Get complete information related to latest Swing Door Bolt Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Swing Door Bolt Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Swing Door Bolt Tenders.
Tender For supply of set of gear case items. one set consist of 13 items- (1). stud bolt m10 x 35- 8.8 (galvanized) drawing no. 1209-01.413-015, qty.-270 nos. (2). loctite 638 (50ml), make- henkel or equivalent, qty.-10 nos. (3). cover assembly to drawing no.1209-01.411-037, qty.-60 nos. (4). sealing plate to drawing no.1209-01.411-038, qty.-60 nos. (5). oil indication label to drawing no. 1209-01.411-043, qty. 120 nos. (6). oil level gauge r2 to drawing no. 1209-01.313-016, qty.-120 nos. (7). magnetic sealing plug r 3/4 inch to drawing no. 1209-01.413-021, qty.-75 nos. (8). hex head sealing plug g 2 inch steel din-910, qty.-75 nos. (9). safety washer vs 10 spring steel to drawing no. 1209-01.411-046/003, qty.-450 nos. (10). safety washer vs 12 spring steel to drawing no. 1209-01.411-046/004, qty.-720 nos. (11). protective arrangement detail for oil level gauge 2 inch to drawing no. 1209-01.313-022, qty.-150 nos. (12). loctite 262 or 271 or 603, make- henkel or equivalent, qty.-10 nos. (13). loctite 767 anti seize paste or optimal paste t.a., make- henkel or equivalent, qty.-10 nos. [ warranty period: 30 months after the date of delivery ]
Tender For supply of power transformer 1000 kva 33 x 0. 4 kva , safe electrode earthing 393 hdg 76 mm dia x 3000 mm with 2 bfc electrodite , safe electrode earthing 393 cp 76 mm dia x 3000 mm with 2 x bfc electrodite , gi earthing strip hot dipped galvanized , copper flat strip 50 mm x 6 mm , frp chamber cover , pvc xlpe cable 1c x 400 sq. mm , alu. arm 1. 1 kv , brass gland double compression 45 mm , ms steel fabricated structure with nut and bolt , installation, testing and commissioning charges for 33 kv 1000 kva transformer along with allied work. , dismantling and shifting of existing 500 kva transformer 33 along with allied work. , installation, testing and commissioning etc , busbars aluminum bus bar 4p 415volts 3phase , pvc xlpe cable 3. 5c x 150 sq. mm, alu. arm 1. 1 kv , lt straight through joint heat shrinkable for 3. 5 c x 150 sqr mm lt cable , installation charges for lt straight through joint heat shrinkable for 3. 5 c x 150 sqr mm lt cable
Tender For supply of anchor link fitment bolt, nut and washer set consisting of items no. : 2, 3 & 4 as per icf drg. no.: t-0-7-613, alt. with galvanized.
Tender For corrigendum : supply , storage, handling, erection, installation, commissioning and testing of electrical equipment like power and control cable ,cable trays and supports lighting system and earthing system at rr site in oesc system. - supply and installation of following pre-fabricated and galvanized cable tray supporting structure materials as per specification, tender drawing (raps-1to8/ 01652/2053/ga) and reference drawings nos. kapp-3&4/ 21490/ 2002, 2003 & 2004/dd., 22 (22 mm dia) first rod with m22x55 long threading on one end & m 22 hex nut, isa 65x65x6, 22 (22 mm dia) rod, isa 65x65x8, ismc 75 channels, couplers (36 odx6 thk.), weld attachment (made of 75x10 thk. plate,320 long), swivel washer seat (46 x16 thk.), swivel washer (40 x16 thk.), iso 1234, 3.5x32 spilit pin, shear bolt m10x70 with hex. head & nut & washer, iso 1234, 3.5x20 split pin, washer (48 , is 2016), 3 mm thick l clamp with m8x30 mm long bolt, 2 plain washer, 1 spring washer and nut, 600mm long, 30 mm wide & 2.5 mm hot dip galvanized strip with two nos. of m8x30 mm long bolt, 4 plain washer, 2 spring washer and 2 nuts, supply and installation of following sizes of 1100v rated, cu conductor, xlpe insulated, frls pvc (st2) inner and outer sheathed un-armoured power cables along with wooden cable drums, 3cx2.5 sq.mm, 4cx2.5 sq.mm, 2cx2.5 sq.mm, supply and installation of following medium duty gi pipes/ heavy duty erw rigid conduits for routing cables from cable trays to distribution boards or to various field equipment or between equipment as directed by engineer- in- charge., 100 mm dia pipe, 65 mm dia pipe, 40 mm dia pipe, 25 mm dia conduit, supply and termination / connection of following types and sizes of 415v power cables at both ends along with cable glands, lugs, ferrules, clamps, hardware etc., and drilling of gland plates, crimping of lugs for termination of following cables (source end & load end considered separately)., supply of 3.5cx300, al, unarmoured, supply of 3.5cx185, al, unarmoured, supply of 4cx16, cu, unarmoured, supply of 3cx6, cu, unarmoured, supply of 4cx2.5, cu, unarmoured, supply of 3cx2.5, cu, unarmoured, supply of 2cx2.5, cu, unarmoured, termination / connection of 3.5cx300, al, unarmoured, termination / connection of 3.5cx185, al, unarmoured, termination / connection of 4cx16, cu, unarmoured, termination / connection of 3cx6, cu, unarmoured, termination / connection of 4cx2.5, cu, unarmoured, termination / connection of 3cx2.5, cu, unarmoured, termination / connection of 2cx2.5, cu, unarmoured, supply and termination of lugs for the following power cables (suitable bi-metallic connector shall be provided for termination of aluminium cable on copper bus