Tender For supply of suction pressure switch, without capillary, suitable for use in lhb type ac coaches, range 30-60/22-58 psi, ps 27/45 bar, ts 30/85 degree centigrade, 6a 250 volt ac, as per danfoss part no. acb-2 ua 439 w, 061f 7294 / alco control ps3-af 3 hnspcn 0713228 / sidwal part no. sr-075-1037a / intec part no. ic-075-1037.accepted make: danfoss / alco or any other make with prior approval of rdso.
Tender For supply of switch disconnector fuse -drawout with front drive and door interlock, suitabie for din type fuse in open exection. cat.no. 3km82113ta20 , siemens make 125a switch disconnector fuse -drawout with front drive and door interlock, suitable for din type fuse in open exection. cat. no. 3km82213ta20 , siemens make 3wl acb_air circuit breaker_,current_rating - 630a, icu-66ka at 500v ac, size-1, 3p,wlthdrawable acb, cat. no. 3wl11063aa361aa4-zp23plusr15plust40plusr30plusr21 , siemens make 3wl acb_air circuit breaker_,current_ratlng - 630a, icu 66ka at soov ac, size-1, 3p,withdrawable acb, cat. no. 3wl11063eg361aa4- zp23plusk07plusr15plust40plusr30plusr21 , siemens make 3wl acb_air circuit breaker_,current_ratlng - 1000a, icu - 66ka at 500v ac, size-1, 3p, cat. no. 3wl11103eg364gg4- zp23plusk07plusc20plust40plusr21pluss05plusr16plusr30 plusf40 , siemens make accessory for 3wl acb_air circuit breaker_, closing coil and tripping coil cat. no. 3wa91110ad06 , siemens make accessory for 3wl acb, spring charging motor cat. no. 3wa91110af06 , siemens make auxillary supply connectors for circuit breaker or guide frames, screw connection. cat. no. 3wa91110ab03 , siemens make male connectors for circuit breakers cat. no. 3wa91110ab01 , siemens make arc chutes for breaker size-1 cat. no. 3wl91110as010aa0 , siemens make arc chutes for breaker size-2 cat. no. 3wl91110as020aa0 , siemens make sliding contact modules for guide frames cat. no. 3wa91110ab08 , siemens make position signalling switches for guide frames cat. no. 3wl91110ah110aa0 , siemens make stored energy status signalling switch. cat. no. 3wl91110ah080aa0 , siemens make auxilary switch blocks. cat. no. 3wl91110ag010aa0 , siemens make mccb with its extension handle, 63a cat. no. 3va1163-3gf46-0aa0 plus 3va9157-0fk51 , siemens make mccb with its extension handle, 40a cat. no. 3va1040-3ed42-0aa0 plus 3va9157- 0fk51 , siemens make mccb with its extension handle, 32a cat. no. 3va1132-3ef36-0aa0plus3va9157-0fk51stock , siemens make mccb with its extension handle, 25a cat. no. 3va1125-3gf42-0aa0 plus 3va9157-0fk51 , siemens make mpcb, 4.5-6.3a cat. no. 3rv2011-1ga10 , siemens make accessories for 3rv1, lateral auxiliary switches with screw terminals mountable on the left _1noplus1nc_ cat. no. 3rv2901-1a , siemens make mpcb, 1.8-2.5a cat. no. 3rv2011-1ca10 , siemens make power contactor, 32a cat. no. 3rt20351af00 , siemens make power contactor, 12a cat. no. 3rt20171af01 , siemens make overload relay, 18-25a cat. no. 3ru2136-4db0 , siemens make overload relay, 4.5-6.3a cat. no. 3ru2126-1gb0 , siemens make overload relay, 1.8-2.5a cat. no. 3ru2126-1cb0 , siemens make contactor cat. no. 3rt2038-1ag20 , siemens make contactor cat. no. 3rt20161af01 , siemens make sfu cat. no. 3ka82315te00 , siemens make mccb cat. no. 3va1116-3ee32-0aa0 , siemens make mccb cat. no. 3va1116-3ed32-0aa0 , siemens make mccb cat. no. 3va1080-3ed32-0aa0 , siemens make mccb cat. no. 3va1040-3ed32-0aa0 , siemens make overload relay _7-10a_ cat. no. 3ru2116- 1jb0 , siemens make independent mounting for olr 3ru1 cat. no. 3ru2916-3aa01 //bid details 2 / 43
Tender For supply of sitc of acb panel , dismantling section of the existing 800 a bus trunking , rerouting and reinstallation of a section of bus trunking , supply and fixing 3 mm thick ms sheet , supply and fixing mechanical interlocking arrangement with lockable trip push button key , making necessary modification in the existing 800 a main lt panel bus bar arrangement , supply , fixing, testing of multifunction meter , supply and fixing led type ryb indicating lamps , dismantling the existing apfc panel , supplying and fixing fire retardant electrically insulated, synthetic mat , sitc of 4.5 kg co2 type fire extinguisher , sitc of 5 kg dcp type fire extinguisher , supply and fixing of gi fire buckets , providing and laying 6mm thick ms chequered sheet , complete painting of the existing rusted chequred plates , preparing the single line diagram of 2x400kva ht substation , supply and fixing the signage , removing the sand in fire buckets , supply and fixing 18 w, 4 feet led batten tube light fitting , complete cleaning of the existing substation room , supplying and fixing 15 or 16 a switch and 6 pin 15 or 16 amp socket outlet on metal box , supplying, installation including suspension, testing and commissioning of 800 amps bus trunking , supplying of 3.5 c x 400 sq.mm cable , supplying of 3.5 c x 300 sq.mm cable , laying of one number pvc insulated power cable in existing pipe , laying of one number pvc insulated power cable in existing masonry duct , laying of one number pvc insulated power cable on surface of wall , supply, fabrication and erection of ms cable tray , supplying and laying of 200 mm dia dwc hdpe pipe , providing and fixing earth bus of 50 mm x 5 mm copper strip , providing and fixing braided copper of equivalent size of 25mm x 5mm strip , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick , providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe , providing and fixing 25 mm x 5 mm copper strip on surface , supplying and making end termination with brass compression gland for 3.5 x 400 sq. mm cable , supplying and making end termination with brass compression gland for 3.5 x 300 sq. mm cable
Tender For supply of high pressure cut out/switch, direct mounting type (cartridge pressure control), suitable for use in lhb type rmpu eog ac coaches, without capillary, range 310-412 psi, ts-22/212 degree fahrenheit, 6/8a, 240 volt ac, as per danfoss make part no. acb-2 uc 87w, 061f 9081 or alco make part no. ps3 w5s, pcn 0713299, conforming to rdso specification no. rdso/pe/spec/ac/0061-2005 (rev-1).accepted make: danfoss, alco or any other rdso-approved make.
Tender For supply of high pressure cut out/switch, direct mounting type (cartridge pressure control), suitable for use in lhb type rmpu eog ac coaches, without capillary, range 310-412 psi, ts-22/212 degree fahrenheit, 6/8a, 240 volt ac, as per danfoss make part no. acb-2 uc 87w, 061f 9081 or alco make part no. ps3 w5s, pcn 0713299, conforming to rdso specification no. rdso/pe/spec/ac/0061-2005 (rev-1).accepted make: danfoss, alco or any other rdso-approved make.