Web Analytics Made Easy - StatCounter

Switchyard Spares Tenders

Get complete information related to latest Switchyard Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Switchyard Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Switchyard Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38474066 Due date: 23 Dec, 202423 Dec, 2024 NA
Tender For corrigendum : supply of switchgear amc for mdpl - ht breaker _isolator servicing at mundra , lt breaker servicing at mundra , earthing trolley maintenance at mundra , relay calibration _electromec_ at mundra , relay calibration _numerical_ at mundra , relay calibration _aux_ at mundra , vacuum bottle testing at mundra , 3rd harmonic test-la_surge arr at mundra , calibration-kwh,mw,mva,mvar at mundra , calibration-multifunction meter at mundra , thermography-station equipment at mundra , breakdown visits mandays at mundra , ht breaker _isolator servicing at bachau , lt breaker servicing at bachau , earthing trolley maintenance at bachau , relay calibration _electromec_ at bachau , relay calibration _numerical_ at bachau , relay calibration _aux_ at bachau , vacuum bottle testing at bachau , 3rd harmonic test-la_surge arr at bachau , calibration-kwh,mw,mva,mvar at bachau , calibration-multifunction meter at bachau , thermography-station equipment at bachau , breakdown visits mandays at bachau , ht breaker _isolator servicing at santalpur , lt breaker servicing at santalpur , earthing trolley maintenance at santalpur , relay calibration _electromec_ at santalpur , relay calibration _numerical_ at santalpur , relay calibration _aux_ at santalpur , vacuum bottle testing at santalpur , 3rd harmonic test-la_surge arr at santalpur , calibration-kwh,mw,mva,mvar at santalpur , calibration-multifunction meter at santalpur , thermography-station equipment at santalpur , breakdown visits mandays at santalpur , ht breaker _isolator servicing at palanpur , lt breaker servicing at palanpur , earthing trolley maintenance at palanpur , relay calibration _electromec_ at palanpur , relay calibration _numerical_ at palanpur , relay calibration _aux_ at palanpur , vacuum bottle testing at palanpur , 3rd harmonic test-la_surge arr at palanpur , calibration-kwh,mw,mva,mvar at palanpur , calibration-multifunction meter at palanpur , thermography-station equipment at palanpur , breakdown visits mandays at palanpur , ht breaker _isolator servicing at pindwara , lt breaker servicing at pindwara , earthing trolley maintenance at pindwara , relay calibration _electromec_ at pindwara , relay calibration _numerical_ at pindwara , relay calibration _aux_ at pindwara , vacuum bottle testing at pindwara , 3rd harmonic test-la_surge arr at pindwara , calibration-kwh,mw,mva,mvar at pindwara , calibration-multifunction meter at pindwara , thermography-station equipment at pindwara , breakdown visits mandays at pindwara , ht breaker _isolator servicing at auwa , lt breaker servicing at auwa , earthing trolley maintenance at auwa , relay calibration _electromec_ at auwa , relay calibration _numerical_ at auwa , vacuum bottle testing at auwa , 3rd harmonic test-la_surge arr at auwa , calibration-kwh,mw,mva,mvar at auwa , calibration-multifunction meter at auwa , thermography-station equipment at auwa , breakdown visits mandays at auwa , ht breaker _isolator servicing at ajmer , lt breaker servicing at ajmer , earthing trolley maintenance at ajmer , relay calibration _electromec_ at ajmer , relay calibration _numerical_ at ajmer , vacuum bottle testing at ajmer , 3rd harmonic test-la_surge arr at ajmer , calibration-kwh,mw,mva,mvar at ajmer , calibration-multifunction meter at ajmer , thermography-station equipment at ajmer , breakdown visits mandays at ajmer , ht breaker _isolator servicing at jaipur , lt breaker servicing at jaipur , earthing trolley maintenance at jaipur , relay calibration _electromec_ at jaipur , relay calibration _numerical_ at jaipur , vacuum bottle testing at jaipur , 3rd harmonic test-la_surge arr at jaipur , calibration-kwh,mw,mva,mvar at jaipur , calibration-multifunction meter at jaipur , thermography-station equipment at jaipur , breakdown visits mandays at jaipur , lt breaker servicing at vadodara , relay calibration _electromec_ at vadodara , relay calibration _numerical_ at vadodara , calibrationmultifunction meter at vadodara , thermo

