Get complete information related to latest Switch Tripping Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Switch Tripping Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Switch Tripping Unit Tenders.
Tender For corrigendum : procurement of various switchgear material like timers and overload relays etc. of l&t make suitable for l&t switch gear panel of em&mrt,i&c- stage-iv.
Tender For corrigendum : providing of customized amc/cmc for pre-owned products - 9070c25c94 servicing of 6 point 6 kv and 11 kv abb make vd4 ht switchgear breakers and ht panel verticals through the oem at iocl paradip refinery and paradip petrochemical block on single tender proprietar..
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
Tender For augmentation of 33/11 kv, 1x20 mva and 1x16 mva transformer with 2x25 mva transformer including replacement of outlived 01 no. 11 kv switchgear panel board with new 11 kv panel board and complete civil works at 220 kv substation patparganj
Tender For supply, installation, testing and commissioning of 145kv sf6, 2500a bus coupler switchgear including cnr panel and allied accessories in the outdoor yard of 105 mw (3x35) ushp-ii, kangan hep
Tender For sic of submersible pump set and all allied e/m equipment for rebored tube well near h.no.-116c shahpur jat in greater kailash constituency ac-50. - supply of submersible pump set fitted with dynamically balanced ss impeller mounted on stainless steel shaft with protection sleeve having stage bowl & closed grained shorted type impeller, the pump will be directly coupled to required wet type induction motor of 7.5 hp, 10 stage, speed 2900 rpm suitable for operation of 3 phase, 415 volt, 50 hz, ac supply with efficiency 70% at following duty point:200 lpm on 90 mtr. head. having discharge outlet 50 mm and outside dia 142 mm.make: bs/skope/ any djb approved make, supply of hut type electrical feeder pillar / fabricated with 50 x 50 x 6mm angle iron and 16 swg ms sheet with horizontal and vertical intermediate member of suitable size. i.e. 1370 mm x 760mm x 460 mm. with arrangement for mounting of switchgear and electrical energy meter i.c. painting heaving following item fitted.a) mccb 63 amp, 4pole, 415volt, 35 ka -1 no.b) rccb 63 amp, 4pole with earth fault indication protecting a circuit automatically in the event of earth leakage sensitivity 100ma, - 1 noc) fully automatic star delta starter of relay range 13-21 amp. (7.5 hp to 10 hp) 3 phase oil immersed type -1 no.d) ampere 96 x 96 mm. square shape 0-30 amp-1 no.e) voltmeter 96 x 96 mm. square shape 0-500 volt-1 no.e) indicating lamp (a set of 3 lamps) 1.setf) shunt capacitor of 10 kvar mpp type with three phase isolator with suitable bankingg) motor protection assembly with earth leakage protection phase sequence corrector, single phasing, protection, overload protection, high voltage / low voltage protection time delay power on, programmable time switch i.c. r&b phase facility to change over from automatic, to manual &vice verse for up to 10 h.p -01 nos. complete wiring & installation of above accessories with required copper conductor wire and thimble etc. 01 job.make of all components: any djb approved., s/o pvc insulated & pvc sheathed cable with plain copper conductor having 3 phases, 3 core flat for submersible motor of 4 square mm size each 100 mtrs.make:grandlay / havells./any djb approved make, s/o m.s. clamp of 600 mm length duly fabricated out of 12.5 mm thick 75 mm wide, m.s. plate for holding the pipe of 50 mm dia., s/o double flange gi column pipe 50 mm dia medium class each of 3 mtrs long duly threaded on both ends, welded fitted with gi flange on both ends with slot of submersible cable. make: tata/ jindal./any djb approved make, s/o/ tail piece of the medium class gi pipe 500 mm long with one end threaded as per outlet of pump & another end flanged as per size of gi pipe 50 mm dia., s/o gi 90 bend of size 50 mm dia having both side flange (heavy duty)., s/o nut & bolts of 1/2 dia of different size i.e. 1.5 dia& 2.5 long full threaded., s/o rubber packing for 50 mm dia flange., fabrication and supply supply of bore cover approx size 8-10 inch diameter made out from 6mm thick m.s. sheet in 2 halves & a circular hole in centre 3-1/2 dia. with locking arrangement by nuts & bolt., earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., installation of t/well by lowering of sub p/set with all allied above items. this includes installation and grouting of panel boards with all electrical wiring & cabling at site. all tools & tackles i/c. tripod chain pulley blocks etc. shall be arranged by the firm. this includes testing & commissioning of t/well on load at site i/c. cartage, loading & unloading of material. it also includes a trial run of 30 hrs operation successfully by the firm. all required civil work included in the scope of work.
Tender For aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules