Get complete information related to latest Tubular Lug Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tubular Lug Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tubular Lug Tenders.
Tender For improvement of bank colony bishnu rabha path at damodar nagar lokhra from ch 0m to 150m ch 0m to 80m under sopd g for the year 2024 25 providing load bearing drain, e w in subgrade soil gsb wbm iii icbp
Tender For supply of 1 no. 80 mva, 400/11.5/11.5 kv, 3 phase, 3 winding, 50 hz, onan/onaf/ofaf cooled station transformer (without cooler bank) with on load tap changer along ngrs and filled with oil for bellary thermal power station
Tender For provision of power supply infra items for implementation of leh-chushul-thakung itbp link in ba leh. (rate contract for 06 sites) - sub head-i:- (dg set), supply of diesel engine alternator set suitable to generate 5 kva at site conditions, cpcb-iv, totally enclosed diesel engine of suitable to deliver minimum 8.0 bhp (at ntp) , factory assembled and factory tested single/multi cylinder air / water cooled electric start ready to use (rtu) type, housed in a sound proof canopy with manual control panel and coupled with 5 kva single phase, 230 volts alternator at 1500 / 3000 rpm, 0.8 lagging power factor, h-class insulated winding, mounted on rigid ms sheet channel base-frame of sturdy design with necessary reinforcement and with in-built fuel tank of sheet metal, suitable enough for minimum 8 hours running of dg, complete with drain valve, air vent, inlet, outlet connections and gauge. complete with all accessories, battery, engine control panel and having lube oil pressure meter, fuel level gauge, voltmeter, ammeter, frequency meter, engine rpm meter complete as per specifications attached., supplying , installation, testing and commissioning of maintenance free chemical earth station as per latest rdso specifications consisting of :-a) copper bonded steel electrode of 3 meter long, 17 mm dia with copper bonded thickness of minimum 250 microns and ul listed and marked - 1no.b) maintenance free, environmental friendly, mineral compounds, semi soluble , non corrosive , conductivity improving material of rdso approved- 35 kgc) polyplastic , heavy duty, weatherproof, environmetle free earth pit chamber with cover size approx. top dia 250mm, bottom dia 330 mm and height 260 mm heavy duty of 7 ton load capacity, the base unit should have knockouts for interconnecting of strips- 1no., providing and fixing 32 mm x 3 mm g.i. strip direct in ground including digging the trench, laying of strip and refilling the trench, making good the damages, connections etc. as required., supplying installation, testing and commissioning of 32 a rating, double pole, side handle type changeover switch in sheet steel enclosure suitable for operation on 240 v,1-phase, 50 hz ac supply including interconnections , complete as required (bsnl approved makes)., replacement / supplying & laying of 2 x 6 sq mm pvc insulated, pvc sheathed copper conductor armoured cable of 1.1kv grade on surface/wall i/c making connections, testing etc complete as reqd. (isi make), supplying and fixing of fire bucket set( set of 3 buckets) of 9 litre capacity coloured with fire red paint and written "fire on it including supplying and fixing suitable size ms angle iron frame suitable for 3 buckets having hooks etc. including fixing on wall and filling soft sand in buckets complete as required., supplying and fixing of abc type fire extinguishers of 2 kg (abc powder type map-90) complete with delivery hose, squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket complete with installation at site with suitable bracket complete as required (isi), acceptance testing of the 5 kva dg set with initial testing after commissioning of dg set at site for 4 hrs in presence of bsnl representative and final acceptance testing after the initial testing for 8 hours on full load and 1 hour on 10% over load at site as per bsnl a/t performa. all resources (fuel, artificial load arrangement, skilled manpower etc.) required for this acceptance testing shall be arranged by vendor., sub head - ii: ( solar power plant), supplying, installation, testing and commissioning of mono perc solar pv panels for 12.5 kwp solar generation system rating complete as required as per the attached specifications., supplying, installation, testing and commissioning of battery bank of 180 v suitable for 12.5kwp solar pv system comprising of 90 nos.. 2v - 200 ah rating vrla batteries, battery rack, protections, dc distribution board, suitable teflon cabling for interconnections,