Central Government/Public Sector

CTN :38350074 Due date: 18 Dec, 202418 Dec, 2024 84.03 Lacs
Tender For corrigendum : provision of tyre killers hydraulic bollards and boom barriers at dabh airport indore - sitc of electro- hydraulic bollard systems completed as required. , design,sitc of automatic boom barrier vehicle gate - 6.8 mtrs. , design,sitc of automatic boom barrier main entry gate - 7.1 mtrs. , design,sitc of automatic boom barrier exit gate - 7.3 mtrs. , design,sitc of automatic boom barrierrefueller gate - 6.0 mtrs. , design,sitc of automatic boom barrier new fire station gate - 10 mtrs. , sitc of electro hydraulic tyre killermain entry gate - 7.1 mtrs. , sitc of electro hydraulic tyre killer exit gate - 7.3 mtrs. , sitc of electro hydraulic tyre killer new fire station gate - 10 mtrs. , supply of 4p, 63 a mccb 25 ka in suitable size enclosed box . , supply of 4x25 sqmm xlpe insulated, 1.1 kv grade power cable , supply of 63 mm dia od size hdpe pipe. , laying of hdpe pipe up to 63 mm dia , laying of xlpe power cable upto 35 sq. mm , laying of xlpe power cable of 1.1 kv grade up to 35 sq. mm. , laying and fixing xlpe power cable of 1.1 kv. up to 35 sq. mm. , supplying and making end termination. 4 x 25 sq. mm 28mm. , earthing with g.i. earth pipe 4.5 metre long. , supplying and laying 25 mm x 5 mm g.i strip. , providing and fixing 25 mm x 5 mm g.i. strip. , providing and fixing 25 mm x 5 mm g.i. strip on surface.

Central Government/Public Sector

CTN :38338993 Due date: 21 Dec, 202421 Dec, 2024 19.50 Lacs
Tender For corrigendum : repair and maintenance of 33/11 kv substation transformer, earthing and other connected accessories at military station agartala

CTN :38581143 Due date: 18 Dec, 202418 Dec, 2024 5.05 Lacs
Tender For operation and maintenance of electrical & mechanical services like internal & external lights & fans, fixture, panels, distribution system, sub-station, passenger lift, unitary ac, water pump set, fire extinguisher etc. at msme-testing centre, kolkata building during 2024-25. (power point wiring, provide & fixing of, mcb/mcbdb & earthing)subwork/packages:power point wiring, provide & fixing of mcb/mcbdb & earthing

corporations/Associations/Others

CTN :38297192 Due date: 20 Dec, 202420 Dec, 2024 12.99 Lacs
Tender For corrigendum : work of erection of 66kv sub-station equipment, structures, earthing, control wiring etc. for new line bay and other work approved under ksy at various s/s under koyali tr division of jambuva circle.

CTN :38526292 Due date: 08 Jan, 202508 Jan, 2025 39.38 Crore
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv disc insulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv disc insulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar

CTN :38508599 Due date: 18 Dec, 202418 Dec, 2024 2.34 Lacs
Tender For s/i of additional safety items for krishi radio station at main campus shalimar, skuast-k.(capex) - fire detection & alarm system, supplying, installation, testing & commissioning sector control panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per is:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required., 4 zone, supplying, installation, testing & commissioning of heat detector each operating at 54 c/57 c with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required., supplying, installation, testing & commissioning of smoke detector each with builtin led and mounting base complete with all connections etc. as required., supplying, installation, testing & commissioning of manual call each boxes of ms construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as recuired, supplying, installation, testing & commissioning response indicator each on surface/recess ms box having two leds metallic cover complete with all connections etc. as required., supplying, installation, testing & commissioning fire alarm sounder each with facility to make announcement, mounted in a.b.s. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required., supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with p.t.t. knob & speaker/microphone enclosed in a m.s.(16 swg)/ abs box with break glass in front etc. complete as required., supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000v rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (epr) insulation and lszh inner bedding, steel wire armouring & lszh outer sheath complete as required., supplying and fixing of co2 type fire extinguisher isi marked confirming to is: 15683 capacity 4.5 kg complete with delivery hose horn, squeeze grip release valve , locking arrangement, operation manual, bracket with two screw and sleeve including transportation cartage upto various post in kashmir region of sib as per anexure attached etc complete as required. (make : life guard/minimax/safeguard), providing and fixing abc type (dry power type ) extinguisher as per is: 15683 consisting of welded ms cylindrical body, with discharge hose, discharge valve, suspension bracket, initial filling, pressure gauge including transportation cartage upto various post in kashmir region of sib as per anexureattached.etc complete as required. (make : life guard/minimax/safeguard), capacity 6 kg., fabrication, supply, installation, testing & commissioning of indoor type compartmentalized feeder pillar having front area not less than 0.60 sqmtr (900 mm x 900 mm) and depth 45 cm (ns) made out of 2mm thick crca sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 400 amp four pole aluminium bus bar of full length with base frame made out of 50mmx50mmx6mm (thick) angle iron having 80cm legs for erection in ground with construction of cement concrete suitable foundation size complete with connections and interconnections with copper conductor pvc insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd.details as under panel powder coated 2.0mm mccb 160 a 4p 50ka , ther

Central Government/Public Sector

CTN :38494402 Due date: 30 Dec, 202430 Dec, 2024 NA
Tender For part(a):bhopal division - provision of divyangjan facilites at stations. (electrical work). part(b):improvement of power supply arrangement of bhopal station. part(c):proposal for new earthing at different locations. part(d):provision of air conditioning at remaining indoor wards (male surgical & male medical) of nsz/hospital.

State Government

CTN :38456088 Due date: 24 Dec, 202424 Dec, 2024 NA
Tender For work of strengthening of existing earthing of power transformer and sub-station transformer by special type deep boring earthing work of 132/33kv grid sub-station, gumla

CTN :38363368 Due date: 18 Dec, 202418 Dec, 2024 NA
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar
 Loading, Please wait...

Connect us via What's Up