Web Analytics Made Easy - StatCounter

Transformer Oil Centrifuging Tenders

Get complete information related to latest Transformer Oil Centrifuging Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transformer Oil Centrifuging Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transformer Oil Centrifuging Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :39770206 Due date: 28 Mar, 202528 Mar, 2025 1.27 Crore
Tender For dismantling of old ht panel, 2 nos of oil type transformers and supply, installation, testing and commissioning of new ht panel, 1000 kva dry- type transformer, cable laying and earthing works

State Government

CTN :39760670 Due date: 24 Mar, 202524 Mar, 2025 NA
Tender For supply and installation of split air conditioners to the nemly contructed transformer oil testing lab and hostel building at cetd campus

State Government

CTN :39780546 Due date: 28 Mar, 202528 Mar, 2025 3.54 Lacs
Tender For emd - service charges for testing of the transformer oil samples to carry out the characteristic tests from 01.04.2025 to 31.03.2026

CTN :39713820 Due date: 21 Mar, 202521 Mar, 2025 54.8 Thousand
Tender For dehydration &amp filtration of transformer oil of old 132/33kv, 20/25mva, power transformer at 132 kv gss ghatol, distt. banswara alongwith man power &amp high vacuum filter machine and oil testing kit having100 kv capacity

State Government

CTN :39765620 Due date: 07 Apr, 202507 Apr, 2025 NA
Tender For supply and delivery of one no. automatic oil insulation test set for testing of transformer oil di-electric strength (bdv) for zonal testing unit under zonal office siliguri, power house campus, 2nd mile, sevoke road, siliguri. ( 2nd call )

CTN :39728050 Due date: 21 Mar, 202521 Mar, 2025 5.15 Lacs
Tender For running and maintenance of specialized services of electrical and mechanical equipment like dg set, sub station etc. at drugs testing laboratory mumbai.subwork/packages:repairing, overhauling servicing of 800 kva oil transformer, 11 kv vcb and electric work

State Government

CTN :39476538 Due date: 24 Mar, 202524 Mar, 2025 47.3 Thousand
Tender For corrigendum : testing of oltc transformer oil of various transformer of 400 and 132 kv sub stations

CTN :39646562 Due date: 24 Mar, 202524 Mar, 2025 53.6 Thousand
Tender For corrigendum : dehydration & filtration of transformer oil of 132/33 kv, 31.5 mva power transformer, make- atlanta at 132 kv gss ghatiyawali (dist. chittorgarh) along with man power & high vacuum filter machine and oil testing kit having 100 kv capacity

CTN :39372369 Due date: 22 Mar, 202522 Mar, 2025 10.00 Lacs
Tender For corrigendum : annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacemen

State Government

CTN :39416092 Due date: 24 Mar, 202524 Mar, 2025 51.99 Lacs
Tender For corrigendum : 1)supply of two nos. of out door type 750kva, 11kv/400v, onan auxiliary transformer along with oil as per site requirement 2)supply of lt copper power cable 400v, 1.1kv grade pvc armored 3.5 core 2rx 400 sqmmm along with lv cable termination accessories,lugs etc 3)dismantling of existing 2 nos. of 750kva auxiliary transformers and old oil cooled cables at ltac panel and auxiliary transformer end and its accessories 4) laying of lt copper power cables and termination of cables along with supply of all accessories for laying of cables 5)erection, cabling, testing and commissioning of 2 nos. of 750kva,11kv/400v auxiliary transformers 6)buy back of released two nos. of 750kva auxiliary transformers along with oil
 Loading, Please wait...

Connect us via What's Up