Tender For purchase of tool and equipment in electrician trade in various itis under scdd - tool and equipment in electrician trade, contactor & auxillary contacts 3 phase, 415 volt, 25 amp with 2 no and 2 nc, contactor & auxillary contacts 3 phase, 415 volt, 32 amp with 2 no and 2 nc, limit switch - limit switch, liver operated 2a 500v, 2 contacts, rotary switch 16a/440v, relay- a.cut out relay 16a,440v, relay- b.reverse current 16a, 440v, relay- c. over current 16a,440 v, relay- d.under voltage 360v-440v, insulators including hardware fittings - pin type, insulators including hardware fittings - shackle type, insulators including hardware fittings - egg type, insulators including hardware fittings -suspension type, hydrometer, load bank ( lamp/ heater type) 6kw, 3ph, brake test arrangement with two spring balance rating 0 to 25 kg, laboratory type induction coil 1000 w, thermometer -digital 0-150 c, series test lamp 230v, 60w, knife switch dpdt fitted with fuse terminals 16 amp, knife switch tpdt fitted with fuse terminals 16 amp/ 440 v, miniature circuit breaker 16 amp, earth plate - 60cm 60cm 3.15mm copper plate,, earth plate - 60cm 60cm 6mm gi plate, earth electrode- primary electrode 2100 28 3.25mm, secondary cu strip 20 5mm, mccb - 100 amps, triple pole, elcb-25amps, double pole and 25amps, double pole, l n 30 ma, rccb-25amps, double pole and 25amps, double pole, l n 30 ma, fuses - hrc, fuses - glass, fuses - rewire type, rheostat (sliding type) - 0-25 ohm, 2a, rheostat (sliding type) - 0-300 ohm, 2a, rheostat (sliding type) - 0-1 ohm, 10 a, rheostat (sliding type) - 0-10 ohm, 5 a, capacitors - electrolytic, capacitors - ceramic, capacitors - polyester film, capacitors - variable, capacitors -dual run, various electronic components, various lamps - halogen, various lamps - incandescent lamp, various lamps - fluorescent tube, various lamps - hp mercury vapor lamp, various lamps - high pressure sodium lamp, various lamps - low pressure sodium lamp, various lamps - led, plug socket 230v, 5a, piano switch 230v, 5a, lamp holder 230v, 5a, cables:twisted pair, non -metallic sheathed cable, underground feeder cable, ribbon cable, metallic sheathed cable, multi-conductor cable, coaxial cable, direct-buried cable, bus bar with brackets (1 mtr each), rcc pole with accessories (ms angle iron, c-clamp, stay insulator etc.) and materials 6 mtr, safety belt standard quality, ohm meter;series type, 50/2000 ohm analog, ohm meter;shunt type 50/2000 ohm, digital multimeter, a.c voltmeter m.i analog, portable box type housed in bakelite case, milli voltmeter centre zero analog, portable box type housed in bakelite case (100-0-100 mv), ammeter mc analog, portable box type housed in bakelite case - 0- 500 ma, ammeter mc analog, portable box type housed in bakelite case - 0- 5a, ammeter mc analog, portable box type housed in bakelite case - 0- 25a, ac ammeter mi analog, portable box type housed in bakelite case - 0-1a, ac ammeter mi analog, portable box type housed in bakelite case - 0-5a, ac ammeter mi analog, portable box type housed in bakelite case - 0-25a, kilo wattmeter analog, digital wattmeter 230v, 1kw, 50hz, a.c. energy meter-single phase, 10a, 240v induction type, a.c. energy meter-three phase, 15a, 440v induction type, power factor meter digital 440v, 20a, three phase portable box type, frequency meter 45 to 55 hz, magnetic flux meter 0-500 tesla, lux meter- lux meter lcd read out 0.05 t0 7000 lumens with battery, tachometer -analog type-10000 rpm, tachometer -digital photo sensor type-10000 rpm, tong tester/clamp meter 0-100a (digital type), megger -analog -500v, 3- point d.c. starter for 2.5 kw dc motor, 4- point d.c. starter for 2.5 kw dc motor, wheat stone bridge with galvanometer and battery, single phase variable auto transformer 0-270v, 10 amp(air cooled), phase sequencer indicator 3 phase 415v, growler, ac starters: - for a.c motors of 2 to 5 h.p. - a. resistance type starter, ac starters: - for a.c motors of 2 to 5 h.p. dire