Get complete information related to latest Transit Case Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transit Case Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transit Case Tenders.
Tender For supply of - motor point machine for railway yard trs- motor point machine for railway yard trs description of materials and execution for installation, wiring & testing to operate the point machine at nalco rly yard as per eco.railway sepcfification. 1. supply of electric point operating machine 143mm non trailable to operate on 110v dc complete with lock detector, point junction box along with telescopic pipe and slides for lock and detector- rotary locking. universal type as per specification no: irs/s/24/2002 with latest amendment and drg. no.: rdso/s: 10800 (foc motor) along with standard tool kit set for every 4 point machines. (1no.) 2. supply of ground connection set complete suitable for rotary locking type irs electric point machine as per drg. no. s-3262 for 60kg rail with insulating materials with insulation materials. (1 set) 3. supply of junction boxes with covers and terminal plates 24/30 way to suit drg. no. 236967/1 (as amended up to date) and irs: s-10/78. this includes supply of pbt terminal. (1 nso.) 4. transportation, installation of point machine on ms plate fixed on wooden/psc/steel sleeper complete with fixing of anti-theft arrangement, "d" bracket, junction boxes, connection including smithy works involved for ground connection, including riveting/welding of angle cleats, termination of cables. preliminary adjustment for operation of points by crank handle oiling, greasing, painting and lettering as required. this also includes supply and fixing telescopic arrangement using gi pipes of required dia for provision of wires from junction box to point machine.(1 no.) 5. wiring and testing of electric point machine as per the wiring diagram supplied by the railway. this also includes the connection of electric point machine and fixing of insulation materials and providing two numbers of seven lever ( 7 lever) goderj locks with three keys each, per machine for outside cover, fixing arrangement of crank handle interlocking in point machine, and fixing of e type lock ( if required).(1nos.) 6. supply of steel apparatus case large size as per drg. no.- con/sk/1/186/ and spec no irs:s-10/78 (adv) with latest amend. with "e" type lock & key of ward no.-32 with handle. (1 nos.) 7. transportation, excavation of pit, casting of foundation, plastering and erection of steel apparatus case (full) with fixing of e-type lock, wiring, cable entry, termination, clamping filling cable pit with sand, painting and lettering etc., as per drg no. s & t/con/sk/16. this included earth work and/or masonry work required for securing the apparatus case as per site condition including supply of all required materials wire coils 6 way terminal pbt hylam sheet, wooden plank etc. (1 no.) 8. pvc insulated amoured, unscreened, underground railway signaling cable as per specification no. irs:s63/2014(rev.4.0) 12/core (250 mtrs) 9. excavation of trenches of depth 1.0m including clearing of roots and trees etc. for all types of soil. this work also including covering of cables laid in trench and backfilling, ranning and consolidation of soil as well as disposal of extra soil after cable is laid as specified in guidelines on signaling cable laying given by rdso and any latest circular.(100 mrtrs) 10. track crossing by horizontal boring method as per technical specification of manual as per feasibility of site condition including supply of dwc pipe or hdpe pipes. (18 mrts) 11. laying of signaling cable/power cable to extend the power of all sizes in excavated trench, etc. (0.5 km) 12. supply, transportation, installation, testing and commissioning of earth electrode, construction of cement enclosure to drg. no. con/sk/t/9a and drawl of 6 swg wire or 2 nos. of 8 swg wires from each electrode to place advised by the site engineer including fixing and soldering of lugs and measuring, painting of the earth resistance etc. (1 nos.) 13. supply of smr ower panel (minl ips) having smr module03 nos., dca card01, dc-dc convertor 24-32v/10amps-
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
Tender For tender for supply of non expendable medical stores - table instrument , folding light ss with two ss shelves complete , table operating , folding , light weight version , table steriliser marble topped 91cm x 61cm without wheel complete , wheel chair non folding institutional model complete , apparatus oxygen inhalation protable filling adapter for refilling empty oxygen pin , cylinder oxygen o2 340 ltr with pin index non interchangeable flush type valve painted black , lighted intubation stylet small medium large , mouth prop and airways aluminium set of 3 complete , apparatus suction foot action purves spare , forceps , artery , straight , box joint 13 cm , forceps towel holding , instruments regimental medical pannier roll of complete , knife bard parker handle size 1 fitting commercial no. 3 for use with commercial blade no 10 11 12 and 15 , percussor babinski , probe silver 25cm , proctoscopeself illuminating with transformer , noiseless suction machine , atomiser nose and throat complete , diagnostic set ent with fibreoptic light illumination halogen lamp complete , lamp examination with eye condenser complete , probe aural or nasal 14 cm set of 6 , reflector with fibre black light canvas forehead band complete , syringe ear metal 114 ml with wide nozzle , ophthalmoscope direct , bottle hot water ir 30 cm x 20 cm with two spare washers , finger check electronic digital blood pressure recorder , irrigation 2 litres with wound pipe and clip complete , jar ss circular with cover 20 cm x20 cm , scales baby weighing spring type with strong wicker basket to weigh up to 10 kg complete , haemometer for haemoglobin estimation by acid haematin method with fade proof prismatic colour plates with square round comparison tubes in calico covered case with velvet lining , apparatus chloroscope neeri model for estimation of residual chlorine in potable water complete. , apparatus water testing horrocks complete , apparatus mosquito catching complete , emergency kit medical officers 1998 pattern complete , emergency kit para medical staff 1998 pattern complete , scoop stretcher , apparatus resuscitator lung automatic complete with o2 cylinder 340 ltr capacity tubging connection face mask flow meter and ventilating unit , cylinder oxygen o2 340 ltr with pin index non interchangeable flush type valve painted black with white valve end empty for , cylinder flush type key spanner for , emergency kit medical officers 1998 pattern complete components as under