bar) (neutral core lug shall be of suitable size)., lugs for 3.5cx300, al, unarmoured, lugs for 3.5cx185, al, unarmoured, lugs for 4cx16, cu, unarmoured, lugs for 3cx6, cu, unarmoured, lugs for 4cx2.5, cu, unarmoured, lugs for 3cx2.5, cu, unarmoured, lugs for 2cx2.5, cu, unarmoured, supply and installation of mortar based fire stops and fire break for all floor & wall openings of cable trays and in the run of cable trays and for sealing of electrical conduits including supply of structural steel support material if required., supply of 3 hr. rated fire stop for cable penetration in floor/walls + fire stop for cable/wire conduits & pipe sleeves, supply of 30 minute rated fire retardant compound (fire break) over cable, installation of 3 hr. rated fire stop for cable penetration in floor/walls + fire stop for cable/wire conduits & pipe sleeves, installation of 30 minute rated fire retardant compound (fire break) over cable, supply and installation of following sizes of gi conduits including supply & installation of all accessories like bends, elbows, couplers, hospital saddles, spacers, gi junction boxes, gi pull boxes, etc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per specification and draw
Tender For supply and fixing of open gym equipments at park in iit kanpur - p/f of shoulder wheel having followingspecifications. size: 1370 mm x 1160 mm x 1610 mm. made of 4mm thick ms pipe. main post made of 114 mm pipe support diameter 80/60/40 mm. the base ate made of 235 mm diameter. seating & foot hold is plastic alloy, uv protectable 1 years and lead free. base cover is virgin lldpe, 8 mm thick, uv protectable 1 years and lead free. powder coated pure polyester desired color 110-150 microns, uv protectable for 1 years and lead free. the bearings are maintenance free and oil sealed. equipment is manufactured and constructed only of materials that have a demonstrated durability. metals subject to structural degradation such as rust or corrosion are painted, galvanized or otherwise treated. plastics and other materials that experience ultraviolet (uv) degradation are uv protected. moving suspended elements are connected to the fixed support with bearings or bearing surfaces that serve to reduce friction and wear. fasteners are made of galvanised & cannot be loosened without tools nuts and bolts have a means to prevent detachment. all the open ends of pipes and bolts with socket are covered by means of lldpe caps and base cover respectively including making of 1:2:4 cc platforms having dimensions 2ft x 2ft x 2ft with flanges, nut and bolt for fixing of equipment required at site, complete in all respect as per specifications and to the entire satisfaction of engineer-in- charge. nothing extra shall be paid on this account., p/f of leg press having followingspecifications.size: 2170 mm x 740 mm x 1670 mm made of 4mm thick ms pipe. main post made of 114 mm pipe support diameter 80 / 60 / 40 mm. the base plate made of 235 mm diameter. seating & foot hold is plastic alloy, uv protectable 1 years and lead free. base cover is virgin lldpe, 8 mm thick, uv protectable 1 years and lead free. powder coated pure polyester desired color 110-150 microns, uv protectable for 1 years and lead free. the bearings are maintenance free and oil sealed. equipment is manufactured and constructed only ofmaterials that have a demonstrated durability. metals subject to structural degradation such as rust or corrosion are painted, galvanized or otherwise treated. plastics and other materials that experience ultraviolet (uv) degradation are uv protected. moving suspended elements are connected to the fixed support with bearings or bearing surfaces that serve to reduce friction and wear. fasteners are made of galvanised & cannot be loosened without tools nuts and bolts have a means to prevent detachment. all the open ends of pipes and bolts with socket are covered by means of lldpe caps and basecover respectively including making of 1:2:4 cc platforms having dimensions 2ft x 2ft x 2ft with flanges, nut and bolt for fixing of equipment required at site, complete in all respect as per specifications and to the entire satisfaction of engineer-in- charge. nothing extra shall be paid on this account, p/f of air walker having followingspecifications.size: 1330 mm x 66 mm x 1400 mm made of 4mm thick ms pipe. main post made of 114 mm pipe support diameter 80/60 / 40 mm. the base plate made of 235 mm diameter. seating & foot hold is plastic alloy, uv protectable 1 years and lead free. base cover is virgin lldpe, 8 mm thick, uv protectable 1 years and lead free. powder coated pure polyester desired color 110-150 microns, uv protectable for 1 years and lead free.the bearings are maintenance free and oil sealed. equipment is manufactured and constructed only of materials that have a demonstrated durability. metals subject to structural degradation such as rust or corrosion are painted, galvanized or otherwise treated. plastics and other materials that experience ultraviolet (uv) degradation are uv protected. moving suspended elements are connected to the fixed support with bearings or bearing surfaces that serve to reduce friction and wear. fasteners are