Web Analytics Made Easy - StatCounter

Terminal Connector Tenders

Get complete information related to latest Terminal Connector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Connector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Connector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39322145 Due date: 10 Mar, 202510 Mar, 2025 NA
Tender For corrigendum : supply of bi-metallic terminal connector for oip bushing for twin acsr moose conductor to drg 34993050007 r- 03

State Government

CTN :39400371 Due date: 09 Mar, 202509 Mar, 2025 25.36 Lacs
Tender For corrigendum : dismantling of existing porcelain lightening arrestors, surge counters, cvts, acsr conductor, supporting porcelain insulators, supporting structures, complete form line side insulator to takeoff tower for 66kv shimoga bhadra lines 1, 66kv shimoga bhadra lines 2 and lh transmission lines.2)2)supply, erection, testing and commissioning of 3 nos. of 66kv transmission line equipments like cvts, polymeric lightening arrestors with surge counters, supporting polymeric insulator stacks, lynx acsr conductor, clamps, connectors, structure etc. complete from line side isolator to take off tower of 66kv transmission line equipments from line side isolator to take off tower at bhadra generating station.3.dismantling of existing 72.5kv, 0.5cl current transformers, supply, erection, testing and commissioning of 0.2 class, 72.5kv current transformers for 12mw river bed units 1 and 2 at bgs.4.supply of essential spare 04 nos. of 66kv polymeric insulator stack and 01 no. of 0.2cl 72.5kv current transformer.5.jungle clearance along the lines wherever necessary.6.the scope also includes testing at works before dispatch, pre-commissioning and commissioning tests at site and the performance guarantee tests in respect of 72.5kv cts, 60kv las, 72.5kv cvts required for bhadra generating station.7.the scope of supply shall include all accessories, marshalling box, terminal connectors, wedges, clamps, supporting structure etc., which are necessary for assembly and erection of ct, cvt & la.8.modifications required for foundation and support structures to erect newly supplied cts, cvts and las shall be carried out by contractor at no extra cost.

Central Government/Public Sector

CTN :39596829 Due date: 20 Mar, 202520 Mar, 2025 NA
Tender For supply of stud type terminal connector,end cover - elmex kps4 or equivalent,end clamp - elmex scusl or equivalent,barrier plate - elmex kbxf or equivalent

Central Government/Public Sector

CTN :39572503 Due date: 20 Mar, 202520 Mar, 2025 5.76 Lacs
Tender For supply of terminal connector on la to suit 2 acsr moose c1 , terminal connector on bpi to suit 4.5 ips al tube c5 , terminal connector expansion type on cb to suit 4.5 ips al tube , terminal connector expansion type horizontal take off on iso to suit 4.5 ips al tube c2 , terminal connector horizontal take off on iso to suit 2 htls conductor c2 , terminal connector rigid type horizontal take off on iso to suit 4.5 ips al tube c2 , terminal connector expansion type on ct 3000a to suit 4.5 ips al tube c3 , terminal connector on ct 3000a to suit 2htls conductor c3 , terminal connector on cvt to suit 2acsr moose c4 , terminal connector on emvt to suit 2htls conductor c5 , terminal connector expansion type on cb to suit 4.5 ips al tube c6 , terminal connector on wave trap to suit 2 htls conductor c7 , terminal connector on bpi to suit 2acsr moose c8 , tee clamp to suit 2htls to 2 htls conductor t1 , tee clamp to suit 2htls to 4.5 ips al tube horizontal take off t2 , tee clamp to suit 2htls to 2acsr moose conductor t3 , pg clamp to suit 2acsr moose to 2acsr moose conductor t4 , t clamp for inverted v connector to suit 4.5 ips al tube t2

Central Government And Public Sector

CTN :38919099 Due date: 06 Mar, 202506 Mar, 2025 NA
Tender For bid to ras supply of 3000010646_ 1_ 83002101160-loopin loopout box-ltg pole junction box loop in loop out junction box as per attached technical specificationwith following minimum requirement. frp material of thickness 4mm (min),04 no of ways(min)at bottomwith provisionof cable gland,08 nos(min) terminal connector of1100v grade and supporting cable size:25 sqmm max) (one) and 03nos of 4cx2.5sqmm copper cable.dimension of jb (wxhxd)mm:150x150x75mm. (minimum)overall dimension tolerance ( +in mm): 20 in w xh and 10 in dmaterial of junction box: fibre reinforced plasticdegree of protection: ip65 (as per is/iec 60529:2001 latest)safety compliances: fire retardant and self extinguishing ul-94 5vamaterial (sheet)minimum thickness (in mm): 4type of front cover fixing on junction box (front side): front cover with 4 nos. quarter turn tool operated locking knobs.provision of knock out for cable glands on junction box: yesno. of ways on jb: 4 (bottom side)shape of the jb: rectangular/squarevoltage grade of terminal block: 1100 v (min), 50 hz, ac number of terminal connector on junction box:8 terminal connector supporting for maximum size of conductor (in sq mm):4cx25sqmm al cable insulation resistance> 200 mohmtype of mounting: structural mounting/wall mounting accessories for each junction box: neoprene rubber gasket 1 no.high voltage withstand test (between all live parts connected together and the body):2 kv (rms) for 1 minute availability of test reports withcomplete drawings from central govt lab/nabl/ilacaccredited laboratory to prove conformity of the specification: yestest report number and date : party to furnishname and address of the lab: party to furnishagreed to furnish all the test reports and certificates to the buyer/consignee on demand: yes""all other specifications are as per annexure-1, party to submit theannexure -1 in complete filled up & signed condition failing whichthe offer will be technically rejected"

