Tender For supply of pneumatic control valve boq - globe control valve size 40 mm , spare aluminium diaphragm plate for 40 mm valve , spare actuator spring set for 40 mm valve , spare rubber diaphragm for 40 mm valve , globe control valve, size 25 mm , spare aluminium diaphragm plate for 25 mm valve , spare actuator spring set for 25 mm valve , spare rubber diaphragm for 25 mm valve
Tender For supply of 300nb pneumatic globe control valve , diaphragm for pneumatic globe ctrl valve , retainer ring pneumatic globe ctrl valve , seal ring for pneumatic globe ctrl valve , gasket for pneumatic globe ctrl valve , gland packing pneumatic globe ctrl valve , smart positioner for pneu globe ctrl val , position feedback transmitter , seal kit for the positioner , actuator seal kit for pne globe ctrl val , cage for pneumatic globe ctrl valve , plug for pneumatic globe ctrl valve , stem for pneumatic globe ctrl valve , seat for pneumatic globe ctrl valve , complete set of solenoid valve , solenoid coil
Tender For corrigendum : design, engineering, manufacturing, procurement of materials and bought out components, assembly at shop, testing at manufacturer works, inspection by tpia, packing, supply of control valve (globe) as per material requisition
Tender For tender for supply of union nut 7 16 unf part nopoint 05528 , pressure regulator oil cplpoint part , cathode protector for condenser of 4 tr ref plant for nopv , angle valve 1 2 , safety relpointvalve 1 2 npt m x3 4 npt m set prespoint12point5kg cm2 r , charging valve , three way valve 1 4 , vibration eliminator for liquid injection , sw temp gauges , oil filter , suction shut off valve , internal oil filter element , piston ring set glyd ring , capacity control solenoid valve , motor projection int69 tm , motor replacement gasket & o ring set , woodruff key a10x16 part nopoint05673 , cylinder screw m8x25 part nopoint 06330 , set shaft seal part nopoint08444 , set gaskets part nopoint 08492 , base plate gasket part nopoint 05100 , seal ring 27 8x24 2x2 part nopoint 05791 , seal ring 27x22x2 part nopoint 05342 , pressure spring for oil filter part nopoint , o ring diapoint82 22x2 62 part nopoint , locking screw m22x1 5 part nopoint 06348 , sealing cap 7 16 unf part nopoint 05545 , core for filter drier , safety valve , charging valve , valve angle type 3 4 npt m x 3 4 flare , valve globe type 7 8 ods , vibration eliminator 7 8 ods , vibration eliminator for liquid line , fabricated frame , bearing ball , suction pressure switch , discharge pressure switch , pressure transducer , temperature transducer , pilot operated solenoid valve , piolpointoperpoint solenoid valve sporlan type 180s with 230v ac coi , compressor discharge pressure switch , coil for pilot operated solenoid valve , compressure suction pressure gauge , water seawater line differential pressure gauge cum switch , compressor suction temp gauge , percentage meter , contactor 24 vdc 2no 2nc siemens 3th2022 0bb4 , hooter apex 230v ac , ac ammeter ae rishabh 0 300 900 amps 300 5 , tong tester
Tender For tender for supply of internal oil filter element , vibration eliminator flexible connection suction line , no element siemens 3tx4 010 2a , compressor oil heater , teflon seat washer 5/8inch , set of v belts , set of gaskets for condenser for 4 tr ref plant for nopv , ac voltmeter 0 to 500 vac 1.5 class rishabh type pq72 , thermosatatic expansion valve danfoss teat 20 20 , motor terminal plastic insulators , teflon seat washer 2-1/8inch , filter drier core for liquid injection line. , thermostatic expansion valve , size-3/8inch x 1/2inch flare , core for filter drier , hrc fuse link 4a , oil seal kit (mechanical seal ) for xrvn-127r4/165/26 , gasket set for condenser , kit for power contactor , valve angle type 1/4inch npt , tube steel o/d 8x1 thkx0.5m l , locking screw 1/8inch nptf part no. 05514 , compressor bock open reciprocating f14/1366bi r22 1000 rpm , tapered compr.ring 80x2 chr. part no 06367 , compressor suction pressure switch , condenser for 20 tr r22 ac plant for ekm submarine , locking screw 1/8inch nptf part no 05514 , seal plug 1/4inch nptf part no 05801 , selector switch salzer l&t 6a 250 v 2 p on/off , bearing front (nu216) , bearing rear (nup 216) , set shaft seal part no08012 , compressor discharge temp gauge , pressure gauge 65 dial -1 to 15 kg/cm2 for r134a , core for filter drier , aux contactor ge rl4r 4no coil-24v dc , solenoid valve danfoss evra15-24 v dc coil , push button siemens e-22 1 no+1 nc (red) , push button siemens e-22 1 no+1 nc (green) , allen bolt for nde inner bearing cover fixing part no.0051 , allen bolt for de inner bearing cover fixing part no.0050 , core for filter drier sporlan rp48bd , oil heater 1 kw with thermostat for 82.5 tr ac plant , semi conductor fuse m300115c 6.9 urd 30 d08 a0315 , cartridge for indufil duplex oil filter idgl-2-220 , water/seawater line differential pressure gauge cum switch , refrigerant line muffler plping and accessories of 144tr ac , shaft seal placement kit part no.kxs204 , cable gland size 4 , rhb/lht pre-load spring washer , vibration eliminator for discharge line , cable gland size 2 , star locating pin , cable gland size 6 , safety valve , control transformer tape wound 415 v/110 v 150 va , core for filter drier sporlan rc4864 , set of bearing for 7.5 kw motor for 2x2.1 tr ref plant , set of bearing for 1.5 kw motor for 2x2.1 tr ref plant , vibration eliminator 1-3/8inch ods , thermostatic expansion valve gfe-1zp charge 1/4inch x 1/2inch flar , valve check type 5/8inch ods , valve globe type 7/8inch ods , temp switch danfoss rt34-25 to 15 deg c , set of gaskets for condenser for 2 x 2.1 tr ref plant , set oilsump heat 80w 220-240v part no.08425 , set oil pump part no 08044 , set shaft seal part no 08008 , cw pressure gauges range 0 to 10 kg/cm 2 g , condenser , hrc fuses 100 amps , contactor 200 amps , push buttons , angle needle valve 1/4inch , level switch , compressor gauge , bolt hex head , hrc fuses for soft starter , screw driver 12inch , continuity tester , gasket set for condensor , temp switch , pressure switch xml a 0037 , lock nut m 120x2 km24 , ferrule id 10 steel , ferrule id8 steel , thermometer with brass shield 1/2inch bsp , rubber bonded washer , gasket , gasket , gasket , seal kit for filter assly , hooter ems0001016 24 v dc , aux contact ge rl4rd040td 5no coil 24v dc , bearing de nu 220 for 160 kw motor elmot , semi conductor fuses ge / feraaz 200a , 6.611 rd30-xx0315 , mc mccb ge 100a s 400a , with aux contact 2no+2nc , star contactor 415v ac with 1no+1nc coil voltage 110v ac , mc mccb ge 3pole 200a 415v ac s 2ka mc401 , catridge for indufil duplex oil filter model idgl-2-226 , emergency push button red 1no+1nc , lamp 380v ac red for lcp(siemens) , flexible gas charging line , megger , tong tester , gauge adopter 1/8inch fptx1/4inch sae , insulated screw driver 3inch , lube oil differential pressure switch , mccb siemens 3 pole type 3vl 3720-1dc36-0aa0-200a(55 ka) , teflon seat washer 1-5/8inch
Tender For custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if required., oil le