Get complete information related to latest Transmission Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transmission Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transmission Pole Tenders.
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For tender for supply of taking down of light fittings of any type size and model complete all as specified and directed. , taking down of brackets of any type size and model complete all as specified and directed. , m& l in repair steel tubular swaged poles complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 sp 22 (8.5 metres long) complete all as specified & directed. , m& l in repair steel tubular swaged poles complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 sp 31 (9 metres long) complete all as specified & directed. , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , supply and fixing in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics , efficacy 110/120 lpw , complete with ip 65/66 protection complete all as specified and directed. , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , with impact and corrosion resistant complete with driver and lamp , efficacy 110/120 lpw , including clamp , nut , bolts etc.complete all as specified and directed.make. crompton , cat no.lfl 80 cdl/60 hpm , supply and fixing in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , with impact and corrosion resistant complete with driver and lamp , efficacy 110/120 lpw , including clamp , nut , bolts etc.complete all as specified and directed.make. crompton , cat no.lfln 150 cdl/60 m , s&f cable junction box 155x210x92 mm in size , made out of thermoplastic , having ip 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 nos polymide gland with check nut (m 32 02 no & m 25 01 no) fixed on poles with aluminium clamps of size 25x3mm , nuts , bolts , washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. make. cat no. dk 1616g of hensel or equivalent model , supply and passing through steel tubler pole/service connection , 1100 volts grade multicore , fr , round insulated copper conductor and sheathed flexible cable , multistranded , three core of nominal cross sectonal area 1.5 sq mm , for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. , s and f single arm bracket made of40mm dia 1.0mtrs long for security light , with mounting ms clamp of flat iron size 25x5mm of suitable length 02 pairs including nut bolt etc of suitable size and painting to ms clamp with two coats of aluminium paints over a coat of red oxide netal primer all as specified and directed by engr in charge. , s & f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees , bends , elbows , reducers , bell mouth tube ends and fixing accessories such as couplers , lock nuts , saddles , pipe hooks , clamps etc. all as specified and directed by engr in charge. , m and l for earthing complete with ms galvanised plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less tan 2.25mtrs deep below ground level with top edge of the plate not less tan 1.5mtrs below normal ground level connected to galvaniosed iron strip 32x6mm as earthing lead by means of bolts nut check nut and washers of galvanised iron welding or steel all as shown in electrical plate no 3 in ssr part i of 2009 connected to earthing test point all as specified complete with exevation and earth work pcc pit with 6mm thick ci ms cover having suitable handle 10mm ms rod with frame and locki
Tender For corrigendum : supply of various spares for ushp-i, sumbal-carbon brushes for slip ring (as per sample)11 kv cable jointing kit 120-185 mm211 kv cable jointing kit 400-500 mmm2hrc fuses 32 amphrc fuses 36 amphrc fuses 63 amphrc fuses 100 ampturbine guide bearings chamber ss studs of sizes (as per sample)s s stud for top cover, 24 mm ( as per sample)s s stud for top cover, 22 mm ( as per sample)lock pin for gv (as per sample)accentric/ concentric pins (as per sample)cup seal (as per sample)o-ring of sizes (as per sample)gland seal (as per sample)ferrobustus bush for guide vane top/ bottom ( as per sample)cherwran packing (7 pc/ set) (as per sample)rubber hose pipe 1.5 inches110v contactor (as per sample)brushes for olg motor (as per sample)gop coupling (as per sample)mechanical seal for gop motor (as per sample)gaskit for gop (as per sample)steel wire of governor panel with pully (complete as per sample)hose pipe for servo motor of miv (as per sample)high pressure water rugulating valve 4" (sluice type with flange )mccb 100 a,3, 415 v (as per sample)mccb 63 a,3, 415 v (as per sample)mcb 25a /32a (as per sample)hrc fuse 100 a (as per sample)11 kv drop out/ fuse set (heavy duty)11kv lightening arrestor, line type(heavy duty)"11kv go, ab switch 3-phase, 3-pole, 200 amp, vertical type"isolator for 33kv with earthing bladela set for 33 kv33 kv 10kn polymer post insulator 36kv,170kv impulse, creepage distance, 1224m11 kv link set plumber block (as per sample)air brake contactor of 32 a (as per sample)air brake contactor of 63 a (as per sample)air brake contactor of 100 a (as per sample)steel rope 13mmalmunium step ladder extendable 40 ft
