Tender For corrigendum : supply of isolator 400amps 3 3kv reversing part no ht100b , isolator 200 amp 3 3 kv on off part no ht100 , isolator fixed contact set part no ht1001 , isolator moving contact set part no ht1002 , vacuum contactor 400 amps 3 3kv part no ht200 , bridge rectifier unit complete part no ht005 , vacuum interrptor 3 3kv 400a part no ht202 , bottle for vaccum contractor 400 amps 3 part no 201 , vaccum contactor holding coil 110v dc part no 204 , auxiliary switch for vaccum contractor 2 part no 205 , p t 40va 0 8 12v 0 110v part no 206 , auxiliary contactor 3no 1nc 110v ac part no 208 , resin cast p t 750va 3 3kv 110v single part no 300 , isolator handle on off with axel bush part no 1501 , ht control fuse 3 3 kv 2 amps part no 400 , resin cast moulded cbct part no 500 , e l unit complete without transformer part no 800 , single phase preventer cup 20 pfr make part no 2001 , ct oprted ct sec 5a motor prtectn relay part no ht900e , o l rly thrml 4 7 5a ct oprtd w mntng part no 900b , 72sq mm ammeter 0 150 450a part no ht1000 , 72sq mm voltmeter 0 5kv part no ht1100 , ammeter selector switch part no 1001 , hrc fuse base carrier for control part no 1200 , hrc fuse link 4a for control part no 1201 , push button with element for start sto part no ht1300 , lamp holder with lamp on off trip part no ht1400 , power hrc fuse part no 1500 , brass cable gland complete with c i clam part no 1600 , copper bus bar 400 amps set of 3 part no ht101 , undervoltage relay part no ht2000 , static type idmtl over current and short part no ht900a , pilot realy 12dc part no ht2200 , voltmeter selector wsitch part no ht1101 , contactor tp 12 amps ac3 duty fitted wit part no ht200a
Tender For corrigendum : supply of circuit spot 800 amp , operating handle for isolator , castel lock spindle type with key , castel lock box type with key , cable gland-conical type for 70 sqmm x 3 , auxiliary relay 3o by c , vaccum bottle 1250amp 26ka , trip coil , closing coil , limit switch , indicating lamp , ht bushing w by clamp fitting 3 point 3kv 1250a , heavy duty epoxy resin cast potential tr , h v fuse link 6 point 6 kv , earth leakage relay , under voltage relay , over voltage relay , ammeter , voltmeter , ammeter selector switch , voltmeter selector switch , mcb 6amp 2 poles , fuse base , fuse base holder 415v ac 32a , master trip relay , insulator complete set
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply, installation, wiring and testing of a screw jack coach lifting machine. along with 12 pin male and female connector, 05 pin male and female connectors provision of 100a fuse socket including 100afuse necessary indicator/lights green push buttons with elements selector switch and emergencypush buttons suitable range voltmeter and ammeter etc. [ warranty period: 6 months after the date of delivery ] ]
Tender For supply of self starter , pressure plate , air dryer , rpm cable , fog head lamp , hold coil assy , cross universal joint , cock , eng brake switch , selector switch , flasher unit , tie rod end , air brake valve , accelerator cable , gear lever end , water separator , cabin mtg pad , head light switch , indicator switch , switch of head lamps , brush cord , voltmeter , engine stoper cable , hose assy , hose , door beading
Tender For supply of vaccum bottle , spring charging motor , potential transformer epoxy resin cast , h d resin cast ct part no md2231 , trip coil , closing coil , single phase rectifioer or power pack , complete manually operated mechanism , complete vaccum circuit breaker truck , resin cast bottle housing , limit switch , indicating lamp , hv fuse link , h d resin cast ct part no md2214 , h d resin cast ct part no md2217 , earth leakage relay , 4p non directional idmt static relat , master trip relay , multifunctional ai energy meter , digital energy meter 3ph 3 wire , auxillary contactor , ammeter , voltmeter , voltmeter selector switch , hrc fuse link , digital earth leakage relay door mntd 110v , breaking charging handle
Tender For corrigendum : supply of electrotecnica spares : : - 96 sqmm ammeter up to 0 600 120 a ctr 600 5a nvcb v 0014 , 96 sqmm ammeter up to 0 300 600 a ctr 300 5a nvcb v 0015 , 96 sqmm voltmeter 0 point 5 kv ptr 3 point 3 kv 110ac nvcb v 0017 , ammeter selector switch nvcb i 0018 , voltmeter selector switch nvcb i 0019 , 22 point 5 dia indicating lamp led type 110v ac red nvcb i 0023 , 22 point 5 dia indicating lamp led type 110v ac amber nvcb p 0024 , 22 point 5 dia indicating lamp led type 110v ac green nvcb p 0025 , aux voltage 110 v ac ct secondary sa type apr31 hp nvcb p 0029 , push button with element nvcb p 0031 , t n c switch for electrical operated vcb nvcb p 0032 , 3 point 3kv 110v 12v 100 va ph 3ph pt nvcb p 0037 , auxiliary contactor nvcb p 0039