Tender For - 4711 plan (major drainage) sub work:- supply of 2 nos. fibre reinforced plastic/glass reinforced plastic air conditioned boats with enclosed cabin for vvips/vips.
Tender For ????? ???? ?? ?????? ???? ????? ????? ??????? ?? ??????? ????? ?? ?? ???? ????? ?? ?????, ????? - work of laying drain from doodhwa main stand towards udaysagar pond for drainage of dirty water, doodhwa
Tender For repair & renovation of head work, earth work of bund at rd. 0 m. to 1680 m., head sluice, spillway, outlet for drainage & chowkidar quarter of kopara tank scheme.
Tender For general reconstruction of damaged cultvert and providing drainage facilities to 8th mile dietpady muriankal road at ch3 800 km work general civil work
Tender For general reconstruction of damaged culvert and providing drainage facilities to velloor ayarkunnam road at ch 2 900 km work general civil work
Tender For general-drainage system and toilet work in government goat farm attappady,kottathara (po) in palakkad district-electrical worksgeneral electrical work
Tender For corrigendum : general budget work 2025 26 20 improvements to bm bc for chengottukavu ulloorkadavu road b w km 0 000 to 2 430 upgarding mss to bm bc with drainage facilities general civil work
Tender For special repair to adarsh nivasi sala (kumar) at rajkot (pro. grill, repairing toilet block, glazed dedo, drainage line and miscellaneous civil work) [job no: city / raj / special repair / n.r./ 2024-25/ 116] (second attempt)
Tender For corrigendum : provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, brea