Tender For annual tender 2025-2026 supply of electrical goods in the year 2025-26 in nanguneri town panchayat - 4 feet flourescent tube light, 40w copper choke, 40w tube light starter, 36w / 40w tubelight electronic choke, tube light side lock holder, insluation gum tape roll - isi, 1/18 vir copper wire [1/44] [90mtr], 3/20 cts copper wire [3/36] [90mtr], 7/20 cts copper wire [7/34] [90mtr], 7/16 cts copper wire [7/67] [90mtr], 19/16 cts copper wire [19/51] [90mtr], 1.5 sq.mm 3 core copper cable, 2.5 sq.mm 3 core copper cable, 4 sq.mm 3 core copper cable, 6 sq.mm 3 core copper cable, 10 sq.mm 3 core copper cable, 16 sq.mm 3 core copper cable, 36w 4pin lamp holder, 36w lamp clip, 24w t5 holder, led fitting top protection glass - street light, led fitting top protection glass - flood light, 20 / 25 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 32 / 40 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 6amps to 32 amps sp mcb, 40amps 2pole isolator, 63amps 4pole isolator, 32a d.p switch, mcb box, fuse unit 16 amps 240v, fuse unit 32 amps 415v, fuse unit 63 amps 415v, fuse unit 100 amps 415v (heavy duty), fuse unit 200 amps 415v (heavy duty), fuse unit 300 amps 415v (heavy duty), fuse unit 400 amps 415v (heavy duty), fuse unit 500 amps 415v (heavy duty), main switches spn 32 amps, main switches tpn 32 amps, main switches tpn 63 amps, main switches tpn 100 amps, main switches tpn 315 amps, 63a 4pmc changeover switch, 100a 4pmc changeover switch, automatic on/off street light timer switch with 24hrs 7 days programable digital timer clock, 40 amps 4 pole contactor with coil, mcb switch and connector fully wired with all accessories, street light meter/main box with wooden board, main switch, fuse carrier fully wired with all accessories, electronic 7 days 24 hrs programable ditial timer clock, 63 amps 4 pole contact with coil, 220v - 250v contactor coil, power capacitor, 9w led bulb, 15w led bulb, 30w led lamp, 24w t5 power saver lamp, 2x24w t5 power saver choke, 36w 4 pin non retrofit type cfl power saver lamp, 36w 4 pin non retrofit type cfl power saver choke, 20w high bright led 4 feet light, 20w led power saver street light fitting, 25w led power saver street light fitting, 30w led power saver street light fitting, 36w led power saver street light fitting, 50w led power saver street light fitting, 60w led power saver street light fitting, 80w led power saver street light fitting, 120w led power saver street light fitting, 150w led power saver street light fitting, 100w led power saver flood light fittings, 150w led power saver flood light fittings, 200w led power saver flood light fittings, 40w all-in-one solar led street light fittings, 60w all-in-one solar led street light fittings, 80w all-in-one solar led street light fittings, 18w to 25w led chip board, 30w to 36w led chip board, 45w to 60w led chip board, 72w to 90w led chip board, 120w to 200w led chip board, 18w to 25w led heavy duty electronic driver, 30w to 36w led heavy duty electronic driver, 45w to 60w led heavy duty electronic driver, 72w to 90w led heavy duty electronic driver, 120w to 200w led heavy duty electronic driver, 10 kv surge protector, 48` ceiling fan with all accessories, d.o.l motor starter up-to 10 hp, 10metre hot dip galvanised octogonal pole with round ring arm and 4nos of strong 5feet anchor bolts, templates, and nuts etc.. complete set, 1 hp to 10hp single phase control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 5 hp to 7.5hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 10 hp to 25hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., service charges automati
Tender For nit 313/supply of electrical line materials under oandm head for f.y. 2024-25 under esa, giridih. - electrical items :, danger board 33 kv/11 kv/ lt, led flood outdoor light with ip 66 protection rectangular [100w], male female contact of 33 kv ab switch 600-630 amp., male female contact of 11 kv ab switch 600 amp., male female contact of 11 kv ab switch 400 amp., insulation piercing connector brancing suitable for t joints, spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cabel and three phase connection 1 incoming and out going 3-phase connection as per field requirement, lt phase sepeator, polycarbonate seal bit.specification:-1. anchor type four lock.2. sealing wire should be embaded in female part.3. seal bit should be two part male & female.4. serial no. should be emossed not printed.