Get complete information related to latest Terminal Block Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Block Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Block Tenders.
Tender For corrigendum : supply of switch board cabinet for lhb eog ac coaches to rdso specn.no.rd so/pe/spec/ac/0184-2015 (rev-1). note: i) mpcb#s for water pumps 1&2, condenser & ventilation fan motors ratings shall be provided as per rdso ltr.no.el/7.1.108/sbc dt.01-05-2023. ii) the compressors , heater circuits wiring shall be provided with 4 sq.mm cable & suitable cage clamp terminalblocks for 4sq.mm cable (block nos. 239-241, 243-245, 259-261, 263-265, 242 & 262). rbc & ebc (s1f160 & s1f 170) circuit wiring shall be provided with 6sq.mm cable and suitable cage clamp terminalblocks (in s1 x3) for 6sq.mm cable. iii) mounting details for rmpu switch panel & stiffeners shall be provided as per drawing no. icf/sk3-7-2-062 alt- a or latest. iv) 8 nos of crimping sockets shall be supplied with discon necting & earthing device as follows. a) for schaltbau make d&e device crimping sockets to drg. no. icf/sk-7-2-166 alt-w, type-d10/38, bend-90 degree. b) for salzer make d&e device crimping sockets t o item-10 of edts-200 (latest). v) note.no-4 in rdso drg.no.rdso/pe/sk/0205-2019 (rev-1) sheet 2 of 16 shall be read as #pg29 suitable end fitting for power & control cables shall be used#. vi) packing in struction: pi-115 ver. 3.0. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminalblocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminalblocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For tender for supply of hrc fuse cylindrical type-4a rdso approved , hrc fuse cylindrical type-6a(rdso approved , hrc fuse cylindrical type-10a rdso approved , hrc fuse bs88 gg , offset blade type-10a rdso approved , glass fuses 315ma , glass fuses 630ma , glass fuses 2a , glass fuses 4a , glass fuses 6a , glass fuses 10a , glass fuses 16a , rj45 connector , rj45 connector shielded , cat6 cable , digital low current clamp meter to measure current leaks parasitic draw down to 1 ma and electric loads from 1ma to 100 amp ac/dc , voltages from 0 to 600v ac/dc , small jaw size to measure current in signalling circuit , 4 digit display. make -fluke , gtc/kew , scope or superior with better specification as mentioned with all accessories like test lead , batteries and carrying case , sample may be got approved from consignee before supply. , puf sealant 200ml , lan tester test the correct pin configuration of 10/100 base-t 10 base-2 thin ethernet cable to verify cable continuity , oprn , short and miss wire , lug crimping tool , tagari or ghamela gi , oil pump , chamois leather for cleaning purpose 1 piece of size 600mm x 500mm or 2 piece of size 300mm x 250mm conforming to is 1017 grade 2 , krone tool , silicon sealant 200ml , glass putty of is 419-1967 , wd 40 spray can , rj45 crimping tool , soldering iron soldron make electric wattage 25 watt , silicon sealant applicator gun , door mat 2 feet x 3 feet , digital vernier callipers ( measurement range 0-6 inch , 0-150mm resolution 0.01inch , 0.1mm accuracy plusminus 0.2mm , 0.1 inch) , supply of ara terminalblocks small m6 made of pbt as per specification no irs- s-75-2006 rev. 2 with latest amendment and rdso drg. no. sa-23741a -alt-4 , m22 x 275mm , bolt , nut , 2 washer , 1 spring washer and 1 lock nut , m8 , 2 nut , m30 , 1 nut , 1 check nut and 1 washer , m12 x 100mm , bolt , 4 washer , nut 3 set , csk m6 x 30mm- nut , bolt , spring washer 2 set , m20 , 2 nut , 1 check nut , 1 spring washer , 1 washer , m24 , 2 nut , 1 check nut , 1 spring washer , 1 washer , m22 , check nut , m24 , 1 nut , 1 check nut , 5 by 8 x 2 inch bolt hex , 3 by 8 x 2 inch bolt hex , 3 by 8 x 1.5 inch bolt hex , 3 by 8 x 1 inch bolt hex , 3 by 8 x 0.75 inch bolt hex , square head 3 by 4 x 4.0 inch - 2 washer , 1 spring washer , nut , check nut , locking pin , square head 3 by 4 x 5.5 inch- 2 washer , 1 spring washer , nut , check nut , square head 3 by 4 x 3.5 inch- 2 washer , 1 spring washer , nut , check nut , locking pin , m8 x 40 - 1 nut , 1 spring washer and 1 washer
Tender For supply of mpcb 1.6 a with auxiliary contact (1 no + 1 nc) and terminalblock db, thermal release range 1 - 1.6 amp, voltage rating 415v, class:10, breaking capacity 50 ka, pole:3 p, make -a bb/ schneider/ siemens/ l&t/ c&s only and as per rdso specification no. rdso/pe/spec/ac/0184-20 15 (rev.-0) [ warranty period: 30 months after the date of delivery ]