Tender For supply of panel display unit comma 40 kva genr set , alternator assy comma 40 kva genr set , fuel filter secondary comma 40 kva genr set , mccb comma 40 kva genr set , avr 40 kva genr set , oil pressure sensor comma 40 kva genr set
Tender For amtc of ephs sector 32 and 34 ue ambala cantt. repair of 25 hp submersible motor pump mccb panel board and cable at various tubewell complete in all respect and all other contingent thereto
Tender For corrigendum : advance e-tenders are invited for material required for smooth running of t/wells under 91 no,25no,23no, 1 no out of 19 no and 41 no. scheme under 502 no deep t/well scheme of nawanshahar pwrmdc ltd.,sub division of distt. sbs nagar under bdc-1 division, ropar - bch make 110 amp duros freedom series 3 pole ac control contactor size -g cat no bch15mt-3-11, bch make spare magnetic coil size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make ct operated overload relay range 37.6-60.0 amp cat no ct2 mc305ana3c, bch make ct operated overload relay range 56.4-90.0 amp cat no ct3mc305ana3c, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type ml-6 size fr-3cat no ss90921, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 180 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type ml-6 cat no 5595313, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, spare coil ml6 125amp, l&t make thermal overload relay type mn5 range 45-75 amp cat no ss9413700, l&t make thermal overload relay type mn5 range 66-110 amp cat no ss9413700k0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, kitkat 500 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 25mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 16mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 19/16mm, al thimble, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, shunt capacitor with clamp l&t make 25 kvar, push button l&t red, yellow, green, blue, overload relay l&t 40-80 amp, overload relay l&t 20-60 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 30 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, ct voltmeter + ammeter combined, terminal block 100 amp 3 way l&t, pvc wire 7/64, controlpanel l&t make 50 hp, controlpanel l&t make 75 hp, boparai basp-0708a single phase preventer
Tender For supply and installation of electrical and mechanical equipment of tubewell at road no.66 jafrabafad and shastri park tubewell. (re-invite) - supply and installation of electrical and mechanical equipment of tubewell at road no.66 jafrabafad & shastri park tubewell by carrying out following works:- dismantling/lifting of tubewells with the help of gas cutter and heavy manual labour., supply of pvc insulated sheathed copper conductor cable for submersible pump motor of size 6mmsqx3core make :- finolex/ havells/ grandlay/djb approved make, supply of 80 mm dia d/f g.i pipe in b class as per isi 3 mtr long complete with cutting flange for submersible cable and support welded. make :- jindal/ tata., supply of tail piece medium class 0.5 mtr long including one end flanged and other end threaded of 80 mm dia., supply of 80 mm dia g.i bend with both side flanged welded, s/o m.s. clamp of m.s. strip 8mm thick duly hole for holding the pipe of 80 mm dia with nut bolt and washer, s/o m.s bore cover made out of m.s. plate suitable for 12" dia bore complete with suitable hole for pssing the 80mm dia gi pipe., s/o ci, d/f swing type nrv of 80mm dia make:- kirloskar/ ivc/djb approved make., s/o electronic dozing pump (4lph,5.5 kg) electrically controlled operated 230v, 50 hz, supply chemical grade tank of 100 ltrs with pipe make- milton roy/clomax, s/o nut bolts with washer of good quality of 1/2"x2" size, s/o rubber packing sheet synthetic 50% make :- jyoti / national, lighting arrangement including providing fixing1 no. tube light fitting 40 watt, 1 no. bulb point, 1 no. flood light on wall of room and also control board.etc.i/c electrification of room., labour charges for lowering the submersible pump set with all allied e&m equipments and fixing delivery line, valves, electronic dozing pump i/c hardware items as nut, bolts & washer i/c cartage to & fro., lt panel work of tubewell in road no.66 jafrabafad & shastri park tubewell:- dismantling of lt panel with allied equipment with the help of skilled labour., s/o power contactor 32 a. triple pole. make l &t/ havells, s/o front mounting add on aux contact block. make : havells/l&t, s/o three pole power contractor -25a cap. make l&t/ havells, s/o ampare meter (0-30a) 4 size squ. type. make l&t/ae, s/o voltmeter (0-500v) 4 size squ. type. make ae/l&t, s/o indicating lamp set for ryb phase. make l &t/ havells, s/o single phase preventor. make l&t/ minilac, s/o timer switch digital/anolog type. make l&t / havells, s/o over load relay thermal type 14-23 a. make l &t/ havells, s/o star delta timer on delay. make l&t /havells, s/o sp mcb 6a. make : l&t/havells, s/o 3p mcb 63. make : l&t/havells, push button 22.5mm(red / green), s/o 4p 63 amp elcb make : l&t/havells, changeover switch 63 amp., s/o 100a 3p mccb 25ka. with spreader make : havells/l&t., s/o rubber mat for electrical purpose of size 1mx2m and 3mm thick. make:- jyoti/ national, labour charges for repairing of lt panel with installation of above components i/c electric connection , testing and commissioning on load.
