Tender For supply of pn or zener diode or led characteristics apparatus , verification of kcl and kvl , resistance in series and parallel apparatus , ohms law apparatus without power supply , ohms law apparatus with aluminum panel 2 digital panel meters and power supply , transistor characteristics apparatus , fet characteristics apparatus , half wave full wave and bridge rectifier apparatus , ripple factor apparatus , digital logic trainer , verification of truth table of logic gates using universal gates , flip flops using nand gates and ttl ics , four bit counters synchronous and asynchronous , four bit shift registers , encoder or multiplexer eight to one line , decoder or demultiplexer one to eight line , four bit analog to digital convertor , four bit digital to analog convertor , light intensity or phase control using scr or triac , scr commutation techniques , switching action of a bjt , single phase half wave full wave and fully controlled bridge rectifier or convertor using scrs , three phase half controlled bridge converter with r and rl load , three phase fully controlled bridge converter with r and rl load , single phase cycloconverter , instrumentation trainer using transducers , burdon tube pressure gauge trainer kit , strain gauge trainer kit with cantilever beam , lvdt trainer kit , speed measurement using photo electric and magnetic sensors , temperature sensors kit , measurement of water level using strain gauge , measurement of water level using capacitance transducer , ac servo speed torque characteristic trainer , dc servo motor speed torque characteristics trainer , stepper motor controller trainer , analog lab trainer bread board model , digital lab trainer bread board model , plc trainer , transmission line trainer abcd t and pi parameters ferranti effect load test , idmt over current relay testing kit electromechanical type , buchholz relay testing kit with compressor and oil , over voltage relay testing kit electromechanical type , over current and earth fault relay testing kit three phase static type , over current relay testing kit static type , measurement of power and power factor single phase and three phase , to study a typical bhk house wiring , four to one multiplexer and one to four demultiplexer , vapour compression refrigeration vcr test rig , water cooler setup , air conditioning test rig , domestic refrigerator , window air conditioner , split air conditioner , air cooler evaporative , tube cutter , pipe bender , flaring and swaging tool kit , reamer , brazing torch , manifold gauge set , vacuum pump , refrigerant recovery unit , refrigerant charging cylinder or electronic charging scale , refrigerant leak detector , digital clamp meter , digital thermometer , anemometer , tachometer , insulation material , refrigerants , recovery cylinders , weighing machine , electrical control panel , work benches , safety equipment
Tender For bid to ras supply of self regulating heating tape cable e e - title1 , title2 , title3 , title4 , title5 , title6 providing self-regulating heat tape / resistance heating cable suitable for freeze protection of pipelines and utilities, having rated output of 35 w per meter at 220 v ac supply. the heating cable shall automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating. the cable shall be suitable for continuous operation in outdoor conditions, flexible for installation around pipelines, joints and valves, and compatible with temperaturecontroller systems., providing m20 3-pin connector suitable for making secure electrical joints between self-regulating heat cable terminals, designed for reliable power and signal continuity. the connector shall be rated for operation at 220 v ac supply and compatible with heating cables of specified capacity. it shall ensure safe and firm termination, with robust insulation to prevent moisture ingress, short circuits, and electrical leakage.the connector shall be constructed from high-quality, weather-resistant materials, suitable for continuous outdoor operation under varying environmental conditions. it shall provide ease of installation, with a compact and durable design for use at pipeline joints, terminations, and interconnections. the m20 connector shall be compatible with temperaturecontrolsystems and associated accessories, ensuring long-term performance, safety, and protection against overheating, corrosion, and mechanical stress., providing temperature differential controller with auto and manual operation, housed in a robust ip65-rated enclosure, suitable for controlling heat tracing systems to prevent freezing of pipelines and utilities. the controller shall be designed to automatically switch the heat tape on/off based on preset temperature ) /bid number : gem/2026/b/7550906 * /dated: 18-05-2026 & & / bid document 1 / 13
Tender For supply of commercial multifunction steam vessel versatility precise temperaturecontrolsystem with six module tray as per sow , provision of vitrified tile flooring below steam vessel size 8x8 ft pdf layout design mandatory to upload , provision of vitrified tile work with sliding wooden doors below granite cupboard size 10x3 ft , provision of core cutting for fresh water pipeline inlet, electrical wiring inlet drain water outlet , supply and installation of 1 point 1kv grade 16 sq mm 5 core armoured cable x lpe pvc is 7098 with required excavation brick work and cable marker as required 120 rmt approx length , supply and installation of 100 a breaker and 40 a 4pole mccb industrial socket connection , supply and installation of cpvc fresh water pipeline for equipment size 3 by 4 inch 1by 2 inch , supply and installation of commercial g i ducting for steam vessel size length 9 ft with 18 inch exhaust fan , commercial ss table for steam vessel size 3x3x3ft , supply and installation of 25lph industrial ro water purifier with connection , provision of 6w inverter for led touch control panel of steam vessel , installation and commissioning charges if any in addition to above
