Get complete information related to latest Stretcher Insulation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Stretcher Insulation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Stretcher Insulation Tenders.
Tender For tender for supply of supply of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexureiii-a , supply of cassette ac four way capacity 3 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of cassette ac four way capacity 4 tr rating inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4tr cassette acorsplit ac unit refer annexureiii-a , providing flexible pvc duct hose covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte ac units refer aneexure iii-a , providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureiii-a , providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexureiii-a , supply of rain proof outdoor duty as per ip-66 electrical control panel with incommer 4 pole mccb 100 amp digital voltmeter digital ammeter indication lamps refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 4 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 6 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor laying of the same in by eic 4core - 25 sqmm refer annexure-iii-a , supply of following size lt power cable with copper conductor as directed by eic 4core - 16 sqmm refer annexure-iii-a , supply of copper cable of size 4core - 2point5 sqmm for communication , supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness , supply of perforated hot dipped galvanised iron cable tray of size 300 mm width x 50 mm depth x 1point6 mm thickness , installation testing and commissioning of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotaryorscroll compressor aircooled refer annexure-iii-b , installationtesting and commissioning of cassette ac four way capacity 3 tr minimum 3 star rating inverter type refer annexure-iii-b , installation testing and commissioning of cassette ac four way capacity 4 tr inverter type rotary or scroll compressor units refer annexure-iii-b , erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4tr cassette acorsplit ac unit refer annexure-iii-b , laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable refer annexure-iii-b , laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexure-iii-b , laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-iii-b , erection testing and commissioning of rain proof outdoor duty as per ip-66 electrical control panel annexure-iii-b , laying of following size lt power cable with copper conductor xlpepvc insulation pvc inner sheathed armoured extruded pvc oas directed by eic 4 core - 4 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation as directed by eic 4 core - 6 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conducto as directed by eic 4 core - 25 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvcas directed by eic 4 core - 16 sqmm refer annexure-iii-b , laying of copper cable of size 4 core - 2point5 sqmm for communication , installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness , installing
Tender For supply of 4 core 240 sqmm pvc insulated heat resistant electrical cable. aluminium conduct or for working voltage upto and including 1100 volts, bis marked and insulation compound is type- c and t ype st-2 conformity of the specification as per is - 1554 (part i) : 1988 or latest amendment, frlsh c2 cla ss,identification and packaging specification is is - 1554 (part 1) : 1988 or latest with all the relevant test c ertificates [ warranty period: 30 months after the date of delivery ]
Tender For vc and electric equipment for vwdc for various district court (36 places) in rajasthan state - part a, wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) in recessed isi marked mms ( is:9537 p - iii ) virgin material pvc conduit & its isi marked (is:3419-1988) accessories, round tiles, 1.2 mm thick hot dipped galvanized modular box with earth terminal, 10a modular switch,modular face plate with grid plate, 3 pin ceiling rose / holder /3 way connector, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical/ wiring accessories refer chapter e - 04, e - 05 & e - 07 for additional technical parameters of product / work refer annexure a attached with this bsr, short point (up to 3 mtr.), medium point (up to 6 mtr.), long point (up to 10 mtr.), wiring of 3/5 pin 6 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade(is:694) in recessed isi marked mms ( is:9537 p - iii ) pvc conduit & its isi marked (is:3419-1988)accessories, hot dipped galvanized modular box of 1.2 mm thick with earth terminal, 10 a modular switch, 3/5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical/ wiring accessories refer chapter e - 04, e - 05 & e - 07 for additional technical parameters of product / work refer annexure a attached with this bsr, on board, s&f following sizes (dia.) of isi marked virgin material mms ( is:9537 p - iii ) pvc conduit along with isi marked (is:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr, 20 mm, 25 mm, s&f following sizes of isi marked ( is:14927 p - ii ) virgin material upvc trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. for additional technical parameters of product / work refer annexure a attached with this bsr, 25 mm x 12 mm, supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked (is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, class 5 stranding in acc. to is:8130/iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a/c/d , flame retardant as per is 10810-53, better amperage rating as per is:3961 part 5, in existing surface or recessed pvc/ ms conduit/casing capping making connections with copper lugs of suitable size, ferrules,testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr, 3x 1.5 sq.mm, 2 x 2.5 sq. mm. + 1x1.5sqmm, 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm., providing & fixing of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,0
Tender For supply of loom tape , insulation tape electrical pvc adhesive , loom pipe large , loom pipe small , cable electric , leather clothe black , dentrite sr 998 , throttle body cleaner , wd 40