Tender For supply of automatic star delta starter panel in 16 swg steel sheet enclosure of size 600x750x200 mm,three phase 415 v, ac, load current 70 amp, 50 c/s, 40 hp, light gray spray painted, panel wiring of powersection with 1x35 sq mm multi stranded pvc insulated copper conductor 1.1 kv grade, comprising of - 01 no hlvd2 voltage sensing relay, 01 no, qt-100 time switch, 01 no hour meter, 01 set phase sequence indicator, 6-way connector, 01 no toggle switch 15 amps, 01 no ammeter (0-200a), 01 no voltmeter (0-600v),01 set ct coil 100/5 & 15va, 03 nos led indication lamps, 01 no selector switch (ass), 01 no selector switch (vss), 03 nos cut out 6a for control, 03 nos toggle switch 6a for control, 2 set green/red push button for on/off, 01 no kwh meter type ct 2m - 200/5 ct operated, 03 nos ml- 4 contractor with 2no & 2nc, 1 no bi-metallic over load relay (40-70a) type mn x r4, 01 no electronic timer (0-30 sec), 01 no motor protection relay, 01 no mccb type dh- 200/35ka, 01 no time delay relay (0-30 minute). make- l&t, c&s and abb or similar [ warranty period: 30 months after the date of delivery ]
Tender For repair maint of lt switch gear, mccb, change over switch, lt panel, lt cable alongwith connected items in map afmsd area and repair replacement of submain wiring, mccb db, vtpn, earthing and connected items at other than basistha under ge guwahat
Tender For corrigendum : tender for supply of clip on type terminal station , auto change over switch 250a , cam type single pole on-off switch 10amps , 1s160 , triple pole moulded case circuit breaker 100amps , hcos 100a for emergency operation(ex.)if envisaged in sotr , illuminated push button green , cam type selector switch 2p 2 way with off 10a , hrc fuse link rated 100a , fuse link 2amps , helo starting cable with nato end connectors (21 meters) , mccb 630a , type lm 630b , make e , 3 pole mccb 32a -nsx100f , mcb 250a with micrologic 2.2 trip unit(lv431770) , tp mccb rated 50a , single pole nine way without off rotary switch rated 16a , contactor 110a t.p.(contact kit) , aux contact.base block ( 1 no+1nc) for 110-a t.p. , fuse 32a fitting hrc , unshourded pushbutton 1no+1nc with yellow colour lens(pmt1ab , illuminated pushbutton integral led 230v red , add on 1no contact , d.p miniature circuit breaker rated 16a , terminal , conventional fire detection panel 4 zones , on delay electronic timer ac 110-240v having range 1-30s , 230v ac relays 4 c/o with led and base alonwith clamp , tp mcb 63a(c60h 3p 63a c) , ammeter 0-1000a , rm-800a , ctr 1000/5a , 96x96 cl1 acc 900 scale , hrc fuse fittings rated 20a (3nw20nnsf) , hrc fuse link rated 6a(3nwns6) , hrc fuse fitting rated 20a (3nwns10) , insulation monitoring relay 115v 3ph 400hz (vtv-02) , ammeter 0-200a ctr 200-5a , 400hz acc cl-1 , 96x96 rm at 150a , kilowatt meter 120-0-750 kw size 96x96mm , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , 1 watt , 24v dc/ac , led bulb , milky white of e27 thread type , 1 watt , 230v ac , led bulb , milky white , of e27 thread type. , breaker 25a , dp mcb , step down transformer 20kva , 380 230v , 3ph , 50 hz star-delta , smoke detector tester gas bottle - solo , main processor unit , navigation lamp 65w 230v (per yard) , under voltage coil 230 , 50/60 hz , hrc fuse fitting with fuse link rated 4amps , hrc fuse fitting with fuse link rated 2a , 3 pole mccb , 100amps , 36ka , schinder make , phase sequence indicator 50-500v , 96x96mm cl1 acc 900 scale , kw mtr 15-0-150kw , ctr 2005/5a , rm at 80kw , 415v , 3p , 2 ele 96mm , generator protection unit415v , 3ph , 50hz , load sharing unit mv av 380v , 50hz , 3ph , ctr 250 5a , m340-discrete outputs-modicon m340 discrete dc output , indicating lamp integral led white colour , 24v ac/dc , indicating lamp integral led green colour , 24v ac/dc , indicating lamp integral led green colour 230v , contactor 800a dc , 28v coil with 1no/1nc aux. contact
Tender For comprehensive maintenance and serviceing of 33 kv switch gears power transformercontrolpanels, relays maintenance and servicing of 11 kv ht switch gears repair and maintenance of distribution transformer ht ug distribution system at mandovi