Tender For maintenance of electrical installation & fans at sirifort auditorium, new delhi. (sh : supplying and laying of cable & replacement of led street light fittings etc.)
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For comprehensive maintenance of street lighting on pwd roads under west electrical division 2025-26 (sh- reinstallation of 8/10/12 mtr. height street light pole, led fitting, cable laying and feeder piller on ... etc (full name of work mentioned in nit)
Tender For corrigendum : rate contract for supply and installation of network rack with networking equipment, i/o points, laying of lan, optical fiber cable cabling and dismantling of existing network rack and lan cable for offices under mpmkvvcl bhopal for three years
Tender For tender for supply of miscellaneous electrical works of underground mines at narwapahar : : - dismantling and reeling of 1x3c x120/150sqmm 6.6kv cu xlpe double armoured cable as per detailed in gcc , laying dressing and sadling of 1x3c x 120/150sqmm 6.6kv cu xlpe insulated double armoured cable on pre erected cable tray / support including clamping of the same , laying , dressing and saddling of three and half core 185 sqmm xlpe cu armoured cable as per detailed in gcc , laying , dressing and saddling of 3.5cx120 sqmm pvc xlpe insulated copper conductor , round steel flat wire armoured cable as per detailed in gcc , laying , dressing and saddling of two core 4/16 sqmm or three and half core x 35 , 50 , 70 sqmm al conductor armoured cable or ofc as per detailed in gcc , dismantling and reeling of three and half core 185sqmm cu conductor armoured cable as per detailed in gcc , dismantling and reeling of three and half core 120 sqmm aluminium conductor armoured cable as per detailed in gcc , dismantling and reeling of three core 16 sqmm or three and half core70 sqmm al armoured cable or ofc as per detailed in gcc , dismantling and shifting of 5 kva / 10 kva lighting transformer at various places in underground mines , supply of three core 240sqmm 6600 v heat shrink xlpe cable end termination kit with termination of the same as per detailed in gcc , three core 240 sqmm 6600 v heat shrink xlpe cable jointing kit with straight through jointing work of cable as per detailed in gcc , dismantling shifting up to 50 meter and installation of non-flp geb , 300a , 440v at various places in ug mines as per detailed in gcc , dismantling , shifting up to 50 meter and installation of 400a , 440v , junction boxes (existing / new) in underground mines at various places as per detailed in gcc
Tender For bid to ras supply of providing amf panels for various capacity engine alternator set in te bldgs under kollam ba d d - sitc of free standing, outdoor cubicle type microprocessor based amf panel 30 kva , sitc of free standing, outdoor cubicle type microprocessor based amf panel for 20 kva , supplying, laying and fixing of al power cable in pipe , supplying, laying and fixing of al power cable on surface of wall , supplying, laying and fixing of al power cable in masonry open duct , supplying and making end termination with brass compression gland , supplying, laying and fixing of 8 c 1.5sq.mm pvc flexible cable , supplying and laying of 2 x 6 sq mm pvc insulated , supplying, laying of 16 sqmm size frls pvc insulated copper conductor , supplying and laying of industrial telephone cables , supplying and laying of dwc hdpe pipe , supply and fixing the steel wire reinforced flexible upvc conduit , sf 40 mm dia gi pipe , supplying and fixing of medium class pvc conduit , supplying and fixing of spn db , replacement of 12v, stop solenoid , llop sensor , hct hwt sensor , sensor float , start stop relay , 12 v oen pla relay , dismantling of the existing dg control panel , rerouting of the existing cable
Tender For expression of interest for empanelment and selection of bsnl partner (bp) for execution of ftth project including laying of 4f overhead optical fiber cable up to village level in jaipur ba of rajasthan telecom circle