Central Government/Public Sector

CTN :39549759 Due date: 25 Mar, 202525 Mar, 2025 NA
Tender For supply of expansion type terminal connector to suit 50 dia aluminium tubular bus-bar to terminal pad of 25 kv isolator/ct/cb (ri no. /part no. 11061, 11062, 11063) with fasteners, as per rdso specification ti/ spc/ohe/fitting/0130-10/13-rev-1 & drawing no. eti/psi/p/11060, rev.e or latest. make/brand - core ap proved vendors only. (list attached) [ warranty period: 30 months after the date of delivery ]

corporations/Associations/Others

CTN :39536792 Due date: 14 Mar, 202514 Mar, 2025 NA
Tender For auction sale of ss scrap,empty plastic barrel,empty metallic barrel,truck tyres,miscellaneous vehicle tyres,damaged/ condemned chairs,used batteries,air filter scrap,insulated copper/ aluminum cable scrap,used control panel,electrical scrap,metallic tins 20 l,expired paint,wood scrap,polythene waste,carton box packages,used oil in 210 liters barrel

corporations/Associations/Others

CTN :39408373 Due date: 18 Mar, 202518 Mar, 2025 4.00 Crore
Tender For corrigendum : supply of spare parts of vcbs - shunt closing coil with plunger assembly [aux volt: 110v dc], series & shunt trip coils with plunger assembly & mounting bracket [4 coils = 1 set), shunt trip coil with plunger assembly [aux voltage: 110 v dc], fuse hrc link 10 a, hrc fuse base 32 a, spur gear big, spur gear small, pole assambly (barrier, vacuum interrupter & upper-lower bus bar), epoxy barrier, vacuum interrupter, roof bushing, roof bushing with copper stem & assembly, wiring of trolley, operating mechanism, (spring charged store energy), spring charging motor mechanism,, ammeter selector switch, breaker auxiliary switch [contact: 6 no+ 6 nc] ,, breaker auxiliary switch [contact: 8 no+ 8 nc] ,, voltmeter [type: analog, size: 96x96 sq.mm] (range: 0-15 kv), ammeter (96x96 sq.mm) range: 0-100-200-400/5a, test terminal block rear connection, relay test terminal block, breaker control switch, trivector meter (tvm), ac ht static meter suitable for 3 ph 4 wire unbalanced load [ct ratio: 100-200-400/5a ptr: 11 kv/110 volt], numerical relay 3 o/c & 1 e/f, make _____, current transformer [ratio: 400-200-100/5-5a, stc: 16 ka protection core:5p/15 va, metering core: 0.5s/15 va], indoor single phase resin cast potential transformer, ratio: 11 kv/110 volt, burden: 100 va,, pt primary fuse [ rating: 11kv, 3.15 amp,, jaw contact / disconnecting contact [ ratio: 630 amp & above], charging link with assembly for bb1-3, epoxy post insulator, wiring of trolley , type:rb1-3, power factor meter, shunt trip coil with plunger assembly, aux voltage: 110 vdc, bridge rectifier, power pack 100watt ,110vdc, upper terminal-l type, middle terminal-l type, earthing bus bar l type [50x6 mm copper], copper flexible bus bar, pt jumper, middle terminal-pad, top terminal pad, limit switch/micro switch, toggle switch, door switch, 32 pin plug socket, push button-black shroud, local-remote switch, terminal connector, indication lamp, antipumping relay, heater, thermostate, labour charges per breaker for inspection & fixing of required spare parts to put defective breaker in operating condition

Central Government/Public Sector

CTN :38851671 Due date: 05 Mar, 202505 Mar, 2025 NA
Tender For bid to ras corrigendum : supply of surge arresters and accessories - locations as mentioned in scope of work in annex-01 , 216 kv surge arrester for wr-i at various locations as mentioned in scope of work in annex-01 , 216 kv surge arrester for nr- ii at various locations as mentioned in scope of work in annex-01 , 216 kv surge arrester for sr-ii at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for nr-i gr-1 at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for nr-i gr-2 at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for nr-iii at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for wr-i at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for kotra ps as mentioned in scope of work in annex-01 , 120 kv surge arrester for wr-i at various locations as mentioned in scope of work in annex-01 , 120 kv surge arrester for nr-iii at various locations as mentioned in scope of work in annex-01 , 120 kv surge arrester for nr-i gr-1 at various locations as mentioned in scope of work in annex-01 , 60 kv surge arrester for nr-i gr-2 at various locations as mentioned in scope of work in annex-01 , 624 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 390 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for ner at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for sr-ii at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for wr-ii at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for ner at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for sr-ii at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for wr-ii at various locations as mentioned in scope of work in annex-01 , 132 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 120 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , surge monitor for sr-ii at various locations as mentioned in scope of work in annex-01

CTN :39380825 Due date: 15 Mar, 202515 Mar, 2025 NA
Tender For corrigendum : procurement of several types of terminal connectors for uses in retrofitted new 245kv, 2000a isolators of unit-7 220kv sy
 Loading, Please wait...

Connect us via What's Up