Tender For bid to ras tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperaturecontroller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperaturecontrolsystems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperaturecontrollers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For purchase of lab equipment for mechanical (workshop) - purchase of lab equipment, 3d printer (technical specification - refer with nit), rp2040 carrier board (technical spectfication - refer with nit), 8051 micro kit vptb (technical spectfication - refer with nit), level controlsystem trainer (technical spectfication - refer with nit), traffic light controlsystem (technical spectfication - refer with nit), stefan boltzma nn apparat us (technical specification - refer with nit)
Tender For tender for repairing and calibration of temperature indicators installed on boiler , work of repairing, calibration and rewiring of superheated wash water temperaturecontrolsystem , laying of comprehensive cable, installation of thermocouple and commissioning of indicators at the boiler station , work of repairing, rewiring, overhauling and commissioning of d- superheating system of exhaust line , repairing and commissioning work of temperature indicators of sulfur furnace , laying of compressive cables of sulfur furnace, installation of sensors and commissioning of temperature indicators , to carry out installation and commissioning work for raw-sulfated juice, clear juice, exhaust steam and injection water inlet temperature , over hauling, rewiring and recommissioning of auto drum water level controlsystem of boilers , rewiring and recommissioning of high or low alarm system on boilers for water level , overhauling, rewiring and recommissioning of boiler steam generation system , overhauling, rewiring and recommissioning of boiler feed water measurement system
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For instrument spare and annual maintenance contract - circular charts:-i) cc-200 (fc-261)range 0-100, ii) 9/d/179/fc-241, range 0-600, iii) 9/d/147/s-8963, range 0-150, iv) 9/d/112/s-3452, range 0-30, disposable pen (red), temperature gauge dial size 6" (h guru) heavy duty with test certificate (mercury filed) :-i) range 0-150 c streight steam 6", ii) range- 0-150 c capillary type (3 meter) bulb length 10" copper/pvc, iii)range 0-300 c streight steam 6", iv) range 0-500 c streight steam 6", vacuum gauge dial size 6" range- 0-30 inch of hg/760 mm bottom feed connection 3/8" bsp, h guru heavy duty with test certificate., pressure gauge dial size 6" bottom feed connection size 3/8" or 1/2" bsp, h guru heavy duty with test certificate :-i) range 0-15 psi 01 kg/cm , ii) range 0-30 psi 02 kg/cm , iii) range 0-60 psi 04 kg/cm , iv) range 0-150 psi 10 kg/cm , v) range 0-300 psi 21 kg/cm , vi) range 0-1030 psi 42 kg/cm /70 kg/cm , pressure gauge, dial size 10" bottom feed connection size 1/2" bsp heavy duty with test certificate:-i) range 0-60 kg/cm h. guru with test certificate, ii) range 0-2 kg/cm2 h. guru with test certificate, pressure gauge for turbines heavy duty with test certificate:-i) 4" dial size side back connection %" bsp range 0-2 kg/cm , ii) 4" dial size side back connection %" bsp range 0-4 kg/cm , iii) 4" dial size side back connection %" bsp range 0-7 kg/cm , iv) 4" dial size side back connection %" bsp range 0-10 kg/cm , teflon coated compensating cable 2 core j type, compensating cable fg/ss 2-core k type, 4 digit digital temperature indicator j & k typ , thermocouple sensor heavy duty:-i. 12" x 8 mm j/k type, ii. 8" x 8 mm j/ k type, iii. 6" x 6 mm j/k type, oil pocket ss 12", 6 digit digital event counter, proximity switch (magnetic sensor) pnp-nc sensing 8 mm,voltage 5-35 vdc, max load 300 ma, on/off pneumatic control valve flange type size- 1" to operate at air pressure 60-80 psi suitable for 20 kg/cm line pressure, on/off solenoid valve for pneumatic valve:-a) air filter " line size female thread, b) air filter with air regulator size 4", digital temperaturecontroller (pid) j & k type, digital tachometer range 0-10000 rpm, 96 x 96 with magnetic sensor., steam flow indicator cum totalizer, drum level controller 4-20 ma input/output model no. 5296at (massibus make), dp transmitter 4-20 ma for boiler drum level, honybell make, positioner for drum level control valve, stroke counter for molasses tank, jumbo digital display with sensor, for juice and water tank, current and previous display size 4" x 4"., ma & mv source meter for temp. indicator calibration, pressure transmiter model tsc 01, range 0 to 40 bar, output 04-20 ma, accuracy 0.25% fs, pressure transmiter model ks-e-e-e b02u-m-v, range 0 to 2 bar, output 04-20 ma, supply 9-32 vdc, port g1/4e, syphon pipe s.s. 304 :-(i) u type, (ii) q type, pressure gauge, model en837-1, ss-316, dail size 6", bottom feed connection size 1/2" bsp, heavy duty with test certificate (tempsens make) :-i) range 0-6 kg/cm , ii) range 0-10 kg/cm , iii) range 0-21 kg/cm , iv) range 0-42 kg/cm , pid controller, size 96 96, model no. dc 1040, make honey bell, pressure recorder range, h-guru make, with test certificate (heany duty) with pipe stand mounted ", socket- ", size 10" :-(i) 0-1 kg./cm2, (ii) 0-2 kg./cm2, (iii) 0-10 kg./cm2, orifice with assembly (nipple), inlet pressure 21 kg/cm , outlet pressure 21 kg/cm , inlet temp. 350 c, outlet temp. 350 c, line size 4", drum level transmitter, range 400 to 400 in h2o, (make- honey bell), steam pressure transmitter, range 14.7 to 3000 psi, (make- honey bell), hade mounted thermocouple, length 450 mm, k-type duplex type, with test certificate (heany duty), signal isolator singal input 4-20ma, double output 4-20ma, repair & calibration work with amcsuper-heated wash water temp. controlling system- 01 no., d-super heated exhaust steam temp. controlling system- 01 no., temperaturecontrolsystem of transit heater for c/f machin