Tender For supply of cable pvc insulated unsheathed un-armoured for electric power and lighting with stranded aluminium conductor single core for voltage up to and including 1100v confirming to rdso specification no : rdso/pe/spec/tl/0027-2002(rev-0) with amendment-1, of size : 7/2.50 mm(35 sq.mm).
Tender For providing of facility management services - lumpsum based - kaps 1 & 2 plant site; assistance for day to day miscellaneous work like lighting maintenance, cable termination, cable laying; consumables to be provided by service provider (inclusive in contract cost)
Tender For supply , storage, handling, erection, installation, commissioning and testing of electrical equipment like power and control cable ,cable trays and supports lighting system and earthing system at rr site in oesc system. - supply and installation of following pre-fabricated and galvanized cable tray supporting structure materials as per specification, tender drawing (raps-1to8/ 01652/2053/ga) and reference drawings nos. kapp-3&4/ 21490/ 2002, 2003 & 2004/dd., 22 (22 mm dia) first rod with m22x55 long threading on one end & m 22 hex nut, isa 65x65x6, 22 (22 mm dia) rod, isa 65x65x8, ismc 75 channels, couplers (36 odx6 thk.), weld attachment (made of 75x10 thk. plate,320 long), swivel washer seat (46 x16 thk.), swivel washer (40 x16 thk.), iso 1234, 3.5x32 spilit pin, shear bolt m10x70 with hex. head & nut & washer, iso 1234, 3.5x20 split pin, washer (48 , is 2016), 3 mm thick l clamp with m8x30 mm long bolt, 2 plain washer, 1 spring washer and nut, 600mm long, 30 mm wide & 2.5 mm hot dip galvanized strip with two nos. of m8x30 mm long bolt, 4 plain washer, 2 spring washer and 2 nuts, supply and installation of following sizes of 1100v rated, cu conductor, xlpe insulated, frls pvc (st2) inner and outer sheathed un-armoured power cables along with wooden cable drums, 3cx2.5 sq.mm, 4cx2.5 sq.mm, 2cx2.5 sq.mm, supply and installation of following medium duty gi pipes/ heavy duty erw rigid conduits for routing cables from cable trays to distribution boards or to various field equipment or between equipment as directed by engineer- in- charge., 100 mm dia pipe, 65 mm dia pipe, 40 mm dia pipe, 25 mm dia conduit, supply and termination / connection of following types and sizes of 415v power cables at both ends along with cable glands, lugs, ferrules, clamps, hardware etc., and drilling of gland plates, crimping of lugs for termination of following cables (source end & load end considered separately)., supply of 3.5cx300, al, unarmoured, supply of 3.5cx185, al, unarmoured, supply of 4cx16, cu, unarmoured, supply of 3cx6, cu, unarmoured, supply of 4cx2.5, cu, unarmoured, supply of 3cx2.5, cu, unarmoured, supply of 2cx2.5, cu, unarmoured, termination / connection of 3.5cx300, al, unarmoured, termination / connection of 3.5cx185, al, unarmoured, termination / connection of 4cx16, cu, unarmoured, termination / connection of 3cx6, cu, unarmoured, termination / connection of 4cx2.5, cu, unarmoured, termination / connection of 3cx2.5, cu, unarmoured, termination / connection of 2cx2.5, cu, unarmoured, supply and termination of lugs for the following power cables (suitable bi-metallic connector shall be provided for termination of aluminium cable on copper bus bar) (neutral core lug shall be of suitable size)., lugs for 3.5cx300, al, unarmoured, lugs for 3.5cx185, al, unarmoured, lugs for 4cx16, cu, unarmoured, lugs for 3cx6, cu, unarmoured, lugs for 4cx2.5, cu, unarmoured, lugs for 3cx2.5, cu, unarmoured, lugs for 2cx2.5, cu, unarmoured, supply and installation of mortar based fire stops and fire break for all floor & wall openings of cable trays and in the run of cable trays and for sealing of electrical conduits including supply of structural steel support material if required., supply of 3 hr. rated fire stop for cable penetration in floor/walls + fire stop for cable/wire conduits & pipe sleeves, supply of 30 minute rated fire retardant compound (fire break) over cable, installation of 3 hr. rated fire stop for cable penetration in floor/walls + fire stop for cable/wire conduits & pipe sleeves, installation of 30 minute rated fire retardant compound (fire break) over cable, supply and installation of following sizes of gi conduits including supply & installation of all accessories like bends, elbows, couplers, hospital saddles, spacers, gi junction boxes, gi pull boxes, etc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per specification and drawings. (the run
Tender For maintenance of street lighting on various roads in various sectors at u.t chandigarh (replacement of existing defunct led street light fitting, led flood light fittings, switchgear, burnt out cable, casting of cement collar and other allied accessori
Tender For maintenance of border flood lighting works for bop no. 1061 to 1097 along indo-pak border at bhuj in gujarat sector (sh- replacement of damaged ug cable loops and earthing accessories in bop no. 1063, 1067 and 1070 for making functional of newly erected bfl poles).subwork/packages:replacement of damaged ug cable loops and earthing accessories in bop no. 1063, 1067 and 1070 for making functional of newly erected bfl poles.
Tender For bid to ras supply of self ballasted led lamps for general lighting services (v2) conforming to is 16102 (q2) , led batten (q2) , molded case circuit breakers (mccb) as per is / iec 60947 (q3) , xlpe cable for working voltages up to and including 1. 1 kv as per is 7098 (part 1) (q2) , plywood coml 8feetx4feetx12mm , plywood coml 8feetx4feetx19mm , ss kitchen rack 90x75cm plate rack , plywood coml 8feetx4feetx6mm , plywood coml 8feetx4feetx4mm