- (portable tyre charging rig) 4 times per year. 6. calibration of gauges fitted on gse to be carried out from nabl certified labs as mentioned in appendix a , b & c and certificate to be provided. 7. the scope of works shall include the repairs/ servicing of all the component/equipment of gse including consumables/spares (required for repairing/servicing) the amc firm will bear the cost of repairs of equipment limited to 10% cost of contracted value . 8. in case unit is not satisfied by the service provided by the firm, amc will be terminated after giving warning letter/ notice of one month. it is to be clearly understood that during the grace period of one month, firm will continue to provide services. 9. if the defect / fault is not rectified within 72 hours of its occurrence, this unit deliberate will reserve the right to deduct the proportionate amount for the unserviceability period. 2 10. all the personnel employed for maintenance duty are to be in possession of the following: 10.1 aadhar card and company identity card. 10.2 no police case/vigilance case certificate. 10.3 two sets of uniforms with name of firm embossed/ embroidered on uniform for ease of identification. 10.4 safety shoes, safety gloves, safety helmet, safety goggles of standard quality to be provided to all persons. 11. safety and security of the personnel employed is the responsibility of the firm and any minor or major injury occurring to the individual is not the responsibility of the cgae puducherry or 848 squadron personnel. 12. working hours of the personnel are from 0900-1730 hrs (06 days in week) and they are to provide their contact number to the respective section in charge of gse for contact.

State Government

CTN :42552389 Due date: 24 Nov, 202524 Nov, 2025 NA
Tender For t. e. no - gmscl/d-773 /rc/2025-26 (on rate contract basis) surgical item (57 item) - disposable hypodermic needle size: 22x1", 297700, stainless steel, with needle cap, single use, size: 23x1", disposable hypodermic needle size: 24x1", 380500, stainless steel, with needle cap, single use size:24 x 1.5", disposable syringe 10 ml (without needle), 2003800, sterile single use syringes as per, sterile hypodermic syringe for single use size:5 ml (without needle), 1733900, length: 100 cm diameter: 2non biolable catgut chromic needle :1/2 circle round body 45 mm heavy, absorbable surgical suture polyglactin 910 {synthetic}with needle 1 with 1/2cir rb 40 mm, 428400, stainless steel, with needle cap, single use, size: 26x0.5", disposable spinal needle 22g x 3 .5" inch, 35300, stainless steel, single use,size 25g x 3.5", disposable spinal needle 23 g x 3.5", 218100, length : 90cms. diameter :1 triclosan coated polyglactin 910 1/2 circle rb 30-40 mm, permeable non woven surgical synthetic adhesive tape (non sterile). size: 1.25 cms x 9.1 meter, 117600, non toxic. non pyrogenicclosed distal end coned withradio-opaque material foraccurate placementsoft, frosted and kinkresistant pvc tubing,sterile by eto ,color coded funnel end connector for easy identification of size., ryles tube(eto sterilized),size-10., 7600, non toxic. non pyrogenicclosed distal end coned withradio-opaque material foraccurate placementsoft, frosted and kinkresistant pvc tubing,sterile by eto ,color coded funnel end connector for easy identification of size, combined spinal/epidural mini pack and needle set containing 18 g epidural mini pack and 26 g lancet tip spinal, 269000, 1) double lumen central venous indwelling catheter : polyurethane radio opaque with a soft tip,size- 7 f: 16 g/16 g. length 15 cm, 20 cm 2) introducer needle:y needle with check valve to provide a second port 3) guide wire :j- tip, kink resistance, soft tip, resilient, with length markings 4) scalpel5) dilator 6) catheter holder for fixation 7)fully transparent extension line with colour coded hub with white slide clamp, air tight closure at injection port 8)injection cap 9) must have sterile dressing, pigtail catheter with needle size -14 f, 54700, iso 13485 as amended from time to timepigtail catheter set for dranage.size of needle-:16 f with guide wire diameter of 0.046".length-:35-40 cm appox,cathater material-:tpu.troccar needle-:stainness steel.trocar stylet-:stainness steel. cathater introduction stiffening canula -1,multihole drainage cathater-1., insulin syringes - 40 iu, 241100, haemostatic sponge in surgical procedure pharma grade, pure gelatin size-8x3 cm, monofilament polyamide black (non absorbable) 38 mm ,10/0 (0.2 metric), sterilized surgical needle suture ,with needle suture, with two needles (double arm) spatulated 6 mm, 3/8 circle needle, 38300, polyglactin 910- 4 inch/10 cm ,10/0(0.2 metric),sterilized surgical needle suture, with needle spatulated 6 mm,3/8 circle needle, double lumen central venous cathater size : 9 f 13 g/13 g length 15 cm 20 cm, 192200, iso 13485 as amended from time to time tube size : 28 fr bag capacity : 2000 ml specially designed kit for post-operative abdominal drainage consists of super smooth rainage catheter along with a collection bag.made from non-toxic and non- irritant medical grade pvc.provided with specialised foldable handle which holds the tube upright prevents accidental kinking during handling & suitable for bedside hanging.soft & smooth catheter with large atraumatic eyes for efficient drainage.radio-opaque line throughout catheter length help x-ray visualization.catheter is color coded for instant size identification.sterile individually packed in peelable pouch.unit consists of : soft drainage catheter 50 cm long collection bag of 2000 ml capacity. transparent with volume measurement marking., pvc abdominal drain kit no 32 fr, 61700, iso 13485 as amended from time to time10 x 10 cm collagen sheet should be 100 percentage natura
 Loading, Please wait...

Connect us via What's Up