Get complete information related to latest Timer Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Timer Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Timer Panel Tenders.
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For construction of cc road from lagudu appala naidu house (digital door no. 105) to guard appala naidu house (digital door no. 149) in gatchapu veedhi in ward no 28 of narsipatnam municipality (1st call)
Tender For repair/maint of lt panels, gate lights, gi octagonal polles, st light timerpanels, mini mast, solar lights alongwith connected items in cantt area under ge (i) kanpur
Tender For tender for supply of supply and installation as per demand - foundation 2 cmt , gi octagonal pole 5 mtr , 4 mm armoured cable , dp mcb 32 amp , gi foundation bolts , single arm street light bracket , 36w street lights , 2 core pvc insulated wire 2.5 sqmm cable , controller timerpanel , solar street light 30w , lithium lifepo4 battery 36ah , solar panel 165w , gi 3 inch pipe (per 6 meter) , earthing pipe b grade gi pipe
Tender For supply of unit insignia , digital wall clock , pedestal fan , fly catcher , window ac stand , green net cloth , flood light led , unit logo bd , tree guard iron
Tender For tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes refractometer,